北美与英国ICU中低潮气量通气实施不佳:基于电子健康记录的多中心回顾性研究
本研究利用英国与美国多中心电子健康记录ICU数据库,回顾性分析机械通气超过48小时患者中低潮气量通气(LTVV,潮气量<8 mL/kg预测体重)的实施情况及相关因素。结果显示两国ICU中LTVV实施有限,中位潮气量分别为7.48与7.91 mL/kg PBW;身高较矮、BMI>30及女性患者更易接受潮气量>8 mL/kg PBW,且潮气量<8 mL/kg PBW与30天死亡率降低相关。
要点
- 英美ICU中LTVV实施有限,中位潮气量接近8 mL/kg PBW上限。
- 身高<160-165 cm、BMI>30及女性患者更易接受潮气量>8 mL/kg PBW。
- 潮气量<8 mL/kg PBW与30天死亡率降低相关。
核心结论
- 在英国和美国常规临床实践中,低潮气量通气(LTVV)的实施有限。
- 潮气量>8 mL/kg PBW与患者结局较差相关。
研究设计与样本
- 回顾性、多中心研究,使用英国CCHIC和美国eICU-CRD电子健康记录ICU数据库。
- 纳入两个数据库中机械通气>48小时且数据质量适合分析的患者,CCHIC共5,466例,eICU-CRD共7,384例。
主要发现
- 中位潮气量在CCHIC为7.48 mL/kg PBW,在eICU-CRD为7.91 mL/kg PBW。
- 未接受LTVV风险最高的患者身高在CCHIC<160 cm、在eICU-CRD<165 cm。
- BMI>30 kg/m2与中位潮气量>8 mL/kg PBW风险增加相关(CCHIC OR 1.9 [95%CI 1.7-2.13];eICU-CRD OR 1.61 [95%CI 1.49-1.75])。
- 女性与中位潮气量>8 mL/kg PBW风险增加相关(CCHIC OR 2.39 [95%CI 2.16-2.65];eICU-CRD OR 2.29 [95%CI 2.26-2.31])。
- 中位潮气量<8 mL/kg PBW与30天死亡率降低相关(CCHIC cause-specific HR 0.86 [95%CI 0.76-0.97];eICU-CRD cause-specific HR 0.9 [95%CI 0.86-1.00])。
关键数值与推荐
- LTVV定义为潮气量<8 mL/kg预测体重(PBW)。
- CCHIC数据库观察到潮气量随时间显著下降。
临床怎么用
- 临床中应关注身高较矮、肥胖及女性患者,避免潮气量超过8 mL/kg PBW。
- 推广LTVV时需针对高风险人群制定策略以提高依从性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Low tidal volume ventilation (LTVV; < 8 mL/kg predicted body weight [PBW]) is a well-established standard of care associated with improved outcomes. This study used data collated in multicenter electronic health record ICU databases from the United Kingdom and the United States to analyze the use of LTVV in routine clinical practice. RESEARCH QUESTION: What factors are associated with adherence to LTVV in the United Kingdom and North America? STUDY DESIGN: This was a retrospective, multicenter study across the United Kingdom and United States of patients who were mechanically ventilated. METHODS: Factors associated with adherence to LTVV were assessed in all patients in both databases who were mechanically ventilated for > 48 h. We observed trends over time and investigated whether LTVV was associated with patient outcomes (30-day mortality and duration of ventilation) and identified strategies to improve adherence to LTVV. RESULTS: A total of 5,466 (Critical Care Health Informatics Collaborative [CCHIC]) and 7,384 electronic ICU collaborative research database [eICU-CRD] patients were ventilated for > 48 h and had data of suitable quality for analysis. The median tidal volume (VT) values were 7.48 mL/kg PBW (CCHIC) and 7.91 mL/kg PBW (eICU-CRD). The patients at highest risk of not receiving LTVV were shorter than 160 cm (CCHIC) and 165 cm (eICU-CRD). Those with BMI > 30 kg/m2 (CCHIC OR, 1.9 [95% CI, 1.7-2.13]; eICU-CRD OR, 1.61 [95% CI, 1.49-1.75]) and female patients (CCHIC OR, 2.39 [95% CI, 2.16-2.65]; eICU-CRD OR, 2.29 [95% CI, 2.26-2.31]) were at increased risk of having median VT > 8 mL/kg PBW. Patients with median VT < 8 mL/kg PBW had decreased 30-day mortality in the CCHIC database (CCHIC cause-specific hazard ratio, 0.86 [95% CI, 0.76-0.97]; eICU-CRD cause-specific hazard ratio, 0.9 [95% CI, 0.86-1.00]). There was a significant reduction in VT over time in the CCHIC database. INTERPRETATION: There has been limited implementation of LTVV in routine clinical practice in the United Kingdom and the United States. VT > 8 mL/kg PBW was associated with worse patient outcomes.
引用
- Samanta RJ, Ercole A, Harris S, et al. Low Tidal Volume Ventilation Is Poorly Implemented for Patients in North American and United Kingdom ICUs Using Electronic Health Records. Chest. 2023. PMID: 37775039. doi:10.1016/j.chest.2023.09.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。