文献速递哮喘

开发用于哮喘临床实践的小气道功能障碍检测工具

Development of a tool to detect small airways dysfunction in asthma clinical practice.
PubMed 文献 · Eur Respir J · 2023-03-30

本研究基于跨国ATLANTIS研究数据,利用SADT问卷条目、患者特征及呼吸测试构建逻辑回归模型预测哮喘患者小气道功能障碍(SAD)。仅用SADT条目8(静坐或静卧时有时喘息)及年龄、哮喘诊断年龄和BMI即可合理检测SAD(AUC 0.74,LR+ 2.3);加入肺功能(FEV1占预计值百分比)后AUC升至0.87(LR+ 5.0),加入振荡法(5-20Hz电阻差和电抗面积)后AUC达0.96(LR+ 12.8)。

要点

  • 静坐或静卧时喘息、年龄、哮喘诊断年龄和BMI可合理预测SAD(AUC 0.74)。
  • 加肺功能后诊断能力提高(AUC 0.87),加振荡法后进一步提高(AUC 0.96)。
  • 在呼吸测试受限的基层医疗中可仅用问卷和患者特征识别SAD。

核心结论

  • 在呼吸测试有限时,询问静息喘息和几个患者特征可合理识别SAD;在高级医院环境中使用肺功能和振荡法可显著提高准确性。

研究设计与样本

  • 基于跨国ATLANTIS研究数据,使用SADT问卷关键条目和临床信息构建逻辑回归模型预测SAD(较不可能或较可能)。

主要发现

  • SADT条目8「静坐或静卧时有时喘息」联合年龄、哮喘诊断年龄和BMI检测SAD的AUC为0.74,LR+为2.3。
  • 加入肺功能(FEV1占预计值百分比)后AUC为0.87,LR+为5.0。
  • 加入振荡法(5-20Hz电阻差和电抗面积)后AUC为0.96,LR+为12.8。

关键数值与推荐

  • SADT条目8联合年龄、哮喘诊断年龄和BMI的AUC 0.74,LR+ 2.3。
  • 联合肺功能的AUC 0.87,LR+ 5.0。
  • 联合振荡法的AUC 0.96,LR+ 12.8。

临床怎么用

  • 在基层或呼吸测试受限环境中,可通过询问静息喘息及收集年龄、哮喘诊断年龄和BMI来识别SAD。
  • 在高级医院中,使用肺功能和振荡法可更准确识别SAD。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Small airways dysfunction (SAD) in asthma is difficult to measure and a gold standard is lacking. The aim of this study was to develop a simple tool including items of the Small Airways Dysfunction Tool (SADT) questionnaire, basic patient characteristics and respiratory tests available depending on the clinical setting to predict SAD in asthma. METHODS: This study was based on the data of the multinational ATLANTIS (Assessment of Small Airways Involvement in Asthma) study including the earlier developed SADT questionnaire. Key SADT items together with clinical information were now used to build logistic regression models to predict SAD group (less likely or more likely to have SAD). Diagnostic ability of the models was expressed as area under the receiver operating characteristic curve (AUC) and positive likelihood ratio (LR+). RESULTS: SADT item 8, "I sometimes wheeze when I am sitting or lying quietly", and the patient characteristics age, age at asthma diagnosis and body mass index could reasonably well detect SAD (AUC 0.74, LR+ 2.3). The diagnostic ability increased by adding spirometry (percentage predicted forced expiratory volume in 1 s: AUC 0.87, LR+ 5.0) and oscillometry (resistance difference between 5 and 20 Hz and reactance area: AUC 0.96, LR+ 12.8). CONCLUSIONS: If access to respiratory tests is limited (e.g. primary care in many countries), patients with SAD could reasonably well be identified by asking about wheezing at rest and a few patient characteristics. In (advanced) hospital settings patients with SAD could be identified with considerably higher accuracy using spirometry and oscillometry.

来源:Eur Respir J,查看原文。版权归原作者所有。

引用

  1. Kocks J, van der Molen T, Voorham J, et al. Development of a tool to detect small airways dysfunction in asthma clinical practice. Eur Respir J. 2023. PMID: 36517179. doi:10.1183/13993003.00558-2022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。