文献速递肺结节与肺癌

卷积神经网络在孤立性肺结节诊断中的准确性与PET/CT及动态增强CT的比较

Diagnostic Accuracy of a Convolutional Neural Network Assessment of Solitary Pulmonary Nodules Compared With PET With CT Imaging and Dynamic Contrast-Enhanced CT Imaging Using Unenhanced and Contrast-Enhanced CT Imaging.
PubMed 文献 · Chest · 2022-09-08

LCP-CNN在平扫CT上的AUC为0.83,优于动态增强CT的0.76,与PET/CT的0.86相当;增强后AUC略有下降。

要点

  • LCP-CNN平扫CT诊断SPN的AUC为0.83,与PET/CT的0.86等效。
  • LCP-CNN平扫CT的AUC优于动态增强CT的0.76。
  • 增强扫描可使LCP-CNN的AUC小幅下降,仅240秒后差异有统计学意义。

核心结论

  • LCP-CNN算法在孤立性肺结节诊断中提供的AUC与PET/CT成像等效。

研究设计与样本

  • 研究为单发肺结节研究(SPN Investigator)的事后分析,该试验为前瞻性多中心研究,比较动态增强CT与PET成像对SPN的诊断准确性。
  • LCP-CNN在外部队列中设计并验证,从动态增强CT的非增强和增强扫描图像生成风险评分,金标准为组织学分析或2年随访。

临床怎么用

  • 对于8-30mm的孤立性肺结节,LCP-CNN可基于平扫CT提供与PET/CT相当的恶性风险预测,有望减少额外检查。
  • 增强扫描可能小幅降低LCP-CNN的诊断准确性,临床应用中可优先考虑平扫CT图像。

局限性

  • 本研究为事后分析,结果需在前瞻性研究中进一步验证。
  • LCP-CNN在外部队列中设计并验证,但本研究中的性能表现仍需外部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Solitary pulmonary nodules (SPNs) measuring 8 to 30 mm in diameter require further workup to determine the likelihood of malignancy. RESEARCH QUESTION: What is the diagnostic performance of a lung cancer prediction convolutional neural network (LCP-CNN) in SPNs using unenhanced and contrast-enhanced CT imaging compared with the current clinical workup? STUDY DESIGN AND METHODS: This was a post hoc analysis of the Single Pulmonary Nodule Investigation: Accuracy and Cost-Effectiveness of Dynamic Contrast Enhanced Computed Tomography in the Characterisation of Solitary Pulmonary Nodules trial, a prospective multicenter study comparing the diagnostic accuracy of dynamic contrast-enhanced (DCE) CT imaging with PET imaging in SPNs. The LCP-CNN was designed and validated in an external cohort. LCP-CNN-generated risk scores were created from the noncontrast and contrast-enhanced CT scan images from the DCE CT imaging. The gold standard was histologic analysis or 2 years of follow-up. The area under the receiver operating characteristic curves (AUC) were calculated using LCP-CNN score, maximum standardized uptake value, and DCE CT scan maximum enhancement and were compared using the DeLong test. RESULTS: Two hundred seventy participants (mean ± SD age, 68.3 ± 8.8 years; 49% women) underwent PET with CT scan imaging and DCE CT imaging with CT scan data available centrally for LCP-CNN analysis. The accuracy of the LCP-CNN on the noncontrast images (AUC, 0.83; 95% CI, 0.79-0.88) was superior to that of DCE CT imaging (AUC, 0.76; 95% CI, 0.69-0.82; P = .03) and equal to that of PET with CT scan imaging (AUC, 0.86; 95% CI, 0.81-0.90; P = .35). The presence of contrast resulted in a small reduction in diagnostic accuracy, with the AUC falling from 0.83 (95% CI, 0.79-0.88) on the noncontrast images to 0.80 to 0.83 after contrast (P < .05 for 240 s after contrast only). INTERPRETATION: An LCP-CNN algorithm provides an AUC equivalent to PET with CT scan imaging in the diagnosis of solitary pulmonary nodules. TRIAL REGISTRATION: ClinicalTrials.gov Identifier; No.: NCT02013063.

来源:Chest,查看原文。版权归原作者所有。

引用

  1. Weir-McCall JR, Debruyn E, Harris S, et al. Diagnostic Accuracy of a Convolutional Neural Network Assessment of Solitary Pulmonary Nodules Compared With PET With CT Imaging and Dynamic Contrast-Enhanced CT Imaging Using Unenhanced and Contrast-Enhanced CT Imaging. Chest. 2022. PMID: 36087795. doi:10.1016/j.chest.2022.08.2227

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。