呼气末与动脉二氧化碳分压比值指导静脉-静脉体外膜氧合撤机
本研究探讨基于二氧化碳消除的指标预测静脉-静脉体外膜氧合(VV-ECMO)撤机准备情况。多中心研究包括生理队列(n=26)和临床队列(n=638),撤机失败率分别为42%和37%。撤机失败主要原因是高吸气努力或呼吸频率,失败者消除单位容积CO2的用力加倍,呼气末与动脉二氧化碳分压比值(PetCO2/PaCO2)与撤机结局强相关。
要点
- VV-ECMO撤机失败主要因高吸气努力或呼吸频率,而非CO2消除总量不足。
- 撤机失败者消除单位容积CO2的用力是成功者的两倍,生理死腔更高。
- PetCO2/PaCO2比值越高,VV-ECMO成功撤机可能性越大。
核心结论
- VV-ECMO撤机失败的主要原因是消除CO2的用力过高,而非CO2消除总量不足。
- 较高的PetCO2/PaCO2比值与更大的VV-ECMO撤机成功可能性相关。
研究设计与样本
- 多中心研究,纳入接受VV-ECMO的严重急性呼吸窘迫综合征机械通气成人。
- 包括前瞻性干预性生理队列(n=26)和回顾性临床队列(n=638)。
主要发现
- 临床队列和生理队列的撤机失败率分别为37%和42%。
- 生理队列中撤机失败的主要原因是高吸气努力或呼吸频率。
- 撤机失败者消除单位容积CO2的用力为68.9(42.4-123)cm H2O/[L/min],成功者为39(20.1-57)cm H2O/[L/min],P=0.007。
- 撤机失败者生理死腔为68(58.73)%,成功者为54(41.64)%,P=0.012。
- 基线PetCO2/PaCO2比值预测撤机结局的ROC曲线下面积为0.87(95%CI 0.71-1)。
关键数值与推荐
- 临床队列中,撤机试验前PetCO2/PaCO2比值与撤机结局相关,OR=4.14(95%CI 1.32-12.2),P=0.015。
- 临床队列中,扫气流量为零时PetCO2/PaCO2比值与撤机结局相关,OR=13.1(95%CI 4-44.4),P<0.001。
临床怎么用
- 可考虑使用PetCO2/PaCO2比值辅助评估VV-ECMO患者撤机准备情况。
- 撤机评估时应关注患者呼吸努力和呼吸频率,而不仅依赖氧合指标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Rationale: Weaning from venovenous extracorporeal membrane oxygenation (VV-ECMO) is based on oxygenation and not on carbon dioxide elimination. Objectives: To predict readiness to wean from VV-ECMO. Methods: In this multicenter study of mechanically ventilated adults with severe acute respiratory distress syndrome receiving VV-ECMO, we investigated a variable based on CO2 elimination. The study included a prospective interventional study of a physiological cohort (n = 26) and a retrospective clinical cohort (n = 638). Measurements and Main Results: Weaning failure in the clinical and physiological cohorts were 37% and 42%, respectively. The main cause of failure in the physiological cohort was high inspiratory effort or respiratory rate. All patients exhaled similar amounts of CO2, but in patients who failed the weaning trial, [Formula: see text]e was higher to maintain the PaCO2 unchanged. The effort to eliminate one unit-volume of CO2, was double in patients who failed (68.9 [42.4-123] vs. 39 [20.1-57] cm H2O/[L/min]; P = 0.007), owing to the higher physiological Vd (68 [58.73] % vs. 54 [41.64] %; P = 0.012). End-tidal partial carbon dioxide pressure (PetCO2)/PaCO2 ratio was a clinical variable strongly associated with weaning outcome at baseline, with area under the receiver operating characteristic curve of 0.87 (95% confidence interval [CI], 0.71-1). Similarly, the PetCO2/PaCO2 ratio was associated with weaning outcome in the clinical cohort both before the weaning trial (odds ratio, 4.14; 95% CI, 1.32-12.2; P = 0.015) and at a sweep gas flow of zero (odds ratio, 13.1; 95% CI, 4-44.4; P < 0.001). Conclusions: The primary reason for weaning failure from VV-ECMO is high effort to eliminate CO2. A higher PetCO2/PaCO2 ratio was associated with greater likelihood of weaning from VV-ECMO.
引用
- Lazzari S, Romitti F, Busana M, et al. End-Tidal to Arterial Pco2 Ratio as Guide to Weaning from Venovenous Extracorporeal Membrane Oxygenation. Am J Respir Crit Care Med. 2022. PMID: 35608503. doi:10.1164/rccm.202201-0135OC
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。