多平面上气道手术治疗阻塞性睡眠呼吸暂停对内型的影响及预测手术结局的效用
该前瞻性研究纳入23例OSA患者,在多平面上气道手术前后进行临床及研究PSG,测量AHI与四种内型。术后AHI总显著下降,但各内型无显著变化,仅塌陷性呈大幅可变改善,且塌陷性改善与AHI改善强相关;基线内型均不能预测手术反应。
要点
- 多平面上气道手术可降低OSA患者AHI,但对非解剖内型无显著影响。
- 术后上气道塌陷性改善幅度大且变异大,并与AHI改善强相关。
- 基线OSA内型不能预测手术反应。
核心结论
- 手术不可预测地改变上气道塌陷性,但不改变非解剖内型。
- 没有基线内型可预测手术反应。
研究设计与样本
- 前瞻性研究,纳入23例OSA患者,在多平面上气道手术前及术后≥3个月进行临床及研究PSG。
- 内型在仰卧位非快速眼动期测量,数值以均数±标准差或中位数(四分位距)表示。
主要发现
- 手术降低AHI总:38.7(23.4–79.2)次/h vs. 22.0(13.3–53.5)次/h;p=0.009。
- OSA各内型无显著变化,但塌陷性呈大幅可变改善:CPAP降阶法∆1.9±4.9 L/min,p=0.09,n=21;PSG法∆3.4(-2.8–49.0)%Veupnoea,p=0.06,n=20。
- 塌陷性改善与AHI改善强相关(%∆AHISupineNREM vs. ∆collapsibility:p<0.005;R2=0.46–0.48)。
- 基线OSA内型均不能预测手术反应。
临床怎么用
- 多平面上气道手术可考虑用于不能耐受CPAP的OSA患者以降低AHI。
- 术前内型检测暂不能用于筛选手术应答者。
局限性
- 样本量小(23例),部分内型测量例数不足(n=20–21)。
- 术后评估时间≥3个月,未报告更长随访。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVE: Upper airway surgery for obstructive sleep apnoea (OSA) is an alternative treatment for patients who are intolerant of continuous positive airway pressure (CPAP). However, upper airway surgery has variable treatment efficacy with no reliable predictors of response. While we now know that there are several endotypes contributing to OSA (i.e., upper airway collapsibility, airway muscle response/compensation, respiratory arousal threshold and loop gain), no study to date has examined: (i) how upper airway surgery affects all four OSA endotypes, (ii) whether knowledge of baseline OSA endotypes predicts response to surgery and (iii) whether there are any differences when OSA endotypes are measured using the CPAP dial-down or clinical polysomnographic (PSG) methods. METHODS: We prospectively studied 23 OSA patients before and ≥3 months after multilevel upper airway surgery. Participants underwent clinical and research PSG to measure OSA severity (apnoea-hypopnoea index [AHI]) and endotypes (measured in supine non-rapid eye movement [NREM]). Values are presented as mean ± SD or median (interquartile range). RESULTS: Surgery reduced the AHITotal (38.7 [23.4 to 79.2] vs. 22.0 [13.3 to 53.5] events/h; p = 0.009). There were no significant changes in OSA endotypes, however, large but variable improvements in collapsibility were observed (CPAP dial-down method: ∆1.9 ± 4.9 L/min, p = 0.09, n = 21; PSG method: ∆3.4 [-2.8 to 49.0]%Veupnoea , p = 0.06, n = 20). Improvement in collapsibility strongly correlated with improvement in AHI (%∆AHISupineNREM vs. ∆collapsibility: p < 0.005; R2 = 0.46-0.48). None of the baseline OSA endotypes predicted response to surgery. CONCLUSION: Surgery unpredictably alters upper airway collapsibility but does not alter the non-anatomical endotypes. There are no baseline predictors of response to surgery.
引用
- Wong AM, Landry SA, Joosten SA, et al. Examining the impact of multilevel upper airway surgery on the obstructive sleep apnoea endotypes and their utility in predicting surgical outcomes. Respirology. 2022. PMID: 35598093. doi:10.1111/resp.14280
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。