肺保护性通气中反向触发不同步对膈肌功能的影响:实验模型
研究通过猪肺损伤模型,建立反向触发不同步(RT)并评估其对膈肌结构与功能的影响。结果显示,高呼吸努力的RT与膈肌功能受损相关,而低呼吸努力的RT则与膈肌力量保留相关。
要点
- 高呼吸努力的RT可导致膈肌功能受损及异常肌纤维比例增加。
- 低呼吸努力的RT与膈肌力量保留相关。
- RT的呼吸努力程度在动物间差异很大,1:1同步模式最常见。
核心结论
- 在可重复的RT动物模型中,高呼吸努力的RT与膈肌功能受损相关,而低呼吸努力的RT与膈肌力量保留相关。
研究设计与样本
- 32头通气猪通过表面活性物质耗竭和高应力通气诱导肺损伤,随后分为被动机械通气组(Vt 10 ml/kg,RR 30-35次/分,n=8)和更肺保护性策略组(Vt 6-8 ml/kg,n=24),调整RR以促进RT发生并持续3小时。
- 评估膈肌功能(膈神经刺激下的经膈压[Pdi]力/频率曲线)和结构(活检)。
主要发现
- 与被动通气相比,发生RT的保护性通气组接受显著更低的Vt(7 vs. 10 ml/kg)和更高的RR(45 vs. 31次/分)。
- 1:1同步模式在83%的动物中最常见。
- RT诱导的呼吸努力在动物间高度可变。
- 最低三分位呼吸努力的RT与被动通气相比,单收缩Pdi高23%。
- 高呼吸努力的RT与单收缩Pdi低10%及异常肌纤维比例更高相关。
临床怎么用
- 临床中应关注反向触发的呼吸努力程度,高努力可能损害膈肌功能,需个体化调整通气策略。
局限性
- 本研究为动物模型,结果需在临床研究中进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Rationale: Reverse triggering dyssynchrony (RT) is a patient-ventilator interaction where a respiratory muscle contraction is triggered by a passive mechanical insufflation. Its impact on diaphragm structure and function is unknown. Objectives: To establish an animal model of RT with lung injury receiving lung-protective ventilation and to assess its impact on the structure and function of the diaphragm. Methods: Lung injury was induced by surfactant depletion and high-stress ventilation in 32 ventilated pigs. Animals were allocated to receive passive mechanical ventilation (Vt: 10 ml/kg; respiratory rate [RR]: 30-35 breaths/min; n = 8) or a more lung-protective strategy (Vt: 6-8 ml/kg; n = 24) with adjustments in RR to facilitate the occurrence of RT for 3 hours. Diaphragm function (transdiaphragmatic pressure [Pdi] during phrenic nerve stimulation [force/frequency curve]) and structure (biopsies) were assessed. The impact of RT on diaphragm function was analyzed according to the breathing effort assessed by the pressure-time product. Measurements and Main Results: Compared with passive ventilation, the protective ventilation group with RT received significantly lower Vt (7 vs. 10 ml/kg) and higher RR (45 vs. 31 breaths/min). An entrainment pattern of 1:1 was the most frequently occurring in 83% of the animals. Breathing effort induced by RT was highly variable across animals. RT with the lowest tercile of breathing effort was associated with 23% higher twitch Pdi compared with passive ventilation, whereas RT with high breathing effort was associated with a 10% lower twitch Pdi and a higher proportion of abnormal muscle fibers. Conclusions: In a reproducible animal model of RT with variable levels of breathing effort and entrainment patterns, RT with high effort is associated with impaired diaphragm function, whereas RT with low effort is associated with preserved diaphragm force.
引用
- Damiani LF, Engelberts D, Bastia L, et al. Impact of Reverse Triggering Dyssynchrony during Lung-Protective Ventilation on Diaphragm Function: An Experimental Model. Am J Respir Crit Care Med. 2022. PMID: 34941477. doi:10.1164/rccm.202105-1089OC
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。