社区获得性肺炎入院嗜酸性粒细胞计数与住院资源使用的前瞻性多中心研究
该前瞻性多中心队列研究纳入德国≥18岁社区获得性肺炎(CAP)患者,评估入院血嗜酸性粒细胞计数与ICU入住、机械通气及住院时长的关联。结果显示较低嗜酸性粒细胞计数与ICU入住增加(P<.001)、机械通气率升高(P=.014)及住院时间延长(P=.024)相关;以10 cells/μL为阈值,嗜酸性粒细胞减少(≤10 cells/μL)者ICU入住率14.2% vs 8.5%(P<.001;调整OR 1.78)、机械通气率9.1% vs 5.2%(P=.003;调整OR 1.82)及平均住院10.2天 vs 9.0天(P=.013)均更高。
要点
- 入院嗜酸性粒细胞减少(≤10 cells/μL)与CAP患者ICU入住和机械通气风险升高独立相关。
- 嗜酸性粒细胞计数或可作为CAP住院资源规划的实用生物标志物。
核心结论
- 入院嗜酸性粒细胞减少(≤10 cells/μL)与CAP患者更高的ICU入住率、机械通气率及更长住院时间相关,可能作为医疗资源规划的实用生物标志物。
研究设计与样本
- 前瞻性多中心队列研究(CAPNETZ,注册号2024-07-11-CHV6),自2017年起在德国大学医院纳入≥18岁CAP患者。
- 采用多变量回归模型评估入院血嗜酸性粒细胞计数与ICU入住、机械通气及住院时长的关联,并确定最佳阈值。
主要发现
- 较低嗜酸性粒细胞计数与ICU入住增加相关(n=1,639;P<.001),在全身糖皮质激素治疗患者(P=.002)及未接受糖皮质激素患者(P=.047)中均显著。
- 较低嗜酸性粒细胞计数与机械通气率升高(P=.014)及住院时间延长(P=.024)相关。
- 嗜酸性粒细胞减少(≤10 cells/μL)者ICU入住率14.2% vs 8.5%(P<.001;调整OR 1.78)。
- 嗜酸性粒细胞减少者机械通气率9.1% vs 5.2%(P=.003;调整OR 1.82),平均住院10.2天 vs 9.0天(P=.013)。
关键数值与推荐
- 嗜酸性粒细胞计数阈值10 cells/μL被确定为区分ICU入住和机械通气风险高低的最佳 cutoff。
- 嗜酸性粒细胞减少定义为≤10 cells/μL,该组ICU入住调整OR 1.78、机械通气调整OR 1.82。
临床怎么用
- 对CAP入院患者可考虑检测血嗜酸性粒细胞计数,≤10 cells/μL提示需关注ICU入住和机械通气风险及住院资源需求。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Eosinopenia has been associated with adverse outcomes in community-acquired pneumonia (CAP). However, its relationship with hospital resource use remains unclear. RESEARCH QUESTION: What is the association between admission eosinophil counts and hospital resource use among adults with CAP? STUDY DESIGN AND METHODS: This prospective multicenter cohort study (Community-Acquired Pneumonia Network of Competence [CAPNETZ]; Identifier: 2024-07-11-CHV6) has enrolled patients ≥ 18 years of age with CAP in university hospitals in Germany since 2017. Associations between admission blood eosinophil counts and hospital resource use-ICU admission, mechanical ventilation, and length of stay-were assessed using multivariable regression models. The optimal eosinophil count threshold for stratifying patients by ICU admission and mechanical ventilation rates was identified, and outcomes were compared between patients above and below this threshold. RESULTS: Lower eosinophil counts at admission were associated with increased ICU admission (n = 1,639; P < .001), including among patients treated with systemic glucocorticoids (P = .002) and those not receiving glucocorticoids (P = .047). Lower eosinophil counts also were associated with higher rates of mechanical ventilation (P = .014) and longer hospital stays (P = .024). An eosinophil count threshold of 10 cells/μL was identified as the cutoff that best distinguished patients with higher vs lower risk of ICU admission and mechanical ventilation. Patients with eosinopenia (≤ 10 cells/μL) showed higher ICU admission rates (14.2% vs 8.5%; P < .001; adjusted OR, 1.78), increased mechanical ventilation rates (9.1% vs 5.2%; P = .003; adjusted OR, 1.82), and longer hospitalization (mean, 10.2 days vs 9.0 days; P = .013). INTERPRETATION: Our results show that admission eosinopenia (≤ 10 cells/μL) was associated with greater hospital resource use and may serve as a practical biomarker for health care resource planning. CLINICAL TRIAL REGISTRATION: German Clinical Trials Register; No.: DRKS00005274; URL: https://drks.de/.
引用
- Weckler, Wu, Bertrams, et al. Association Between Admission Eosinophil Count and Hospital Resource Use in Community-Acquired Pneumonia: A Prospective Multicenter Study. Chest. 2026. PMID: 41933608. doi:10.1016/j.chest.2026.03.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。