入院嗜酸性粒细胞计数与社区获得性肺炎住院资源使用的关系
这项前瞻性多中心队列研究纳入德国≥18岁社区获得性肺炎(CAP)患者,分析入院血嗜酸性粒细胞计数与ICU入住、机械通气及住院时长的关联。结果显示嗜酸性粒细胞减少(≤10 cells/μL)与更高ICU入住率、机械通气率及更长住院时间相关,提示其可作为医疗资源规划的实用生物标志物。
要点
- 入院嗜酸性粒细胞≤10 cells/μL者ICU入住率14.2%对8.5%,校正OR 1.78。
- 该阈值者机械通气率9.1%对5.2%,校正OR 1.82;住院均值10.2天对9.0天。
- 嗜酸性粒细胞减少与资源使用增加相关,可辅助住院资源规划。
核心结论
- 入院嗜酸性粒细胞减少(≤10 cells/μL)与CAP患者更高的住院资源使用相关,可能作为医疗资源规划的实用生物标志物。
研究设计与样本
- 前瞻性多中心队列研究(CAPNETZ,注册号2024-07-11-CHV6),自2017年起在德国大学医院纳入≥18岁CAP患者。
- 采用多变量回归模型评估入院血嗜酸性粒细胞计数与ICU入住、机械通气及住院时长的关联,并识别最佳分层阈值。
主要发现
- 较低入院嗜酸性粒细胞计数与ICU入住增加相关(n=1,639;P<.001),在全身糖皮质激素治疗者(P=.002)和未使用者(P=.047)中均存在。
- 较低嗜酸性粒细胞计数还与更高机械通气率(P=.014)和更长住院时间(P=.024)相关。
- 嗜酸性粒细胞≤10 cells/μL者ICU入住率14.2%对8.5%(P<.001;校正OR 1.78)。
- 该组机械通气率9.1%对5.2%(P=.003;校正OR 1.82),住院均值10.2天对9.0天(P=.013)。
关键数值与推荐
- ICU入住与机械通气风险分层的最佳嗜酸性粒细胞阈值为10 cells/μL。
- 嗜酸性粒细胞减少定义为≤10 cells/μL。
临床怎么用
- 对CAP入院患者可参考嗜酸性粒细胞计数≤10 cells/μL识别ICU入住和机械通气风险较高者,辅助医疗资源规划。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Chest . 2026 Aug;170(2):353-364. doi: 10.1016/j.chest.2026.03.018. Epub 2026 Mar 31. ABSTRACT BACKGROUND: Eosinopenia has been associated with adverse outcomes in community-acquired pneumonia (CAP). However, its relationship with hospital resource use remains unclear. RESEARCH QUESTION: What is the association between admission eosinophil counts and hospital resource use among adults with CAP? STUDY DESIGN AND METHODS: This prospective multicenter cohort study (Community-Acquired Pneumonia Network of Competence [CAPNETZ]; Identifier: 2024-07-11-CHV6) has enrolled patients ≥ 18 years of age with CAP in university hospitals in Germany since 2017. Associations between admission blood eosinophil counts and hospital resource use-ICU admission, mechanical ventilation, and length of stay-were assessed using multivariable regression models. The optimal eosinophil count threshold for stratifying patients by ICU admission and mechanical ventilation rates was identified, and outcomes were compared between patients above and below this threshold. RESULTS: Lower eosinophil counts at admission were associated with increased ICU admission (n = 1,639; P < .001), including among patients treated with systemic glucocorticoids (P = .002) and those not receiving glucocorticoids (P = .047). Lower eosinophil counts also were associated with higher rates of mechanical ventilation (P = .014) and longer hospital stays (P = .024). An eosinophil count threshold of 10 cells/μL was identified as the cutoff that best distinguished patients with higher vs lower risk of ICU admission and mechanical ventilation. Patients with eosinopenia (≤ 10 cells/μL) showed higher ICU admission rates (14.2% vs 8.5%; P < .001; adjusted OR, 1.78), increased mechanical ventilation rates (9.1% vs 5.2%; P = .003; adjusted OR, 1.82), and longer hospitalization (mean, 10.2 days vs 9.0 days; P = .013). INTERPRETATION: Our results show that admission eosinopenia (≤ 10 cells/μL) was associated with greater hospital resource use and may serve as a practical biomarker for health care resource planning. CLINICAL TRIAL REGISTRATION: German Clinical Trials Register; No.: DRKS00005274; URL: https://drks.de/. PMID: 41933608 | PMC: PMC13494433 | DOI: 10.1016/j.chest.2026.03.018
引用
- PubMed 顶刊 · 肺炎:Association Between Admission Eosinophil Count and Hospital Resource Use in Community-Acquired Pneumonia: A Prospective Multicenter Study
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。