文献速递肺结节与肺癌

混合现实与CT引导术前钩丝定位肺结节在VATS中的非劣效随机试验

Comparison of mixed reality and computed tomography-guided preoperative hook-wire localization for pulmonary nodules in video-assisted thoracoscopic surgery: a noninferiority randomized clinical trial
RSS 订阅 · PubMed 高证据 · 肺结节与肺癌筛查 · 2026-04-02

这项前瞻性单中心非劣效随机临床试验纳入90例小肺结节患者,比较混合现实(MR)引导与CT引导术前定位的准确性、效率和安全性。MR组定位总偏差更小(5.50 mm vs. 6.84 mm,p=0.04),操作时间更短(3.98 min vs. 10.73 min,p<0.001),穿刺次数更少(1.05 vs. 2.28,p<0.001),辐射暴露更低(p<0.001)。MR引导定位在准确性和总体安全性上达到非劣效标准,并显示操作效率和辐射暴露的探索性临床获益。

要点

  • MR引导肺结节术前定位在准确性上非劣于CT引导,且总偏差更小。
  • MR组操作时间和穿刺次数显著少于CT组,辐射暴露更低。
  • 两组并发症率和手术结局相当,支持MR作为安全有效的替代方案。

核心结论

  • MR引导定位在定位准确性和总体安全性上达到对CT引导的非劣效标准。
  • MR引导定位显示操作效率提高和辐射暴露减少的探索性临床获益。

研究设计与样本

  • 前瞻性、单中心、非劣效随机临床试验,纳入90例小肺结节患者。
  • 患者随机分为MR引导定位组和CT引导定位组,进行意向性(ITT)和符合方案(PP)分析。

主要发现

  • MR组定位总偏差显著更小(5.50 mm vs. 6.84 mm,p=0.04),垂直偏差也更小(p=0.04)。
  • MR组操作时间显著缩短(3.98 min vs. 10.73 min,p<0.001),穿刺次数显著减少(1.05 vs. 2.28,p<0.001)。
  • MR组CT扫描次数、剂量长度乘积和有效剂量均更低(p<0.001)。
  • 气胸和出血等并发症率在MR组略低,但无统计学显著性,手术结局两组相当。

关键数值与推荐

  • 主要结局为定位准确性,以偏离目标结节的偏差衡量。
  • 非劣效性检验基于定位准确性和总体安全性。

临床怎么用

  • 对于VATS术前肺结节定位,MR引导可作为CT引导的安全有效替代方案。
  • MR引导可能减少操作时间、穿刺次数和辐射暴露,但需结合中心设备和经验选择。

局限性

  • 单中心研究,样本量90例,结果外推需谨慎。
  • 并发症率差异无统计学显著性,安全性优势需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Sci Rep. 2026 Apr 2;16(1):15690. doi: 10.1038/s41598-026-47315-x. ABSTRACT Preoperative localization of pulmonary nodules is critical for video-assisted thoracoscopic surgery (VATS). Traditional Computed Tomography (CT)-guided localization has limitations, including radiation exposure and procedural complexity. Mixed Reality (MR)-guided localization offers a promising alternative, potentially improving accuracy, efficiency, and safety. To compare the accuracy, efficiency, and safety of MR-guided versus CT-guided preoperative localization for pulmonary nodules in VATS through a noninferiority randomized trial. This prospective, single-center, noninferiority randomized clinical trial enrolled 90 patients with small pulmonary nodules. Patients were randomized to either MR-guided or CT-guided localization groups. The primary outcome was localization accuracy, measured by deviation from the target nodule. Secondary outcomes included procedural duration, insertion attempts, radiation exposure, complications, and surgical outcomes. Intention-to-treat (ITT) and per-protocol (PP) analyses were both performed. The MR-guided group demonstrated significantly higher localization accuracy, with smaller total deviation (5.50 mm vs. 6.84 mm, p = 0.04) and vertical deviation (p = 0.04). Procedural duration (3.98 min vs. 10.73 min, p < 0.001) and insertion attempts (1.05 vs. 2.28, p < 0.001) were significantly reduced in the MR-guided group. Radiation exposure was also lower, with fewer CT scans and reduced dose length product and effective dose (p < 0.001). Complication rates, including pneumothorax and hemorrhage, were slightly lower in the MR-guided group but not statistically significant. Surgical outcomes were comparable between groups. MR-guided localization met the noninferiority criteria to CT-guided localization in terms of localization accuracy and overall safety, and showed exploratory clinical benefits with notably improved procedural efficiency and reduced radiation exposure. These findings support its potential as a safe and effective alternative for preoperative pulmonary nodule localization in thoracic surgery. PMID: 41927720 | PMC: PMC13187415 | DOI: 10.1038/s41598-026-47315-x

来源:PubMed 高证据 · 肺结节与肺癌筛查,查看原文。版权归原作者所有。

引用

  1. PubMed 高证据 · 肺结节与肺癌筛查:Comparison of mixed reality and computed tomography-guided preoperative hook-wire localization for pulmonary nodules in video-assisted thoracoscopic surgery: a noninferiority randomized clinical trial

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。