前穹窿/宫颈区定量血流与胎盘植入及术中出血的关系
本研究为前瞻性研究,纳入117例因前壁前置胎盘疑似胎盘植入(PAS)转诊的患者,采用经阴道彩色多普勒超声对前穹窿/宫颈(AFC)区进行定量血流(QV)分析。结果显示QV≥8.5%可较好识别PAS及严重术中出血,但阴性预测值有限。该定量指标有助于PAS的临床管理和手术规划。
要点
- AFC区QV≥8.5%与PAS、穿透性胎盘植入及严重术中出血风险增加相关。
- QV对PAS的AUC为0.821,特异度89.7%,但阴性预测值仅50.0%。
- QV值不用于临床决策,仅作为辅助评估工具。
核心结论
- AFC区QV≥8.5%可识别PAS及严重术中出血高风险患者,但阴性预测值有限。
研究设计与样本
- 采用标准化设置的经阴道彩色多普勒超声,在正中矢状面显示宫颈和子宫下段,对AFC区进行QV分析。
主要发现
- 117例患者中89例(76.1%)经组织病理学确诊PAS,其中粘连性11例、植入性55例、穿透性23例。
- 109例获得可靠术中出血量估计,53例(48.6%)发生严重术中出血(>1500 mL)。
- QV区分有无PAS的AUC为0.821(95% CI,0.739-0.886)。
- QV≥8.5%时敏感度70.5%(95% CI,59.8-79.7%),特异度89.7%(95% CI,68.3-96.1%),阳性预测值93.9%(95% CI,86.1-97.5%),阴性预测值50.0%(95% CI,40.3-57.8%)。
关键数值与推荐
- QV最佳截断值为8.5%,即AFC区彩色像素百分比的均值。
- QV≥8.5%与PAS的OR为14.9(95% CI,4.7-47.0;P<0.0001)。
- QV≥8.5%与穿透性胎盘植入的OR为55.5(95% CI,10.1-305.7;P<0.0001)。
- QV≥8.5%与严重术中出血的OR为3.9(95% CI,1.8-8.7;P=0.0009),与输注≥4单位血制品的OR为4.6(95% CI,2.0-10.4;P=0.0002)。
临床怎么用
- 对疑似PAS患者,经阴道彩色多普勒超声测量AFC区QV可作为风险评估的辅助手段。
- QV≥8.5%提示PAS及严重术中出血风险升高,可为手术规划和多学科准备提供参考。
- QV阴性结果不能可靠排除PAS,仍需结合其他超声特征综合判断。
局限性
- QV阴性预测值仅50.0%,排除PAS的能力有限。
- QV值未提供给临床医生,未用于临床决策,尚缺乏其直接指导临床的验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: We aimed to evaluate a quantitative method for analyzing vascularization in the anterior fornix/cervix (AFC) region in women at risk of placenta accreta spectrum (PAS). The primary aim was to evaluate the association between quantitative vascularization (QV) and severity of PAS (determined by histopathology) and to estimate the optimal QV cut-off value to predict PAS. A secondary aim was to evaluate the association of QV with severe intraoperative blood loss (IOBL). METHODS: This was a prospective study including patients with anterior placenta previa referred for suspected PAS at the University of Texas Health Science Center at Houston, TX, USA, between December 2021 and June 2025. Transvaginal ultrasound with color Doppler (with standardized settings) was performed to visualize the cervix and the lower uterine segment in the midsagittal plane. The prenatal diagnosis of high risk for PAS was based on ultrasound features including loss of the uteroplacental interface, the presence of placental lacunae, increased vascularization and abnormal bladder wall. For QV assessment, a videoclip was acquired, in which the AFC region was defined and post-processing analysis was used to estimate the percentage of color pixels within the AFC region in each frame. The mean value across all frames was defined as the QV value. QV values were not provided to clinicians and were not used for clinical decisions. Associations between QV and PAS, depth of implantation, IOBL and units of blood products transfused were evaluated, as well as the ability of QV to discriminate between patients with and those without PAS. RESULTS: A total of 117 patients were included. PAS was confirmed histopathologically in 89 (76.1%) patients (placenta accreta, n = 11; placenta increta, n = 55; placenta percreta, n = 23). A reliable estimation of IOBL was obtained in 109 patients and severe IOBL (> 1500 mL) occurred in 53 (48.6%) of these cases. The area under the receiver-operating-characteristics curve, demonstrating the ability of QV to discriminate between cases with and those without confirmed PAS, was 0.821 (95% CI, 0.739-0.886). The optimal QV cut-off value was 8.5%, yielding a sensitivity of 70.5% (95% CI, 59.8-79.7%), specificity of 89.7% (95% CI, 68.3-96.1%), positive predictive value of 93.9% (95% CI, 86.1-97.5%) and negative predictive value of 50.0% (95% CI, 40.3-57.8%). QV ≥ 8.5% was associated with increased odds of PAS (odds ratio (OR), 14.9 (95% CI, 4.7-47.0); P < 0.0001), placenta percreta (OR, 55.5 (95% CI, 10.1-305.7); P < 0.0001), severe IOBL (OR, 3.9 (95% CI, 1.8-8.7); P = 0.0009) and the need for ≥ 4 units of blood products during delivery (OR, 4.6 (95% CI, 2.0-10.4); P = 0.0002). CONCLUSION: QV ≥ 8.5% of the AVC region identifies patients at increased risk for PAS and for severe IOBL. Although the negative predictive value was limited, QV assessment of the AFC region may provide valuable information to support clinical management and surgical planning in PAS. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.