文献速递产科母胎医学

人工智能实时辅助胎儿畸形超声筛查的新模式探索

Exploring a new paradigm for the fetal anomaly ultrasound scan: Artificial intelligence in real time.
PubMed 文献 · Prenat Diagn · 2021-10-18

AI辅助每次扫描平均节省7.62分钟(34.7%,p<0.0001),两种方法生物测量无临床显著差异,AI工具保存满意切面的比例在仅四个核心切面时为93%、全部13个切面时为73%。

要点

  • AI辅助中孕期筛查超声平均每次节省7.62分钟(34.7%),报告时间无差异。
  • 两种方法生物测量无临床显著差异,AI工具在四个核心切面满意切面保存率为93%。
  • AI工具通过移除干扰性任务帮助超声医师集中精力于图像解读。

核心结论

  • 将自由手扫描与图像采集和测量分离可实现更快的扫描并改变工作流程。
  • 移除重复性任务可能使更多注意力转向识别胎儿畸形。
  • 需进一步改进图像平面检测算法以用于实时场景。

研究设计与样本

  • AI工具自动化图像采集、生物测量和报告生成,并通过反馈调查收集超声医师对扫描的感知。

主要发现

  • AI辅助方法每次扫描平均节省7.62分钟(34.7%),差异有统计学意义(p<0.0001)。
  • 两种方法报告时间无差异,生物测量无临床显著差异。
  • AI工具保存满意切面的比例在仅四个核心切面时为93%,全部13个切面时为73%,手动扫描两种情况下均为98%。
  • 调查反馈提示AI工具通过移除干扰性任务帮助超声医师集中精力于图像解读。

临床怎么用

  • AI辅助中孕期筛查超声可缩短扫描时间且不改变生物测量结果,可考虑用于优化工作流程。
  • AI工具通过自动化重复任务可能让超声医师更专注于胎儿畸形的识别。
  • 当前图像平面检测算法在全部13个切面时的满意切面保存率(73%)低于手动扫描(98%),实时应用前需进一步改进。

局限性

  • 图像平面检测算法在全部13个切面时的性能仍需改进以用于实时场景。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Advances in artificial intelligence (AI) have demonstrated potential to improve medical diagnosis. We piloted the end-to-end automation of the mid-trimester screening ultrasound scan using AI-enabled tools. METHODS: A prospective method comparison study was conducted. Participants had both standard and AI-assisted US scans performed. The AI tools automated image acquisition, biometric measurement, and report production. A feedback survey captured the sonographers' perceptions of scanning. RESULTS: Twenty-three subjects were studied. The average time saving per scan was 7.62 min (34.7%) with the AI-assisted method (p < 0.0001). There was no difference in reporting time. There were no clinically significant differences in biometric measurements between the two methods. The AI tools saved a satisfactory view in 93% of the cases (four core views only), and 73% for the full 13 views, compared to 98% for both using the manual scan. Survey responses suggest that the AI tools helped sonographers to concentrate on image interpretation by removing disruptive tasks. CONCLUSION: Separating freehand scanning from image capture and measurement resulted in a faster scan and altered workflow. Removing repetitive tasks may allow more attention to be directed identifying fetal malformation. Further work is required to improve the image plane detection algorithm for use in real time.

来源:Prenat Diagn,查看原文。版权归原作者所有。

引用

  1. Matthew J, Skelton E, Day TG, et al. Exploring a new paradigm for the fetal anomaly ultrasound scan: Artificial intelligence in real time. Prenat Diagn. 2021. PMID: 34648206. doi:10.1002/pd.6059

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。