二维斑点追踪超声评估健康胎儿心肌形变的前瞻性纵向队列研究
该前瞻性纵向队列研究纳入124例无并发症妊娠,从18-21周至分娩每4周进行超声心动图检查,采用二维斑点追踪超声心动图(2D-STE)测量胎儿左右心室整体纵向应变(GLS)及应变率(GLSR),利用贝叶斯混合效应模型建立基于孕龄的参考值。结果显示双心室GLS和GLSR随妊娠进展显著增高(即负值减小),且右心室GLS在各孕周均显著高于左心室。
要点
- 建立了健康胎儿左右心室GLS和GLSR基于孕周的参考值及5%预测限。
- 双心室GLS和GLSR从孕中期至分娩显著增高(负值减小)。
- 右心室GLS在各孕周均显著高于左心室。
核心结论
- 获得了2D-STE测量的胎儿GLS和GLSR参考值,双心室GLS和GLSR从孕中期至分娩显著增高,右心室GLS显著高于左心室。
研究设计与样本
- 前瞻性纵向队列研究,纳入124例无并发症妊娠且胎儿无异常、生长适中的孕妇,从18-21周至分娩每4周进行超声心动图检查。
- 共获得592次左心室和566次右心室GLS及GLSR测量,采用贝叶斯混合效应模型计算基于孕龄的参考值及上下5%预测限。
主要发现
- 双心室GLS和GLSR随妊娠进展显著增高(即负值减小)。
- 右心室GLS在各孕周均显著高于左心室(即负值更小)。
- 左右心室GLS比较采用Wilcoxon符号秩检验。
关键数值与推荐
- 基于贝叶斯混合效应模型建立了双心室GLS和GLSR按孕周的参考值及上下5%预测限。
临床怎么用
- 所获参考值可用于临床评估妊娠并发症(如胎儿生长受限或心脏异常)前的基线参考,但需未来研究验证其临床实用性。
局限性
- 未来需研究评估所获参考值在临床实践(如胎儿生长受限或心脏异常评估)中的帮助。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Two-dimensional speckle-tracking echocardiography (2D-STE) is a promising technique which allows assessment of fetal cardiac function, and can be used in the evaluation of cardiac and non-cardiac diseases in pregnancy. However, reliable fetal reference values for deformation parameters measured using 2D-STE are needed before it can be introduced into clinical practice. This study aimed to obtain reference values for fetal global longitudinal strain (GLS) and GLS rate (GLSR) measured using 2D-STE and compare right and left ventricular values. METHODS: This was a prospective longitudinal cohort study of uncomplicated pregnancies that underwent echocardiography every 4 weeks from inclusion at 18-21 weeks until delivery to obtain four-chamber loops of the fetal heart. Left and right ventricular GLS and GLSR were measured using 2D-STE at each examination. Using Bayesian mixed-effects models, reference values with lower and upper 5% prediction limits were calculated according to gestational age. Right and left ventricular GLS values according to gestational age were compared using the Wilcoxon signed-rank test. RESULTS: A total of 592 left ventricular and 566 right ventricular GLS and GLSR measurements were obtained from 124 women with uncomplicated pregnancy and non-anomalous, appropriately grown fetuses. Reference values were obtained for both fetal ventricles according to gestational week. GLS and GLSR values of both ventricles increased (i.e. became less negative) significantly during pregnancy. Right ventricular GLS values were significantly higher (i.e. less negative) than the respective left ventricular values at every gestational week. CONCLUSIONS: Reference values were obtained for fetal GLS and GLSR measured using 2D-STE. GLS and GLSR values increased significantly for both ventricles from the second trimester until delivery. GLS values were significantly higher for the right ventricle compared with the left ventricle. Future studies are needed to assess whether the obtained reference values are helpful in clinical practice in the assessment of pregnancy complications, such as fetal growth restriction or cardiac anomaly. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
引用
- van Oostrum NHM, de Vet CM, Clur SB, et al. Fetal myocardial deformation measured with two-dimensional speckle-tracking echocardiography: longitudinal prospective cohort study of 124 healthy fetuses. Ultrasound Obstet Gynecol. 2022. PMID: 34558747. doi:10.1002/uog.24781
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。