孕中期早产筛查中宫颈长度测量的预期值偏倚
该研究评估宫颈长度测量是否受观察者偏倚影响,以及掩蔽测量对短宫颈患病率的影响。研究纳入983次宫颈长度测量,掩蔽组短宫颈患病率为5.5%,非掩蔽组为2.7%(P=0.024),掩蔽组宫颈长度分布正态,非掩蔽组偏态。结论认为预期值偏倚存在,掩蔽是改善筛查效果的有效策略。
要点
- 孕中期宫颈长度测量存在预期值偏倚
- 掩蔽测量使短宫颈检出率从2.7%升至5.5%
- 掩蔽测量可改善宫颈长度筛查效果
核心结论
- 宫颈长度测量中存在预期值偏倚,应在孕中期早产筛查中加以考虑。
- 掩蔽已被证明是改善临床实践中宫颈长度筛查效果的有效策略。
研究设计与样本
- 对照组为研究前2018年4月至5月期间由非掩蔽操作者常规测量宫颈长度的女性。
- 共分析983次宫颈长度测量,掩蔽组457次,对照组526次。
主要发现
- 短宫颈患病率在非掩蔽组为2.7%,在掩蔽组为5.5%(P=0.024)。
- 两组间宫颈长度24-25 mm的发生率差异有统计学意义,非掩蔽组低于掩蔽组(0.6% vs 2.4%;P<0.005)。
- 掩蔽组宫颈长度值呈正态分布,而非掩蔽组呈偏态分布。
关键数值与推荐
- 孕中期超声扫描宫颈长度≤25 mm是早产已知危险因素,推荐使用阴道孕酮。
- 研究期间短宫颈女性按常规每日给予200 mg阴道孕酮。
临床怎么用
- 在孕中期早产筛查中测量宫颈长度时,应实施掩蔽以减少预期值偏倚。
- 掩蔽测量可提高短宫颈的检出率,改善筛查性能。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Cervical length (CL) measurement ≤ 25 mm on mid-trimester ultrasound scan is a known risk factor for preterm birth, for which vaginal progesterone is recommended. The aims of this study were to evaluate whether CL measurement is affected by observer bias and to assess the impact on short cervix prevalence of masking CL measurement during routine mid-trimester ultrasound scan. METHODS: This was a flash study designed for a 2-month period (October and November 2018) at Cruces University Hospital (Bizkaia, Spain), in which all CL measurements from routine mid-trimester scans were masked. During the study period, there was no modification of the routine screening method, and women with a short cervix were prescribed 200 mg vaginal progesterone daily as per usual. The control group included women examined in a 2-month period (April and May 2018) prior to the study, in which CL measurements were taken as usual by a non-blinded operator. The primary outcome was the prevalence of short cervix in each group. RESULTS: A total of 983 CL measurements were analyzed, including 457 in the blinded group and 526 in the control group. The prevalence of short cervix was 2.7% in the non-blinded group and 5.5% in the blinded group (P = 0.024). We identified a statistically significant difference in the incidence of CL of 24-25 mm between the two groups, with a lower prevalence in the non-blinded vs blinded group (0.6% vs 2.4%; P < 0.005). Moreover, the distribution of CL values was normal in the blinded group, in contrast to the non-blinded group, which was characterized by skewed distribution of CL values. CONCLUSIONS: Expected-value bias exists and should be taken into account when measuring CL in mid-trimester preterm birth screening. Blinding has demonstrated to be an effective strategy to improve the performance of CL screening in clinical practice. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Aiartzaguena A, Del Campo A, Melchor I, et al. Expected-value bias in mid-trimester preterm birth screening. Ultrasound Obstet Gynecol. 2022. PMID: 34542928. doi:10.1002/uog.24778
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。