产时超声与阴道助产及剖宫产的选择
产时超声较阴道检查能更准确评估胎头位置和站位,国际妇产科超声学会2018年指南推荐在产程停滞或考虑阴道助产时使用。超声可提高胎头位置诊断和器械放置准确性,但未降低发病率;多种超声参数联合模型可能优于单一参数,结合临床与超声参数的算法有助于决策。
要点
- 产时超声客观准确评估胎头位置和站位,优于阴道检查。
- 进展角120°对应胎头站位0,145°对应≥+2且与成功助产相关。
- 会阴-胎头距离≥40mm与困难阴道助产风险增加相关。
核心结论
- 产时超声可提高胎头位置诊断和器械放置准确性,但未降低发病率。
- 多参数超声预测模型优于单一参数模型,结合临床与超声参数的算法有助于助产决策。
研究设计与样本
- 本文为综述,汇总产时超声评估胎头位置和站位的相关研究及国际妇产科超声学会2018年指南推荐。
主要发现
- 超声评估胎头位置通过识别枕骨、眼眶或中线脑回声,较阴道检查更准确。
- 进展角120°对应临床胎头站位0,是成功阴道分娩的重要标志。
- 进展角145°对应临床胎头站位≥+2,与成功阴道助产相关。
- 会阴-胎头距离≥40mm与困难阴道助产风险增加相关。
- 矢状面会阴超声评估的胎头下降「头朝上」方向是成功阴道分娩的有利因素。
关键数值与推荐
- 国际妇产科超声学会2018年指南推荐:怀疑第一或第二产程延迟或停滞,或考虑阴道助产前,应行超声评估。
- 进展角120°对应临床胎头站位0,145°对应≥+2。
- 会阴-胎头距离≥40mm与困难阴道助产风险增加相关。
临床怎么用
- 在产程停滞或考虑阴道助产时,使用产时超声评估胎头位置和站位。
- 结合进展角、会阴-胎头距离等多参数及临床指标综合决策助产方式。
局限性
- 关于不均衡(asynclitism)的超声评估研究有限。
- 超声评估虽提高诊断准确性,但未降低发病率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Inaccurate assessment of the fetal head position and station might increase the risk for difficult or failed assisted vaginal delivery. Compared with digital vaginal examination, an ultrasound examination is objective and more accurate. The International Society of Ultrasound in Obstetrics and Gynecology has issued practical guidelines on intrapartum ultrasound in 2018 and recommended that an ultrasound assessment should be conducted when there is suspected delay or arrest of the first or second stage of labor or before considering assisted vaginal delivery. Fetal head position is assessed transabdominally by identifying the fetal occiput, orbit, or midline cerebral echo. Studies have shown that ultrasound assessment improved the correct diagnosis of fetal head position and accuracy of instrument placement, however, it did not reduce morbidity. Studies on ultrasound assessment of asynclitism are limited but show promising results. Fetal head station is assessed transperineally in the midsagittal or axial plane. Of the various ultrasound parameters, angle of progression and head-perineum distance are the most widely studied and found to be highly correlated with the clinical fetal head station. An angle of progression of 120° correlates with a clinical head station of 0 and is an important landmark for engagement of successful vaginal delivery, whereas an angle of progression of 145° correlates with a clinical head station of ≥+2 and has been associated with successful assisted vaginal delivery. In contrast, a head perineum distance of ≥40 mm has been associated with an increased risk for difficult assisted vaginal delivery. A "head-up" direction of descent assessed transperineally in sagittal plane is also a favorable factor for successful vaginal delivery. Current evidence seems to suggest that a prediction model with >1 sonographic parameter performed better than a model that only used 1 parameter. We suggest that an algorithm model incorporating both clinical and sonographic parameters would be useful in guiding clinicians on their decision for assisted vaginal delivery.
引用
- Chan VYT, Lau WL. Intrapartum ultrasound and the choice between assisted vaginal and cesarean delivery. Am J Obstet Gynecol MFM. 2021. PMID: 34216834. doi:10.1016/j.ajogmf.2021.100439
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。