文献速递母胎医学

经皮胎儿镜脊柱裂修补术中宫内二氧化碳吹入后的胎儿血气分析

Fetal blood gases after in utero carbon dioxide insufflation for percutaneous fetoscopic spina bifida repair.
PubMed 文献 · Am J Obstet Gynecol MFM · 2021-05-28

本研究前瞻性纳入2019年2月至2020年7月接受经皮胎儿镜开放性脊柱裂修补术的患者,对7例在超声引导下于手术结束时行脐静脉穿刺采血,同时采集母体动脉血。结果显示,尽管宫内CO2吹入时间较长,胎儿脐静脉pH和碱剩余未接近提示病理性胎儿酸血症的水平。

要点

  • 经皮胎儿镜脊柱裂修补术中长时间CO2吹入后,胎儿脐静脉pH中位数7.35,未接近病理性酸血症范围。
  • 胎儿脐静脉碱剩余中位数-2.2 mmol/L,亦未提示严重代谢性酸中毒。
  • CO2暴露时间中位数122分钟,最大压力中位数13.5 mm Hg,胎儿血气仍维持可接受范围。

核心结论

  • 尽管宫内CO2吹入时间较长,胎儿脐静脉pH和碱剩余值未接近与潜在病理性胎儿酸血症相关的水平。

研究设计与样本

  • 前瞻性研究,纳入2019年2月至2020年7月接受经皮胎儿镜开放性脊柱裂修补术的患者。
  • 20例手术患者中7例(35%)在超声引导下于手术结束时行脐静脉穿刺采血,同时采集母体动脉血。
  • 手术孕周中位数27.4周(范围24.0-27.9周),手术时间中位数183分钟(范围156-251分钟)。
  • CO2暴露时间中位数122分钟(范围57-146分钟),最大压力中位数13.5 mm Hg(范围12.0-15.0 mm Hg)。

主要发现

  • 胎儿脐静脉血气:pH中位数7.35(范围7.30-7.39),氧分压中位数56.2 mm Hg(范围47.1-99.9 mm Hg)。
  • 胎儿脐静脉二氧化碳分压中位数43.8 mm Hg(范围36.2-53.0 mm Hg),碳酸氢盐中位数23.9 mmol/L(范围20.1-25.6 mmol/L)。
  • 胎儿脐静脉碱剩余中位数-2.2 mmol/L(范围-4.5至-0.4 mmol/L)。
  • 同期母体动脉血气:pH中位数7.37(范围7.28-7.42),氧分压中位数187.5 mm Hg(范围124.4-405.2 mm Hg)。
  • 母体动脉二氧化碳分压中位数36.6 mm Hg(范围30.7-46.0 mm Hg),碳酸氢盐中位数21.3 mmol/L(范围18.0-22.8 mmol/L),碱剩余中位数-3.2 mmol/L(范围-5.9至-1.8 mmol/L)。

临床怎么用

  • 经皮胎儿镜脊柱裂修补术中长时间CO2吹入后,胎儿血气未显示病理性酸血症,支持该技术的安全性评估。

局限性

  • 仅7例(35%)患者获得胎儿血气样本,样本量有限。
  • 仅纳入脐带穿刺条件良好的病例,可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Prenatal repair of open spina bifida via the percutaneous fetoscopic approach does not require maternal laparotomy, hysterotomy, or exteriorization of the uterus. This technique requires intrauterine partial CO2 insufflation. Limited data exist on the physiological effects of CO2 insufflation on human fetuses, with no data on open spina bifida repair performed using the entirely percutaneous fetoscopic surgical technique. OBJECTIVE: Our aim was to examine the effects of intrauterine partial CO2 insufflation on fetal blood gases after percutaneous fetoscopic open spina bifida repair. STUDY DESIGN: This was a prospective study of patients who underwent percutaneous fetoscopic open spina bifida repair from February 2019 to July 2020. Fetal cordocentesis of the umbilical vein was performed in cases with favorable access to the umbilical cord. The umbilical vein cord blood samples were obtained under ultrasound guidance immediately at the conclusion of the open spina bifida repair. Simultaneous maternal arterial blood gas samples were also obtained. The results are reported as median (range). RESULTS: Of the 20 patients who underwent percutaneous fetoscopic open spina bifida repair during the study period, 7 patients (35%) underwent fetal blood sampling. The gestational age at the time of surgery was 27.4 (24.0-27.9) weeks and the operative time was 183 (156-251) minutes. The CO2 exposure time was 122 (57-146) minutes with maximum pressure of 13.5 (12.0-15.0) mm Hg. Fetal umbilical vein results were as follows: pH 7.35 (7.30-7.39), partial pressure of O2 56.2 (47.1-99.9) mm Hg, partial pressure of CO2 43.8 (36.2-53.0) mm Hg, HCO3 23.9 (20.1-25.6) mmol/L, and base excess -2.2 (-4.5 to -0.4) mmol/L. Simultaneous maternal arterial blood gas results were as follows: pH 7.37 (7.28-7.42), partial pressure of O2 187.5 (124.4-405.2) mm Hg, partial pressure of CO2 36.6 (30.7-46.0) mm Hg, HCO3 21.3 (18.0-22.8) mmol/L and base excess -3.2 (-5.9 to -1.8) mmol/L. CONCLUSION: Despite prolonged CO2insufflation of the uterus, fetal umbilical vein pH and base excess values did not approach those associated with potentially pathologic fetal acidemia.

来源:Am J Obstet Gynecol MFM,查看原文。版权归原作者所有。

引用

  1. Sangara RN, Chon AH, Van Speybroeck AL, et al. Fetal blood gases after in utero carbon dioxide insufflation for percutaneous fetoscopic spina bifida repair. Am J Obstet Gynecol MFM. 2021. PMID: 34058420. doi:10.1016/j.ajogmf.2021.100409

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。