动态食管通畅性评估:产前诊断食管闭锁的有效方法
本研究前瞻性纳入130例高危孕妇共132胎,在孕31.4周(中位)行动态食管通畅性评估,以出生后所见为金标准。结果显示食管闭锁检出率100%,无假阳性或假阴性,敏感度、特异度及阳性、阴性预测值均为100%,观察者间与观察者内Kappa系数均为1(P<.0001)。
要点
- 动态食管通畅性评估在高危人群中检出食管闭锁的敏感度和特异度均为100%。
- 吞咽时食管液体传播中断并形成囊袋判为异常,评估中位耗时6.00分钟。
- 观察者间与观察者内一致性Kappa系数均为1(P<.0001)。
核心结论
- 动态食管通畅性评估是确认食管完整及在疑似病例中检出食管闭锁的可行且高效方法。
研究设计与样本
- 前瞻性研究,在单个三级胎儿超声单位进行12个月。
- 研究组纳入因羊水过多、胃小或缺如、VACTERL相关异常、一级亲属食管闭锁或相关基因突变而转诊行针对性扫描的孕妇。
- 共招募130例患者,扫描132个胎儿,扫描时中位孕周31.4周(四分位距29.0-35.3)。
主要发现
- 132个胎儿中123个(93.2%)正常,8个(6%)异常,1个(0.8%)无法确定。
- 排除3例终止妊娠未行尸检者(1例异常、2例正常)及1例无法确定者后行性能分析。
- 食管闭锁检出率100%,无假阳性或假阴性。
- 敏感度、特异度、阳性预测值和阴性预测值均为100%。
- 观察者间和观察者内一致性Kappa系数均为1(P<.0001)。
关键数值与推荐
- 吞咽时食管液体传播不间断判为正常。
- 液体传播中断并形成囊袋判为异常。
- 食管显示不清或未能显示液体传播或囊袋判为无法确定。
临床怎么用
- 对存在羊水过多、胃小或缺如、VACTERL相关异常、家族史或相关基因突变的高危胎儿,可在超声扫查中加行动态食管通畅性评估。
- 评估时观察胎儿吞咽过程中食管液体传播情况,以中断并形成囊袋为异常标准。
- 该方法中位耗时约6分钟,观察者间与观察者内一致性高,适合临床推广。
局限性
- 研究在单个三级胎儿超声单位进行,外推性需进一步验证。
- 3例终止妊娠未行尸检及1例无法确定者被排除在性能分析之外。
- 样本中异常病例仅8例,阳性病例数较少。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Esophageal atresia is a major anomaly with a low prenatal detection rate. We propose a sonographic method termed dynamic esophageal patency assessment. OBJECTIVE: This study aimed to assess the feasibility and performance of the dynamic esophageal patency assessment in a high-risk population. STUDY DESIGN: A prospective study was conducted in a single tertiary fetal ultrasound unit for 12 months. The study group included pregnant women referred for a targeted scan because of one or more of the following: (1) polyhydramnios; (2) small or absent stomach; (3) vertebral, anal atresia, cardiac, tracheoesophageal fistula, renal, and limb abnormalities; (4) first-degree relative with esophageal atresia; and (5) genetic mutation associated with esophageal atresia. In addition to dynamic esophageal patency assessment, a comprehensive anomaly scan was carried out. The fetal esophagus was observed during swallowing. Cases that demonstrated uninterrupted fluid propagation through the esophagus were classified as normal. Cases that demonstrated interrupted fluid propagation, with the formation of a pouch, were classified as abnormal. Cases with unclear visualization of the esophagus or cases that failed to demonstrate either fluid propagation or a pouch were classified as undetermined. Dynamic esophageal patency assessment results were compared with postnatal findings, considered "gold standard." Test performance indices and intra- and interobserver agreements were calculated. RESULTS: For 12 months, 130 patients were recruited, and 132 fetuses were scanned. The median gestational age (interquartile range) at the time of scan was 31.4 weeks (29.0-35.3). Of 132 fetuses enrolled, 123 (93.2%) were normal, 8 (6%) were abnormal, and 1 (0.8%) was undetermined. Excluded from test performance analysis were 3 cases that were terminated without postmortem autopsy (1 was abnormal and 2 were normal), and a fourth case was excluded as it was classified as undetermined. The detection rate of esophageal atresia was 100%, with no false-positive or false-negative case. Sensitivity, specificity, and positive and negative predictive values of the dynamic esophageal patency assessment were 100%. The Kappa coefficient was 1 for both inter- and intraobserver agreements (P<.0001). The median time (interquartile range) required to complete the dynamic esophageal patency assessment was 6.00 minutes (3.00-13.25). CONCLUSION: The dynamic esophageal patency assessment is a feasible and highly effective method of ascertaining an intact esophagus and detecting esophageal atresia in suspected cases.
引用
- Kassif E, Elkan Miller T, Tsur A, et al. Dynamic esophageal patency assessment: an effective method for prenatally diagnosing esophageal atresia. Am J Obstet Gynecol. 2021. PMID: 34146530. doi:10.1016/j.ajog.2021.06.061
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。