胚胎移植过程中胚胎暴露于显著温度下降:一项试点研究
结果显示,从实验室装载导管到手术室置入子宫的转运过程中,导管尖端温度迅速降至环境温度,各诊所条件虽有差异但趋势一致。作者提示这种快速大幅降温可能影响胚胎活力和健康。
要点
- 模拟移植中导管尖端温度在转运途中迅速降至环境温度。
- 各诊所的移植流程、环境温度和装载时导管温度虽有差异,降温趋势一致。
- 作者提示转运中快速大幅降温可能影响胚胎活力,应全程维持温度控制。
核心结论
- 胚胎移植转运过程中导管尖端温度迅速降至环境温度,可能影响胚胎活力与健康。
主要发现
- 所有案例中,装载后导管尖端温度在从实验室工作站转运至手术室途中迅速降至环境温度。
- 各诊所的移植流程、环境温度和装载时导管温度存在差异,但降温趋势一致。
临床怎么用
- 应关注胚胎移植全程的温度控制,确保IVF实验室的严格温控延续至移植操作过程。
局限性
- 原文未报告
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
RESEARCH QUESTION: During the embryo transfer procedure, to what degree of temperature drop are embryos exposed to between loading the transfer catheter and placing it into the uterus? DESIGN: Twenty-nine simulated embryo transfer procedures were carried out across five clinics. A thermocouple probe was used for standardized measurements inside the embryo transfer catheter to investigate the change in temperature that occurred in the time period between loading and placing the catheter in the uterus. RESULTS: In all cases, the temperature at the loaded catheter tip fell rapidly to ambient temperature during transit from the embryo transfer workstation in the laboratory to the procedure room, even though embryo transfer procedures, ambient temperatures and embryo transfer catheter temperatures at loading varied between clinics. CONCLUSIONS: Given the sensitivity of the pre-implantation embryo to its immediate environment, the rapid and profound drop in temperature observed at the catheter tip that houses the embryo during transit from laboratory to the uterus may affect embryo viability and health. This issue should be addressed to ensure that the tight temperature control aimed for by IVF laboratories continues throughout the embryo transfer procedure, and could improve clinical outcomes.
引用
- Macklon N, Delikari O, Lamanna G, et al. Embryos are exposed to a significant drop in temperature during the embryo transfer procedure: a pilot study. Reprod Biomed Online. 2021. PMID: 34172391. doi:10.1016/j.rbmo.2021.05.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。