文献速递妇科

经阴道超声准确评估直肠乙状结肠深部子宫内膜异位症浸润范围

Transvaginal sonography determines accurately extent of infiltration of rectosigmoid deep endometriosis.
PubMed 文献 · Ultrasound Obstet Gynecol · 2021-01-01

这项前瞻性多中心观察性研究纳入166例因直肠乙状结肠深部子宫内膜异位症接受手术的症状性女性,比较术前经阴道超声(TVS)与术后标本测量(PSM)对病灶三个径线的测量一致性。结果显示TVS对病灶长度测量准确,与PSM一致性良好,可用于优化手术方案规划。

要点

  • TVS测量直肠乙状结肠DE病灶长度与术后标本测量一致性良好(ICC 0.82)。
  • TVS对病灶厚度测量具有中等至良好信度(ICC 0.76)。
  • TVS对横径测量信度较差至中等(ICC 0.58),准确性有限。

核心结论

  • 术前TVS能准确测定直肠乙状结肠深部子宫内膜异位症病灶长度,有助于优化手术方案规划。

研究设计与样本

  • 前瞻性观察性多中心研究,2017年4月至2019年12月纳入因直肠乙状结肠DE接受手术的症状性女性,最终分析166例。
  • TVS按IDEA共识标准于术前测量病灶三个径线,与术后标本测量进行比较,采用Bland-Altman图、组内相关系数(ICC)和Pearson相关系数评估一致性。

主要发现

  • TVS与PSM病灶长度平均差异为0.90 mm(95%CI 0.85-0.95),厚度为1.03 mm(95%CI 0.98-1.09),横径为0.84 mm(95%CI 0.79-0.89)。
  • 病灶长度测量ICC为0.82(95%CI 0.75-0.87),Pearson相关系数为0.72(95%CI 0.62-0.80),Bland-Altman分析显示一致性良好。
  • 病灶厚度测量ICC为0.76(95%CI 0.67-0.82),Pearson相关系数为0.61(95%CI 0.51-0.70),信度和相关性中等至良好。
  • 横径测量ICC为0.58(95%CI 0.39-0.71),Pearson相关系数为0.46(95%CI 0.33-0.58),信度和相关性较差至中等。

关键数值与推荐

  • 共166例纳入最终分析,其中123例行节段性切除,46例行碟形切除(3例同时接受两种术式)。
  • TVS测量病灶长度与PSM一致性良好(ICC 0.82),厚度中等至良好(ICC 0.76),横径较差至中等(ICC 0.58)。

临床怎么用

  • 术前TVS可准确评估直肠乙状结肠DE病灶长度,应作为手术规划的重要参考。
  • TVS对病灶厚度测量信度中等,对横径测量信度较低,临床解读横径时需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To investigate the agreement of measurements of the three diameters of rectosigmoid deep endometriosis (DE) lesions between presurgical evaluation using transvaginal sonography (TVS) and postsurgical specimen measurement (PSM). METHODS: This was a prospective observational multicenter study including symptomatic women undergoing surgical treatment for DE involving the rectosigmoid, by either discoid or segmental resection, from April 2017 to December 2019. TVS was performed presurgically to evaluate lesion size (craniocaudal-midsagittal length, anteroposterior thickness and transverse diameter), in accordance with the International Deep Endometriosis Analysis (IDEA) group consensus statement, and was compared with PSM. The agreement of lesion dimensions between the two methods was assessed by Bland-Altman plots and limits of agreement and additionally by the intraclass correlation coefficient (ICC) and Pearson's correlation coefficient. Systematic and proportional bias was assessed using the paired t-test. RESULTS: A total of 207 consecutive women were eligible for inclusion. Forty-one women were excluded, leaving 166 women for final analysis. A total of 123 segmental resections and 46 discoid resections were performed (both procedures were performed in three women). The mean difference between TVS and PSM was 0.90 (95% CI, 0.85-0.95) mm for lesion length measurements, 1.03 (95% CI, 0.98-1.09) mm for lesion thickness measurements and 0.84 (95% CI, 0.79-0.89) mm for transverse diameter measurements. Bland-Altman analysis demonstrated good agreement between the two methods for measurements of lesion length. Furthermore, there was good reliability and correlation between TVS and PSM for lesion length measurements, as demonstrated by an ICC of 0.82 (95% CI, 0.75-0.87) and Pearson's correlation coefficient of 0.72 (95% CI, 0.62-0.80), moderate-to-good reliability and correlation for lesion thickness measurements, with an ICC of 0.76 (95% CI, 0.67-0.82) and Pearson's correlation coefficient of 0.61 (95% CI, 0.51-0.70), and poor-to-moderate reliability and correlation for transverse diameter measurements, with an ICC of 0.58 (95% CI, 0.39-0.71) and Pearson's correlation coefficient of 0.46 (95% CI, 0.33-0.58). CONCLUSION: Preoperative TVS determines accurately rectosigmoid DE lesion length. TVS can thereby contribute to optimal planning of surgical treatment options in women with rectosigmoid DE. © 2021 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Aas-Eng MK, Lieng M, Dauser B, et al. Transvaginal sonography determines accurately extent of infiltration of rectosigmoid deep endometriosis. Ultrasound Obstet Gynecol. 2021. PMID: 34182605. doi:10.1002/uog.23728

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。