孕18至22周宫颈弹性成像预测自发性早产
这项前瞻性队列研究纳入742例单胎孕妇,在孕18至22周行阴道超声宫颈弹性成像(E-Cervix)测量5项参数并建立列线图。
要点
- 孕18至22周宫颈弹性成像参数可重复性良好,但外口硬度重复性差。
- 单变量分析中弹性成像参数均未显著增加自发性早产风险。
- 校正混杂因素后,弹性对比指数与自发性早产风险独立相关。
核心结论
- 宫颈弹性成像参数在孕18至22周测量可靠且稳定。
- 弹性对比指数与自发性早产风险增加相关,可能成为未来研究的有用参数。
研究设计与样本
- 前瞻性队列研究,纳入742例在孕18至22周行阴道超声宫颈长度筛查的单胎孕妇。
- 使用E-Cervix弹性成像应用计算5项定量参数并建立列线图。
- 采用Shrout-Fleiss信度评估观察者内重复性,并构建多变量逻辑回归模型。
主要发现
- 49例(6.6%)发生自发性早产,693例足月产者用于建立列线图。
- 除宫颈外口硬度重复性差(组内相关系数0.441)外,其余参数重复性良好或优秀(组内相关系数0.757-0.887)。
- 单变量分析中,无弹性成像参数与自发性早产风险显著相关。
临床怎么用
- 孕18至22周可尝试使用E-Cervix弹性成像测量宫颈参数,但预测自发性早产的价值尚需进一步研究。
- 弹性对比指数可作为未来早产预测研究的候选参数。
局限性
- 单变量分析中弹性成像参数未显示显著关联,仅多变量模型中弹性对比指数显著。
- 宫颈外口硬度测量重复性差。
- 研究为观察性队列,结论需外部验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Accurate identification of the women who will have spontaneous preterm birth continues to be a great challenge. The use of cervical elastography for prediction of preterm birth is promising, but several limitations exist. Newer cervical elastography technology has been developed that may prove useful in evaluation of risk of preterm birth. OBJECTIVE: This study aimed to develop standard cervical elastography nomograms for singleton pregnancies at 18 to 22 weeks' gestation using the E-Cervix ultrasound application, assess intraobserver reliability of the E-Cervix elastography parameters, and determine whether these cervical elastography measurements can be used in the prediction of spontaneous preterm birth. STUDY DESIGN: This was a prospective cohort study of pregnant women undergoing cervical length screening assessment via transvaginal ultrasound examination at 18 to 22 weeks' gestation. A semiautomatic, cervical elastography application (E-Cervix) was used during the transvaginal examination to calculate 5 quantitative parameters (internal os stiffness, external os stiffness, internal -to -external os stiffness ratio, hardness ratio, and elasticity contrast index) and create a standard nomogram for each one of them. The intraobserver reliability was calculated using Shrout-Fleiss reliability. Cervical elastography parameters were compared between those who delivered preterm (<37 weeks) spontaneously and those who delivered full term. A multivariable logistic regression model was performed to determine the ability of the cervical elastography parameters to predict spontaneous preterm birth. RESULTS: A total of 742 women were included, of which 49 (6.6%) had a spontaneous preterm delivery. A standard nomogram was created for each of the cervical elastography parameters from those who had a full-term birth in the index pregnancy (n=693). Intraobserver reliability was good or excellent (intraclass correlation, 0.757-0.887) for each of the cervical elastography parameters except external os stiffness which was poor (intraclass correlation, 0.441). In univariate analysis, none of the cervical elastography parameters were associated with a statistically significant increased risk of spontaneous preterm birth. In a multivariable model adjusting for history of preterm birth, gravidity, ethnicity, cervical cerclage, and vaginal progesterone use, increasing elasticity contrast index was significantly associated with an increased risk of spontaneous preterm birth (odds ratio, 1.15; 95% confidence interval, 1.02-1.30; P=.02). CONCLUSION: Cervical elastography parameters are reliably measured and are stable across 18 to 22 weeks' gestation. Based on our findings, the elasticity contrast index was associated with an increased risk of spontaneous preterm birth and may be a useful parameter for future research.
引用
- Patberg ET, Wells M, Vahanian SA, et al. Use of cervical elastography at 18 to 22 weeks' gestation in the prediction of spontaneous preterm birth. Am J Obstet Gynecol. 2021. PMID: 34051170. doi:10.1016/j.ajog.2021.05.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。