三维超声心动图与心肌应变成像在妊娠期糖尿病孕妇中的应用
本研究为横断面研究,纳入妊娠26-40周的123例妊娠期糖尿病(GDM)孕妇和246例对照,采用三维超声心动图及斑点追踪应变成像评估双心室功能。结果显示GDM孕妇左、右心室整体纵向应变均低于对照,而射血分数、左心室质量、左房应变及三维功能指标无显著差异,提示应变成像可检测GDM孕妇早期亚临床心肌功能改变。
要点
- GDM孕妇左心室整体纵向应变低于对照(-19.3% vs -20.1%,P=0.002)。
- GDM孕妇右心室整体纵向应变低于对照(-22.2% vs -24.1%,P<0.001)。
- 三维超声心动图所测射血分数、左心室质量等指标组间无显著差异。
核心结论
- 与无并发症妊娠妇女相比,GDM孕妇存在左、右心室心肌形变减低。
- 三维超声心动图容量评估未提供额外的心脏功能信息。
- 应变成像是检测GDM孕妇早期心脏功能变化的敏感超声模态。
研究设计与样本
- 横断面研究,于妊娠26-40周检查。
- 纳入123例GDM孕妇和246例对照,均行超声心动图检查。
- 采用三维超声心动图测量左、右心室及左房容积、射血分数和左心室质量,斑点追踪超声评估左、右心室整体纵向应变及左房应变。
主要发现
- GDM组较对照组年龄更大(35.1 ± 5.2 vs 32.4 ± 5.5岁;P < 0.001)。
- GDM组体质指数更高(30.6(IQR 26.2-35.2) vs 27.5(IQR 24.7-30.7) kg/m2;P < 0.001)。
- GDM组收缩压更高(119.9 ± 11.2 vs 116.4 ± 12.0 mmHg;P = 0.007)。
- GDM组左心室整体纵向应变较低(-19.3%(IQR -21.4 至 -17.6%) vs -20.1%(IQR -22.1 至 -18.7%);P = 0.002)。
- GDM组右心室整体纵向应变较低(-22.2%(IQR -26.1 至 -19.8%) vs -24.1%(IQR -27.0 至 -21.9%);P < 0.001)。
关键数值与推荐
- GDM组所有孕妇血糖控制良好。
- 射血分数、左心室质量、左房应变评估的舒张功能及三维功能指标组间无显著差异。
临床怎么用
- 对GDM孕妇可考虑应用应变成像检测亚临床心肌功能减退。
- 三维超声心动图容量评估在GDM孕妇心脏功能评价中未显示额外价值。
局限性
- 需进一步研究评估有GDM病史女性随年龄增长心脏功能恶化的模式。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Gestational diabetes mellitus (GDM) is associated with premature cardiovascular disease and adverse cardiovascular outcome in the mother. Subclinical cardiac functional changes in the left ventricle have been reported during pregnancy in women with GDM using conventional echocardiography, but results are inconsistent. The aims of the current study were to assess whether GDM is associated with biventricular systolic dysfunction in the mother and whether these cardiac changes can be detected using the novel echocardiographic modalities of strain imaging and three-dimensional (3D) echocardiography. METHODS: This was a cross-sectional study in women with GDM and controls examined at 26-40 weeks of gestation. All women underwent echocardiography, and 3D volumes of the left and right ventricles and left atrium were collected. Ejection fraction and left ventricular mass were measured using 3D echocardiography. Left ventricular mass was indexed to body surface area. Speckle-tracking echocardiography was used to assess global longitudinal strain of the left and right ventricles and strain of the left atrium. RESULTS: The study population included 123 women with GDM and 246 controls. Women with GDM, compared to controls, were older (35.1 ± 5.2 vs 32.4 ± 5.5 years; P < 0.001), had higher body mass index (30.6 (interquartile range (IQR), 26.2-35.2) vs 27.5 (IQR, 24.7-30.7) kg/m2 ; P < 0.001) and had higher systolic blood pressure (119.9 ± 11.2 vs 116.4 ± 12.0 mmHg; P = 0.007). In all women with GDM, there was good glycemic control. In women with GDM, compared to controls, there was lower global longitudinal strain of the left ventricle (-19.3% (IQR, -21.4 to -17.6%) vs -20.1% (IQR, -22.1 to -18.7%); P = 0.002) and right ventricle (-22.2% (IQR, -26.1 to -19.8%) vs -24.1% (IQR, -27.0 to -21.9%); P < 0.001). There was no significant difference between the groups in ejection fraction, left ventricular mass, diastolic function assessed by left atrial strain, or 3D functional indices. CONCLUSIONS: Women with GDM, compared to women with uncomplicated pregnancy, have lower left and right ventricular myocardial deformation. Volumetric assessment using 3D echocardiography does not provide additional information about maternal cardiac function. Strain imaging is a sensitive echocardiographic modality to detect early cardiac functional changes in women with GDM. Further studies are needed to assess the pattern of deterioration of cardiac function with advancing age in women with a history of GDM. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Company Calabuig AM, Nunez E, Sánchez A, et al. Three-dimensional echocardiography and cardiac strain imaging in women with gestational diabetes mellitus. Ultrasound Obstet Gynecol. 2021. PMID: 33949740. doi:10.1002/uog.23666
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。