臀位进展角:评估胎儿臀位下降的新经会阴超声参数
本研究纳入44例34-41周臀位单胎孕妇,经会阴超声测量臀位进展角(BPA),评估其可行性与可重复性。结果显示BPA测量成功率高,观察者内和观察者间ICC分别为0.88和0.83,一致性极好,且不受母亲BMI、年龄、孕周和产次影响。
要点
- 经会阴超声测量BPA在臀位孕妇中可行且可重复性高。
- 观察者内ICC为0.88,观察者间ICC为0.83,一致性极好。
- BPA测量不受母亲BMI、年龄、孕周和产次显著影响。
核心结论
- BPA是评估胎儿臀位在产道下降的一种可行且高度可重复的新测量方法。
研究设计与样本
- 前瞻性队列研究,纳入44例34-41周臀位单胎孕妇,每例由一名操作者测量两次、另一名操作者测量一次BPA。
主要发现
- BPA在所有图像上均由两名操作者成功测量。
- 观察者内ICC为0.88(95% CI,0.80-0.93),观察者间ICC为0.83(95% CI,0.71-0.90)。
- 观察者内平均差异为0.4°(95% CI,-1.4至2.2°),观察者间平均差异为-0.4°(95% CI,-2.6至1.8°)。
- 观察者内一致性上限为12.0°(95% CI,8.9-15.1°),下限为-11.2°(95% CI,-14.3至-8.1°)。
- 观察者间一致性上限为13.6°(95% CI,9.9-17.3°),下限为-14.4°(95% CI,-18.2至-10.7°)。
临床怎么用
- BPA可作为经会阴超声评估臀位胎儿下降的客观指标,但预测外倒转成功或臀位阴道分娩的效用尚需未来研究验证。
局限性
- 样本量较小(44例),且未评估BPA对临床结局(如外倒转成功、臀位阴道分娩)的预测价值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To assess the feasibility and reliability of transperineal ultrasound in the assessment of fetal breech descent in the birth canal, by measuring the breech progression angle (BPA). METHODS: Women with a singleton pregnancy with the fetus in breech presentation between 34 and 41 weeks' gestation were recruited. Transperineal ultrasound images were acquired in the midsagittal view for each woman, twice by one operator and once by another. Each operator measured the BPA after anonymization of the transperineal ultrasound images. BPA was defined as the angle between a line running along the long axis of the pubic symphysis and another line extending from the most inferior portion of the pubic symphysis tangentially to the lowest recognizable fetal part in the maternal pelvis. Each operator was blinded to all other measurements performed for each woman. Intra- and interobserver reproducibility of BPA measurement was evaluated using the intraclass correlation coefficient (ICC). To investigate the presence of any bias, intra- and interobserver agreement was also analyzed using Bland-Altman analysis. Student's t-test and Levene's W0 test were used to investigate whether a number of different clinical factors had an effect on systematic differences and homogeneity, respectively, between BPA measurements. RESULTS: Overall, 44 women were included in the analysis. BPA was measured successfully by both operators on all images. Both intra- and interobserver agreement analyses showed excellent reproducibility in BPA measurement, with ICCs of 0.88 (95% CI, 0.80-0.93) and 0.83 (95% CI, 0.71-0.90), respectively. The mean difference between measurements was 0.4° (95% CI, -1.4 to 2.2°) for intraobserver repeatability and -0.4° (95% CI, -2.6 to 1.8°) for interobserver repeatability. The upper limits of agreement were 12.0° (95% CI, 8.9-15.1°) and 13.6° (95% CI, 9.9-17.3°) for intra- and interobserver repeatability, respectively. The lower limits of agreement were -11.2° (95% CI, -14.3 to -8.1°) and -14.4° (95% CI, -18.2 to -10.7°) for intra- and interobserver repeatability, respectively. No systematic difference between BPA measurements was found on either intra- or interobserver agreement analysis. None of the clinical factors examined (maternal body mass index, maternal age, gestational age at the ultrasound scan and parity) showed a statistically significant effect on intra- or interobserver reliability. CONCLUSIONS: BPA represents a new feasible and highly reproducible measurement for the evaluation of fetal breech descent in the birth canal. Future studies assessing its usefulness in the prediction of successful external cephalic version and breech vaginal delivery are needed. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Youssef A, Brunelli E, Fiorentini M, et al. Breech progression angle: new feasible and reliable transperineal ultrasound parameter for assessment of fetal breech descent in birth canal. Ultrasound Obstet Gynecol. 2021. PMID: 33847431. doi:10.1002/uog.23649
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。