文献速递妇科

新型荧光输尿管导管在全腹腔镜子宫切除术中定位输尿管的初步应用

Use of a Novel Fluorescent Catheter to Locate the Ureters during Total Laparoscopic Hysterectomy.
PubMed 文献 · J Minim Invasive Gynecol · 2021-04-19

本文报道3例40至50岁因子宫肌瘤行全腹腔镜子宫切除及双侧输卵管切除术的患者,术中置入含荧光染料的近红外线导管(NIRC)辅助输尿管定位。导管置入耗时4分9秒至10分57秒,在近红外光下显示绿色,便于实时确认输尿管位置;术后随访6个月未见尿路感染或损伤。作者认为预防性使用该导管可能改善高危患者输尿管可视化。

要点

  • NIRC在近红外光下呈绿色,可实时确认输尿管位置。
  • 3例导管置入耗时4分9秒至10分57秒,术后6个月无尿路感染或损伤。
  • 高危患者(严重粘连、子宫增大致输尿管偏移)或腹腔镜经验少者可考虑预防性使用。

核心结论

  • 预防性使用荧光输尿管导管可能改善高危患者全腹腔镜子宫切除术中输尿管可视化并提高手术安全性。

研究设计与样本

  • 本文为单中心病例报告,纳入3例40至50岁(平均46.3±4.5岁)因子宫肌瘤行全腹腔镜子宫切除及双侧输卵管切除术的患者。

主要发现

  • 导管置入耗时4分9秒至10分57秒。
  • 术中在输尿管附近完成子宫动脉识别与结扎、主韧带分离、阴道壁切开及阴道残端缝合等操作。
  • 导管在近红外光下呈绿色,便于实时确认输尿管位置。
  • 术后随访6个月未见尿路感染或损伤。

临床怎么用

  • 对预计因严重粘连或子宫增大导致输尿管偏移的高危患者,可考虑预防性置入荧光输尿管导管辅助定位。
  • 腹腔镜手术经验较少的术者也可考虑使用该导管提高输尿管可视化。

局限性

  • 样本量仅3例,为初步经验报道,证据级别有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Ureteral injury can occur during total laparoscopic hysterectomy. This report documents our experience in using the near-infrared ray catheter (NIRC), a newly developed fluorescent ureteral catheter made of material that contains a fluorescent dye to improve visualization of the ureters. We have used the device in 3 patients between 40 and 50 years of age (mean, 46.3 ± 4.5 years) undergoing total laparoscopic hysterectomy and bilateral salpingectomy for uterine myomas. The time of catheter insertion ranged from 4 minutes and 9 seconds to 10 minutes and 57 seconds. A number of intraoperative procedures were performed near the ureters, namely, identification and ligation of the uterine arteries, dissection of the cardinal ligament, incision of the vaginal canal, and suturing of the vaginal stump. The abovementioned fluorescent ureteral catheter appears green on a monitor when illuminated by near-infrared light, and this facilitated real-time confirmation of the ureter positions, increasing surgical safety. The patients were followed up for 6 months postoperatively, and no urinary tract infection or injury was found. Prophylactic use of the fluorescent ureteral catheter may improve visualization of the ureters in patients considered to be at high risk of ureteral injury, such as those expected to exhibit ureteral deviation due to severe adhesions or an enlarged uterus and when the surgeon has little experience in laparoscopic surgery.

来源:J Minim Invasive Gynecol,查看原文。版权归原作者所有。

引用

  1. Fujita H, Kikuchi I, Nakagawa R, et al. Use of a Novel Fluorescent Catheter to Locate the Ureters during Total Laparoscopic Hysterectomy. J Minim Invasive Gynecol. 2021. PMID: 33887490. doi:10.1016/j.jmig.2021.04.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。