文献速递产科母胎医学

3T死后磁共振成像对胎儿先天性心脏病的诊断质量

Diagnostic quality of 3Tesla postmortem magnetic resonance imaging in fetuses with and without congenital heart disease.
PubMed 文献 · Am J Obstet Gynecol · 2021-03-01

该研究纳入222例12-41周胎儿,评估3T死后磁共振成像(MRI)心脏评估的可行性和诊断准确性。87.8%的检查评为可诊断,与尸检相比检测先天性心脏缺陷的敏感度87.8%、特异度97.9%、一致率95.3%。在病理资源有限或家属拒绝尸检时,3T死后MRI可作为指导靶向尸检或虚拟尸检的合适影像方法。

要点

  • 3T死后MRI在87.8%的胎儿中可诊断心脏,与尸检一致率95.3%。
  • 诊断准确性在<20周、低出生体重、自然死亡、死亡至MRI间隔长及高度浸软时降低。
  • 3T死后MRI可指导靶向尸检或提供虚拟尸检。

核心结论

  • 3T死后MRI对胎儿心脏评估在多数12周以上胎儿中可行,诊断图像中检测先天性心脏病的敏感度和特异度高。

研究设计与样本

  • 连续纳入222例12-41周妊娠胎儿,在自然死亡或终止妊娠后行3T死后MRI和常规尸检。
  • 由2名独立评估者评定MRI心脏评估可诊断性,视觉分级分析各心脏结构图像质量。
  • 2名放射科医生评估先天性心脏缺陷存在与否,并与尸检结果比较。

主要发现

  • 87.8%的3T死后MRI检查评为可诊断胎儿心脏。
  • 各心脏结构可诊断率范围85.1%(房室瓣)至94.6%(心包),评估者间一致性0.82(0.78-0.86)。
  • 主动脉弓和体静脉在12+5周起可诊断比例分别为90.1%和92.3%。
  • 尸检显示55例(24.8%)有至少1个心脏异常,164例(73.9%)心脏正常,3例(1.4%)尸检心脏无法诊断。
  • 在可诊断检查中,3T死后MRI检测先天性心脏缺陷的敏感度87.8%、特异度97.9%、与尸检一致率95.3%。

关键数值与推荐

  • 3T死后MRI准确性在<20周较≥20周低(P<.001)。
  • 准确性在出生体重≤100g较>100g低(P<.001)。
  • 准确性在自然胎儿死亡后较其他死亡方式低(P=.012)。
  • 准确性随死亡至3T死后MRI间隔增加而降低(P<.001)。
  • 准确性在浸软评分3较0-2低(P=.004)。

临床怎么用

  • 3T死后MRI可作为指导靶向常规尸检的影像方法,适用于病理资源有限时。
  • 在父母拒绝完整尸检时,3T死后MRI可提供虚拟尸检。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Postmortem confirmation of prenatally diagnosed congenital heart disease after termination of pregnancy and evaluation of potential cardiac defects after spontaneous fetal or neonatal death are essential. Conventional autopsy rates are decreasing, and 1.5Tesla magnetic resonance imaging has demonstrated limited diagnostic accuracy for postmortem cardiovascular assessment. OBJECTIVE: This study aimed to evaluate the feasibility and image quality of cardiac 3Tesla postmortem magnetic resonance imaging and to assess its diagnostic accuracy in detecting fetal heart defects compared with conventional autopsy. Secondarily, the study aimed to explore whether clinical factors affect the quality of 3Tesla postmortem magnetic resonance imaging. STUDY DESIGN: A total of 222 consecutive fetuses between 12 and 41 weeks' gestation, who underwent 3Tesla postmortem magnetic resonance imaging and conventional autopsy after spontaneous death or termination of pregnancy for fetal malformations, were included. First, 3Tesla postmortem magnetic resonance imaging of each fetus was rated as diagnostic or nondiagnostic for fetal cardiac assessment by 2 independent raters. The image quality of individual cardiac structures was then further evaluated by visual grading analysis. Finally, the presence or absence of a congenital heart defect was assessed by 2 radiologists and compared with autopsy results. RESULTS: Overall, 87.8% of 3Tesla postmortem magnetic resonance imaging examinations were rated as diagnostic for the fetal heart. Diagnostic imaging rates of individual cardiac structures at 3Tesla postmortem magnetic resonance imaging ranged from 85.1% (atrioventricular valves) to 94.6% (pericardium), with an interrater agreement of 0.82 (0.78-0.86). Diagnostic imaging of the fetal aortic arch and the systemic veins at 3Tesla postmortem magnetic resonance imaging was possible from 12+5 weeks' gestation onward in 90.1% and 92.3% of cases, respectively. A total of 55 fetuses (24.8%) had at least 1 cardiac anomaly according to autopsy, 164 (73.9%) had a normal heart, and in 3 fetuses (1.4%), autopsy was nondiagnostic for the heart. Considering all examinations rated as diagnostic, 3Tesla postmortem magnetic resonance imaging provided high diagnostic accuracy for the detection of fetal congenital heart defects with a sensitivity of 87.8%, a specificity of 97.9%, and concordance with autopsy of 95.3%. 3Tesla postmortem magnetic resonance imaging was less accurate in young fetuses (<20 weeks compared with ≥20 weeks; P<.001), in fetuses with low birthweight (≤100 g compared with >100 g; P<.001), in cases after spontaneous fetal death (compared with other modes of death; P=.012), in cases with increasing latency between death and 3Tesla postmortem magnetic resonance imaging (P<.001), and in cases in which there was a high degree of maceration (maceration score of 3 compared with a score from 0 to 2; P=.004). CONCLUSION: Diagnostic 3Tesla postmortem magnetic resonance imaging assessment of the fetal heart is feasible in most fetuses from 12 weeks' gestation onward. In diagnostic images, sensitivity and, particularly, specificity in the detection of congenital heart disease are high compared with conventional autopsy. Owing to its high diagnostic accuracy, we suggest that 3Tesla postmortem magnetic resonance imaging may serve as a suitable imaging modality with which to direct a targeted conventional autopsy when pathology resources are limited or to provide a virtual autopsy when full autopsy is declined by the parents.

来源:Am J Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Ulm B, Dovjak GO, Scharrer A, et al. Diagnostic quality of 3Tesla postmortem magnetic resonance imaging in fetuses with and without congenital heart disease. Am J Obstet Gynecol. 2021. PMID: 33662361. doi:10.1016/j.ajog.2021.02.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。