文献速递产科母胎医学

左侧膈疝无肝疝出者胃位置对新生儿结局的影响

Decreased neonatal morbidity in 'stomach-down' left congenital diaphragmatic hernia: implications of prenatal ultrasound diagnosis for counseling and postnatal management.
PubMed 文献 · Ultrasound Obstet Gynecol · 2021-01-01

本研究回顾性分析2008年1月至2017年3月在本机构产前超声诊断并在产后修补的左侧先天性膈疝(CDH)无肝疝出病例,比较胃位于腹腔(stomach-down)与胃疝入胸腔(stomach-up)的新生儿结局。结果显示两组产前超声o/e-LHR和MRI o/e-TLV无显著差异,但stomach-down组插管时间、ECMO时间、30天需氧率和初始肺动脉高压率均更低,无新生儿死亡。

要点

  • 无肝疝出的左侧CDH中,37.8%为stomach-down,其中35.7%被误诊为肺部病变。
  • stomach-down组插管时间、ECMO时间和30天需氧率均低于stomach-up组。
  • 两组o/e-LHR和o/e-TLV无显著差异,但stomach-down组新生儿发病率更低。

核心结论

  • 在无肝疝出的左侧CDH婴儿中,尽管o/e-LHR和o/e-TLV相似,stomach-down CDH的新生儿发病率低于胃疝入胸腔者。

主要发现

  • stomach-down组与stomach-up组的中位o/e-LHR分别为41.5%和38.4%(P=0.41),中位MRI o/e-TLV分别为49.5%和44.0%(P=0.22)。
  • stomach-down组与stomach-up组的中位插管时间分别为9.5天和18天(P<0.01),中位ECMO时间分别为223.5小时和495小时(P<0.05)。
  • stomach-down组与stomach-up组的30天需氧率分别为3/26(11.5%)和20/42(47.6%)(P<0.01),初始产后超声心动图肺动脉高压率分别为9/26(34.6%)和28/42(66.7%)(P=0.01)。
  • stomach-down组无新生儿死亡,stomach-up组有1例新生儿死亡。
  • 28例stomach-down CDH中,10例(35.7%)被转诊怀疑肺部病变。

临床怎么用

  • 产前超声准确描述CDH中胃的位置有助于产前咨询和产后管理。
  • stomach-down左侧CDH可能被误诊为肺部肿块,需注意鉴别。

局限性

  • 回顾性研究,样本量有限,部分病例缺乏产后结局数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the influence of stomach position on postnatal outcome in cases of left congenital diaphragmatic hernia (CDH) without liver herniation, diagnosed and characterized on prenatal ultrasound (US), by comparing those with ('stomach-up' CDH) to those without ('stomach-down' CDH) intrathoracic stomach herniation. METHODS: Infants with left CDH who underwent prenatal US and postnatal repair at our institution between January 2008 and March 2017 were eligible for inclusion in this retrospective study. Detailed prenatal US examinations, fetal magnetic resonance imaging (MRI) studies, operative reports and medical records of infants enrolled in the pulmonary hypoplasia program at our institution were reviewed. Cases with liver herniation and those with an additional anomaly were excluded. Cases in which bowel loops were identified within the fetal chest on US while the stomach was intra-abdominal were categorized as having stomach-down CDH. Cases in which bowel loops and the stomach were visualized within the fetal chest on US were categorized as having stomach-up CDH. Prenatal imaging findings and postnatal outcomes were compared between the two groups. RESULTS: In total, 152 patients with left CDH were initially eligible for inclusion. Seventy-eight patients had surgically confirmed liver herniation and were excluded. Of the 74 included CDH cases without liver herniation, 28 (37.8%) had stomach-down CDH and 46 (62.2%) had stomach-up CDH. Of the 28 stomach-down CDH cases, 10 (35.7%) were referred for a suspected lung lesion. Sixty-eight (91.9%) cases had postnatal outcome data available for analysis. There was no significant difference in median observed-to-expected (o/e) lung-area-to-head-circumference ratio (LHR) between cases with stomach-down CDH and those with stomach-up CDH (41.5% vs 38.4%; P = 0.41). Furthermore, there was no difference in median MRI o/e total lung volume (TLV) between the two groups (49.5% vs 44.0%; P = 0.22). Compared with stomach-up CDH patients, stomach-down CDH patients demonstrated lower median duration of intubation (18 days vs 9.5 days; P < 0.01), median duration of extracorporeal membrane oxygenation (495 h vs 223.5 h; P < 0.05), rate of supplemental oxygen requirement at 30 days of age (20/42 (47.6%) vs 3/26 (11.5%); P < 0.01) and rate of pulmonary hypertension at initial postnatal echocardiography (28/42 (66.7%) vs 9/26 (34.6%); P = 0.01). No neonatal death occurred in stomach-down CDH patients and one neonatal death was seen in a patient with intrathoracic stomach herniation. CONCLUSIONS: In infants with left CDH without liver herniation, despite similar o/e-LHR and o/e-TLV, those with stomach-down CDH have decreased neonatal morbidity compared to those with stomach herniation. Progressive or variable physiological distension of the stomach over the course of gestation may explain these findings. Stomach-down left CDH is mistaken for a lung mass in a substantial proportion of cases. Accurate prenatal US characterization of CDH is crucial for appropriate prenatal counseling and patient management. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Didier RA, Oliver ER, Rungsiprakarn P, et al. Decreased neonatal morbidity in 'stomach-down' left congenital diaphragmatic hernia: implications of prenatal ultrasound diagnosis for counseling and postnatal management. Ultrasound Obstet Gynecol. 2021. PMID: 33724570. doi:10.1002/uog.23630

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。