PubMed 文献 · Am J Obstet Gynecol · 2021-03-23

本研究为随机对照试验,纳入177例足月、单胎头位、Bishop评分<6且宫颈扩张<2cm的引产孕妇,比较单球囊导管计划6小时与12小时取出联合催产素的引产时间。结果显示6小时组从置入至分娩时间显著缩短(19.2 vs 24.3小时,P=.04),24小时内分娩比例更高(67.4% vs 47.4%,P<.01),且不增加剖宫产率。

要点

  • 单球囊导管联合催产素引产,计划6小时取出较12小时取出可缩短分娩时间。
  • 6小时组24小时内分娩比例显著高于12小时组(67.4% vs 47.4%)。
  • 两组剖宫产率及母儿次要结局无差异,可考虑在临床方案中缩短球囊放置时间。

核心结论

  • 单球囊导管联合催产素引产时,计划6小时取出较12小时取出可缩短从置入至分娩的时间,且不增加剖宫产率。

研究设计与样本

  • 随机对照试验,纳入足月、单胎头位、年龄18-50岁、Bishop评分<6且宫颈扩张<2cm的初产妇和经产妇,随机分为6小时组(89例)和12小时组(88例),最终分析177例。

主要发现

  • 6小时组从导管置入至分娩时间显著短于12小时组(19.2 vs 24.3小时;P=.04)。
  • 6小时组24小时内分娩比例显著高于12小时组(67.4% vs 47.4%;P<.01)。
  • 两组在取出导管时Bishop评分及母儿次要结局方面无差异。
  • 在剔除剖宫产的Cox比例风险模型中,6小时组置入至分娩时间仍显著更短(风险比0.67;P=.02)。

临床怎么用

  • 对于使用单球囊导管联合催产素引产的足月单胎头位孕妇,可考虑将计划取出球囊的时间定为6小时而非12小时,以缩短分娩时间且不增加剖宫产。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Induction of labor is common in the United States. Multiple previous studies have tried to outline a faster time to delivery to improve maternal and fetal outcomes. OBJECTIVE: This study aimed to evaluate whether women who undergo induction of labor with a single-balloon catheter and oxytocin have a shorter time to delivery with planned removal of the catheter at 6 vs 12 hours. STUDY DESIGN: In this randomized controlled trial, induction of labor was performed using a combination of single-balloon catheter and oxytocin. Term women, both nulliparous and multiparous, aged 18 to 50 years old with cephalic singletons were included if they were undergoing induction of labor with a Bishop score of <6 and cervical dilation of <2 cm. Women were randomized to planned removal of the single-balloon catheter at 6 hours vs 12 hours. The primary outcome was time from catheter insertion to delivery. We were powered to show a 4-hour time difference with a sample size of 89 women per group (n=178). Planned sensitivity analyses were performed to account for cesarean delivery in labor. RESULTS: From February 2019 to June 2020, 237 women were screened, 178 women were randomized, and 177 women were included in the final analysis (89 women in the 6-hour group and 88 women in the 12-hour group). Insertion to delivery time was significantly shorter in the 6-hour group (19.2 vs 24.3 hours; P=.04), and the proportion of women delivered by 24 hours was significantly greater in the 6-hour group (67.4% vs 47.4%; P<.01). There was no difference in the Bishop score at removal of the catheter or secondary maternal or neonatal outcomes. In a Cox proportional-hazards model censoring for cesarean delivery, the 6-hour group had a significantly shorter insertion to delivery time (hazard ratio, 0.67; P=.02). CONCLUSION: Induction of labor with a single-balloon catheter and oxytocin with planned removal of the catheter at 6 hours rather than 12 hours results in a shorter time from insertion to delivery without increasing the rate of cesarean delivery. Decreasing the length of time a single-balloon catheter is in place should be considered in clinical protocols.

来源:Am J Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Lassey SC, Haber HR, Kanbergs A, et al. Six versus twelve hours of single-balloon catheter placement with oxytocin administration for labor induction: a randomized controlled trial. Am J Obstet Gynecol. 2021. PMID: 33771496. doi:10.1016/j.ajog.2021.03.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。