该开放标签随机对照试验在肯尼亚一家医院纳入508例低危孕妇,比较孕36+0至37+6周常规超声与基于宫高系列测量的选择性超声对小于胎龄儿(SGA)的检出效果。结果显示常规超声对SGA和严重SGA的检出率均显著高于标准 care,且特异性高,ROC曲线下面积更大。
要点
- 低危孕妇孕36+0至37+6周常规超声对SGA检出率52.8%,显著高于标准 care 的7.7%。
- 常规超声对严重SGA检出率66.7%,显著高于选择性超声的8.3%。
- 常规超声预测SGA的ROC曲线下面积0.92,优于选择性超声的0.68。
核心结论
- 在低危妊娠中,孕36+0至37+6周常规超声检测真性SGA优于基于宫高系列测量的选择性超声,且特异性高。
研究设计与样本
- 开放标签随机对照试验,2018年5月至2020年2月在肯尼亚一家医院开展,508例低危孕妇按1:1随机分组,干预组253例,对照组255例。
主要发现
- 干预组36例、对照组26例新生儿出生体重低于第10百分位。
- 常规超声对SGA检出率为52.8%(19/36),标准 care 为7.7%(2/26),P<0.001。
- 常规超声对SGA特异性为95.5%(191/200),标准 care 为97.9%(191/195),P=0.08。
- 常规超声对严重SGA检出率为66.7%(12/18),选择性超声为8.3%(1/12),P<0.001。
- 常规超声预测SGA的ROC曲线下面积为0.92(95%CI 0.87-0.96),选择性超声为0.68(95%CI 0.58-0.77),P<0.001。
关键数值与推荐
- 超声评估胎儿生长采用腹围(AC)测量,AC低于第10百分位诊断SGA胎儿。
- 主要预设结局为新生儿SGA(出生体重低于第10百分位)和严重新生儿SGA(出生体重低于第3百分位)。
临床怎么用
- 对低危孕妇可在孕36+0至37+6周安排常规超声评估胎儿生长,以提高SGA检出率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To compare the proportion of small-for-gestational-age (SGA) infants detected by routine third-trimester ultrasound vs those detected by selective ultrasound based on serial symphysis-fundus height (SFH) measurements (standard care) in low-risk pregnancy. METHODS: This was an open-label randomized controlled trial conducted at a hospital in Kenya between May 2018 and February 2020. Low-risk pregnant women were randomly allocated (ratio of 1:1) to routine ultrasound for fetal growth assessment between 36 + 0 and 37 + 6 weeks' gestation (intervention group) or to standard care, which involved a selective growth scan on clinical suspicion of fetal growth abnormality based on serial SFH measurements (control group). During ultrasound examination, fetal growth was assessed by measurement of the abdominal circumference (AC), and AC < 10th centile was used to diagnose a SGA fetus. The main prespecified outcomes were the detection of neonatal SGA, defined as birth weight < 10th centile, and of severe neonatal SGA, defined as birth weight < 3rd centile. The predictive performance of routine third-trimester ultrasound and selective ultrasound based on serial SFH measurements was determined using receiver-operating-characteristics (ROC)-curve analysis. RESULTS: Of 566 women assessed for eligibility, 508 (89.8%) were randomized, of whom 253 were allocated to the intervention group and 255 to the control group. Thirty-six babies in the intervention group and 26 in the control group had a birth weight < 10th centile. The detection rate of SGA infants by routine third-trimester ultrasound vs that by standard care was 52.8% (19/36) vs 7.7% (2/26) (P < 0.001) and the specificity was 95.5% (191/200) and 97.9% (191/195), respectively (P = 0.08). The detection rate of severe SGA was 66.7% (12/18) by routine ultrasound vs 8.3% (1/12) by selective ultrasound based on SFH measurements (P < 0.001), with specificities of 91.7% (200/218) and 98.1% (205/209), respectively (P = 0.006). The area under the ROC curve of routine third-trimester ultrasound in prediction of SGA was significantly greater than that of selective ultrasound based on SFH measurements (0.92 (95% CI, 0.87-0.96) vs 0.68 (95% CI, 0.58-0.77); P < 0.001). CONCLUSIONS: In low-risk pregnancy, routine ultrasound performed between 36 + 0 and 37 + 6 weeks is superior to selective ultrasound based on serial SFH measurements for the detection of true SGA, with high specificity. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.