高危妊娠产前胎心监护:计算机分析与标准方法随机对照试验
单中心、非盲、平行组随机临床试验纳入24 0/7至37 6/7周住院高危妊娠单胎孕妇28例,1:1分配至标准胎心监护组或计算机分析胎心监护组。主要结局剖宫产率两组均为64.3%(9/14),相对风险1.00(95%CI 0.21-4.69)。计算机分析未显著增加剖宫产,早产、分娩孕周、Apgar评分及出生体重组间无显著差异。
要点
- 高危妊娠产前监护中,计算机分析胎心监护未显著增加剖宫产率。
- 两组剖宫产率均为64.3%,RR 1.00(95%CI 0.21-4.69)。
- 单中心小样本结果需多中心研究证实。
核心结论
- 在高危妊娠孕妇中,产前使用计算机分析胎心监护相比标准胎心监护未导致剖宫产发生率显著增加。
- 该单中心随机试验结果需多中心研究进一步确认。
研究设计与样本
- 平行组非盲随机临床试验,纳入24 0/7至37 6/7周住院监护的高危妊娠单胎孕妇。
- 按1:1随机分配至标准胎心监护组或计算机分析胎心监护组,共纳入28例,每组14例。
- 随机后无排除、无失访。
主要发现
- 计算机分析组剖宫产9例(64.3%),对照组剖宫产9例(64.3%)。
- 相对风险1.00(95%CI 0.21-4.69)。
- 早产、分娩孕周、Apgar评分及出生体重组间无显著差异。
临床怎么用
- 对于无宫内生长受限的高危妊娠孕妇,产前胎心监护加用计算机分析未见剖宫产增加,可作为监护方式选择时的参考。
- 鉴于样本量小且为单中心,临床应用应结合其他证据与个体情况谨慎判断。
局限性
- 单中心设计,样本量仅28例,统计效能有限。
- 非盲法试验,可能存在偏倚。
- 结果需多中心研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Cardiotocography or nonstress test is a technical means of recording the fetal heartbeat and uterine contractions for antenatal monitoring. OBJECTIVE: This study aimed to evaluate whether antepartum cardiotocography with computer analysis (computerized cardiotocography) increases the incidence of cesarean delivery in women with high-risk pregnancies but without intrauterine growth restriction. STUDY DESIGN: This was a parallel group nonblinded randomized clinical trial of singletons with high-risk pregnancies admitted for inpatient monitoring between 24 0/7 and 37 6/7 weeks' gestation. Eligible participants were randomly allocated in a 1:1 ratio to antenatal monitoring with either standard cardiotocography or computerized cardiotocography. Women randomized to the computerized cardiotocography arm received cardiotocographic monitoring with computerized analysis in a central monitoring station. The primary outcome was the incidence of cesarean delivery. RESULTS: Overall, 28 women were enrolled in this trial. In addition, 14 women were randomized to the computerized cardiotocography group and 14 women to the control group. No woman was excluded after randomization or lost to follow-up. Cesarean delivery occurred in 9 women (64.3%) in the computerized cardiotocography group and 9 women (64.3%) in the control group (relative risk, 1.00; 95% confidence interval, 0.21-4.69).There was no significant between-group difference in preterm birth, gestational age at delivery, Apgar score, and birthweight. CONCLUSION: Among women with high-risk pregnancies, use of computerized cardiotocography for antenatal monitoring did not result in a significant increase in cesarean delivery compared with standard cardiotocography. The results of this single-center randomized trial require confirmation in multicenter studies.
引用
- Saccone G, Tagliaferri S, Grasso A, et al. Antenatal cardiotocography with and without computer analysis in high-risk pregnancy: a randomized clinical trial. Am J Obstet Gynecol MFM. 2020. PMID: 33451612. doi:10.1016/j.ajogmf.2020.100284
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。