卫生巾提取甲胎蛋白辅助早期妊娠流产判断
本前瞻性队列研究在学术医疗中心纳入五组患者,量化卫生巾收集的阴道血中甲胎蛋白(AFP)水平。活动性流产组与择期刮宫组AFP中位数分别为3.7 IU/mL和4,542 IU/mL,ROC分析显示 cutoff 0.61 IU/mL时检测活动性流产的敏感度93.7%、特异度97.8%。结论认为高水平的阴道AFP有助于当日识别活动性流产。
要点
- 卫生巾收集的阴道血可提取AFP用于检测。
- 活动性流产组阴道血AFP中位数为3.7 IU/mL。
- cutoff 0.61 IU/mL时敏感度93.7%、特异度97.8%。
核心结论
- 卫生巾收集的阴道血可提取AFP,高水平阴道AFP有助于当日检测活动性流产。
研究设计与样本
- 前瞻性队列研究,在学术医疗中心评估五组患者:活动性流产、未知位置妊娠、完全性流产或宫外孕、持续妊娠及择期刮宫。
- 活动性流产组n=16,择期刮宫组n=24,持续妊娠组n=35,未知位置妊娠组n=12,完全性流产或宫外孕组n=10。
主要发现
- 活动性流产组阴道血AFP中位数3.7 IU/mL(范围0.5-739.2),择期刮宫组4,542 IU/mL(范围15.6-100,000)。
- 择期刮宫和活动性流产病例中除1例外均检测到AFP;持续妊娠组35例中仅2例检测到AFP。
- 未知位置妊娠组和完全性流产或宫外孕组均未检测到AFP。
- ROC分析显示检测活动性流产的敏感度93.7%、特异度97.8%(cutoff 0.61 IU/mL;曲线下面积0.96)。
关键数值与推荐
- 检测活动性流产的cutoff值为0.61 IU/mL,敏感度93.7%,特异度97.8%,曲线下面积0.96。
- 活动性流产组阴道血AFP中位数3.7 IU/mL(范围0.5-739.2),择期刮宫组4,542 IU/mL(范围15.6-100,000)。
临床怎么用
- 高水平的阴道AFP可辅助当日识别活动性流产,有助于区分活动性流产与持续妊娠、完全性流产及宫外孕。
- 该检测可能减少不确定性、焦虑水平及重复就诊次数。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To determine if high alpha-fetoprotein (AFP) level in vaginal blood collected on a sanitary pad can assist with detecting an active miscarriage. DESIGN: A prospective cohort study. SETTING: Academic medical center. PATIENT(S): Five groups were evaluated: women with active miscarriage, pregnancy of unknown location, completed miscarriage or extrauterine pregnancy (EUP), ongoing pregnancy, and undergoing elective dilation and curettage (D&C). INTERVENTION(S): None. MAIN OUTCOME MEASURE(S): For each patient, AFP level in the vaginal blood collected on a sanitary pad was quantified. RESULT(S): The vaginal blood AFP median levels (and their ranges) were 3.7 IU/mL (0.5-739.2) and 4,542 IU/mL (15.6-100,000) in the active miscarriage (n = 16) and the elective D&C (n = 24) groups, respectively. Alpha-fetoprotein was detected in all elective D&C and active miscarriage cases except in 1 case. In the ongoing pregnancy group (n = 35), only 2 of 35 specimens showed detectable AFP levels. In the pregnancy of unknown location (n = 12) and the completed miscarriage or EUP (n = 10) groups, no AFP was detected. Receiver operating characteristic analysis demonstrated 93.7% sensitivity and 97.8% specificity for the detection of an active miscarriage (cutoff 0.61 IU/mL; area under the curve 0.96). CONCLUSION(S): Alpha-fetoprotein can be extracted from vaginal blood collected on sanitary pads. A high level of vaginal AFP can assist with the same-day detection of an active miscarriage. This novel test is useful in differentiating active miscarriages from ongoing pregnancies, completed miscarriages, and EUPs and, therefore, it reduces uncertainty, anxiety level, and number of repeat office visits.
引用
- Mor A, Gardezi M, Jubanyik K, et al. Miscarriage determination in first trimester based on alpha-fetoprotein extracted from sanitary pads. Fertil Steril. 2021. PMID: 33461753. doi:10.1016/j.fertnstert.2020.10.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。