文献速递产科母胎医学

肾动脉多普勒评估单绒毛膜双羊膜囊双胎及双胎输血综合征

Renal artery Doppler studies in the assessment of monochorionic, diamniotic twin pregnancies with and without twin-twin transfusion syndrome.
PubMed 文献 · Am J Obstet Gynecol MFM · 2020-07-01

这项前瞻性研究纳入12例双胎输血综合征(TTTS)供血儿和12例胎龄匹配的单绒毛膜双羊膜囊(MCDA)双胎对照,评估肾动脉多普勒参数。结果显示供血儿肾动脉收缩期峰值流速(PSV)显著低于对照,双胎间PSV比值在TTTS组显著升高,以>1.35为界值诊断TTTS的敏感度92%、特异度100%;激光治疗后PSV比值可能恢复正常。

要点

  • TTTS供血儿肾动脉PSV显著低于MCDA对照,受血儿与对照无差异。
  • 双胎间肾动脉PSV比值TTTS组高于对照,>1.35诊断TTTS敏感度92%、特异度100%。
  • 激光治疗后双胎间PSV比值可能恢复正常,与对照无差异。

核心结论

  • TTTS与无TTTS的MCDA双胎之间肾动脉PSV比值存在差异,可能由供血儿肾动脉PSV改变驱动。
  • 激光治疗可能使肾动脉PSV比值及供血儿肾动脉PSV恢复正常。

研究设计与样本

  • 前瞻性研究,纳入TTTS的MCDA双胎妊娠与胎龄匹配的无TTTS的MCDA双胎对照妊娠。
  • 共纳入12例供血儿和12例对照,对每个胎儿行肾动脉多普勒测量搏动指数、阻力指数和PSV。
  • 计算TTTS组受血儿与供血儿的双胎间比值,并与对照组双胎间比值比较。

主要发现

  • 供血儿肾动脉PSV中位数14.24(11.51-15.36)显著低于对照中位数24.79(22.46-27.03),P<.0004。
  • 供血儿与对照的肾动脉搏动指数和阻力指数无差异。
  • 受血儿与对照的肾动脉搏动指数、阻力指数和PSV均无差异。
  • TTTS组双胎间PSV比值中位数1.70(1.53-2.02)显著高于对照中位数1.06(1.03-1.15),P=.002。
  • 以PSV比值>1.35诊断TTTS,正确分类11/12例TTTS和全部12例对照,敏感度92%、特异度100%。

关键数值与推荐

  • 肾动脉PSV比值>1.35用于诊断TTTS:敏感度92%、特异度100%。
  • 供血儿肾动脉PSV中位数14.24(11.51-15.36)vs 对照24.79(22.46-27.03),P<.0004。
  • 双胎间PSV比值中位数TTTS组1.70(1.53-2.02)vs 对照1.06(1.03-1.15),P=.002。
  • 激光前PSV比值均值1.46(标准差0.37)vs 激光后0.87(标准差0.37),P=.02。

临床怎么用

  • 肾动脉PSV比值可作为TTTS诊断的辅助指标,但需进一步研究验证。
  • 激光治疗后肾动脉PSV比值可能恢复正常,或可用于评估胎儿对激光治疗的反应。

局限性

  • 样本量小(12例供血儿和12例对照),结论需更大样本验证。
  • 激光治疗亚组仅4例,结果解释需谨慎。
  • 肾动脉PSV在TTTS预测、诊断或分期中的效用尚待进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In monochorionic, diamniotic twin pregnancies complicated by twin-twin transfusion syndrome, imbalanced fetofetal blood shunting and discordant activation of the renin-angiotensin system result in a hypovolemic, oliguric donor twin and a hypervolemic, polyuric recipient twin. Renal artery Doppler assessments have been reported to predict oligohydramnios in singleton pregnancies; however, their value in assessing monochorionic, diamniotic twin gestations, including pregnancies complicated by twin-twin transfusion syndrome, remains unstudied. OBJECTIVE: This investigation evaluated whether renal artery Doppler parameters are different between sets of monochorionic, diamniotic twins with and without twin-twin transfusion syndrome. STUDY DESIGN: We conducted a prospective study of women with monochorionic, diamniotic twin pregnancies complicated by twin-twin transfusion syndrome and women with gestational-age matched monochorionic, diamniotic twin control pregnancies without twin-twin transfusion syndrome. For each twin, renal artery Doppler assessment was performed from a coronal view of the fetus, and pulsatility index, resistive index, and peak systolic velocity were measured. In twin pairs complicated by twin-twin transfusion syndrome, renal artery Doppler pulsatility index, resistive index, and peak systolic velocity intertwin ratios were calculated by comparing paired recipient-to-donor values. Similar ratios were calculated for control twin pairs. We compared each measurement between donors and controls and between recipients and controls. Intertwin ratios were compared between twin-twin transfusion syndrome cases and monochorionic, diamniotic controls. Our primary outcome was a comparison of renal artery Doppler pulsatility index measurement between donor fetuses in twin-twin transfusion syndrome cases and matched control twins. Secondary outcomes included comparisons of other renal artery Doppler parameters between twin-twin transfusion syndrome donor twins and controls and between twin-twin transfusion syndrome recipients and controls and comparisons of the renal artery Doppler parameter ratios between twin-twin transfusion syndrome and non-twin-twin transfusion syndrome twin pair groups. Finally, we performed a subgroup analysis involving pregnancies with twin-twin transfusion syndrome that underwent fetoscopic laser therapy and resulted in twin survivors to evaluate if laser therapy influenced renal artery Doppler findings. RESULTS: We recruited 12 donors and 12 controls. Renal artery Doppler pulsatility index and resistive index did not differ between donors and controls. However, donor renal artery Doppler peak systolic velocity (median, 14.24 [11.51-15.36]) was significantly lower than that of controls (median, 24.79 [22.46-27.03]; P<.0004). When recipient twins were compared with controls, there was no difference in renal artery Doppler pulsatility index, renal artery Doppler resistive index, or renal artery Doppler peak systolic velocity. Renal artery Doppler peak systolic velocity ratios were significantly higher among cases with twin-twin transfusion syndrome (median, 1.70 [1.53-2.02]) than controls (median, 1.06 [1.03-1.15]; P=.002). Applying a renal artery Doppler peak systolic velocity ratio cutoff of >1.35 for the diagnosis of twin-twin transfusion syndrome correctly classified 11 of 12 cases with twin-twin transfusion syndrome and all 12 controls without twin-twin transfusion syndrome (92% sensitivity and 100% specificity). Among donors with twin-twin transfusion syndrome with double survivors after undergoing laser therapy (n=4), prelaser renal artery Doppler peak systolic velocity ratios (mean, 1.46; standard deviation, 0.37) were significantly higher than postlaser renal artery Doppler peak systolic velocity ratios (mean, 0.87; standard deviation=0.37; P=.02). Postlaser intertwin renal artery Doppler peak systolic velocity ratios did not differ from control twin pairs (P=.125). CONCLUSION: Renal artery Doppler peak systolic velocity ratios differ between monochorionic, diamniotic twins with twin-twin transfusion syndrome and those without twin-twin transfusion syndrome. This effect seems to be driven by altered donor twin renal artery Doppler peak systolic velocity. Laser therapy may normalize renal artery Doppler peak systolic velocity ratios and donor twin renal artery Doppler values to those observed in monochorionic, diamniotic twins without twin-twin transfusion syndrome. Further study is warranted to explore whether renal artery Doppler peak systolic velocity has utility as a tool for twin-twin transfusion syndrome prediction, diagnosis, or staging, and fetal response to laser therapy.

来源:Am J Obstet Gynecol MFM,查看原文。版权归原作者所有。

引用

  1. Jain JA, Gyamfi-Bannerman C, Simpson LL, et al. Renal artery Doppler studies in the assessment of monochorionic, diamniotic twin pregnancies with and without twin-twin transfusion syndrome. Am J Obstet Gynecol MFM. 2020. PMID: 33345886. doi:10.1016/j.ajogmf.2020.100167

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。