文献速递产科

盲放与直视放置Foley球囊导管的随机对照试验

Foley Bulb Insertion by Blind Placement Compared With Direct Visualization: A Randomized Controlled Trial.
PubMed 文献 · Obstet Gynecol · 2021-01-01

一项开放标签非劣效随机试验纳入372例宫颈条件不佳的引产孕妇,比较手指盲放与无菌窥器放置球囊导管。盲放组与窥器组母体感染复合率分别为15.7%和12.8%,绝对差2.8%(95%CI -4.3至9.9%),符合预设非劣效界值;窥器组需第二次球囊导管的比例更高,两组满意度及疼痛无差异。

要点

  • 手指盲放球囊导管在母体感染方面非劣效于无菌窥器放置。
  • 窥器组需要第二次机械扩张器的比例更高。
  • 两组在产妇及新生儿不良事件、放置疼痛和满意度上无差异。

核心结论

  • 对于引产前宫颈成熟的球囊导管放置,手指盲放法在母体感染方面非劣效于无菌窥器法。
  • 盲放手指法是球囊放置的合理选择。

研究设计与样本

  • 开放标签非劣效随机对照试验,纳入372例宫颈条件不佳(扩张小于3cm且消退小于60%)的引产孕妇。
  • 随机分为手指盲放组(185例)和无菌窥器组(187例)。
  • 主要结局为母体感染复合终点,包括发热(体温38°C或以上)、绒毛膜羊膜炎或子宫内膜炎。
  • 基于10%非劣效界值和10%预期主要结局频率,需要372例样本(90%把握度,90%方案依从性)。

主要发现

  • 盲放组母体感染复合率为15.7%,窥器组为12.8%,绝对差2.8%(95%CI -4.3至9.9%),符合非劣效界值。
  • 除窥器组需要第二次球囊导管的比例更高外,其他次要结局两组无差异。
  • 两组产妇和新生儿不良事件无差异。
  • 窥器组更多女性在下次妊娠时会选择手指盲放法(37.6% vs 25.7%;P=.02)。

关键数值与推荐

  • 非劣效界值为10%,主要结局绝对差2.8%(95%CI -4.3至9.9%),上限低于10%。
  • 盲放组母体感染复合率15.7%,窥器组12.8%。
  • 窥器组下次妊娠选择手指盲放法的比例为37.6%,盲放组为25.7%(P=.02)。

临床怎么用

  • 手指盲放球囊导管可作为引产前宫颈成熟的合理放置方式,不增加母体感染风险。
  • 窥器放置可能需要更频繁地更换球囊导管。

局限性

  • 开放标签设计可能影响患者满意度等主观结局。
  • 主要结局诊断由管理产科医生或助产士作出,可能存在判断偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To test the hypothesis that digital placement of a balloon catheter is not inferior to the speculum method in terms of rate of maternal infection. METHODS: In an open-label noninferiority randomized trial, pregnant women who were undergoing induction of labor with unfavorable cervix (less than 3 cm dilated and less than 60% effaced) were randomly assigned to balloon catheter that was placed either digitally or using a sterile speculum. The primary outcome was a composite of maternal infection, defined by occurrence of fever (temperature 38°C or higher), chorioamnionitis, or endometritis (diagnoses were made by the managing obstetric physician or midwife). Prespecified secondary outcomes included outcomes in the primary composite, cesarean delivery rates, and maternal and neonatal outcomes. A patient satisfaction survey was also obtained. On the basis of a noninferiority margin of 10% and an expected primary outcome frequency of 10%, a sample size of 372 women was needed (90% power to confirm noninferiority with 90% protocol adherence). RESULTS: From February 2018 through February 2019, 372 women were randomized (185 digital placement, 187 sterile speculum). Baseline characteristics were similar between groups. The composite maternal infection rate was not different between groups (digital placement arm: 15.7% vs speculum arm: 12.8%), with an absolute difference with respect to the sterile speculum arm of 2.8% (95% CI -4.3 to 9.9%), indicating noninferiority for the prespecified margin. Secondary outcomes were not different between groups, except for a higher need for a second balloon catheter in the sterile speculum arm. Maternal and neonatal adverse events were not different between groups. Irrespective of method of placement, women were equally satisfied with the explanation of the method before placement, anxiety regarding the procedure, and pain during placement. More women in the sterile speculum group would choose the digital placement method for the subsequent pregnancy (37.6% vs 25.7%; P=.02.). CONCLUSION: Digital placement of a balloon catheter for preinduction cervical ripening is noninferior to the sterile speculum method, in terms of maternal infection. Women in the sterile speculum group more frequently required a second round of the mechanical dilator. The blind digital approach is a reasonable option for balloon placement for cervical ripening. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov, NCT03450408.

来源:Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Kuhlmann MJ, Spencer N, Garcia-Jasso C, et al. Foley Bulb Insertion by Blind Placement Compared With Direct Visualization: A Randomized Controlled Trial. Obstet Gynecol. 2021. PMID: 33278290. doi:10.1097/AOG.0000000000004182

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。