先天性中枢性低通气综合征患者的妊娠管理
该研究通过匿名横断面调查10例先天性中枢性低通气综合征(CCHS)患者的妊娠情况,发现部分患者妊娠期间需调整通气支持,膈肌起搏器使用者在妊娠晚期或剖宫产后出现不适,强调多导睡眠监测和产前CCHS检测的重要性。
要点
- CCHS患者妊娠期间可能需调整通气设置或更换通气方式。
- 多导睡眠监测应作为妊娠期评估夜间通气的常规手段。
- 使用膈肌起搏器者需警惕妊娠晚期及剖宫产后不适。
核心结论
- CCHS女性妊娠期间可能面临通气维持问题,需调整呼吸机参数或更换通气方式。
研究设计与样本
- 匿名横断面调查,纳入10例有妊娠史的CCHS女性,问卷共26项。
主要发现
- 10例妊娠中3例需调整基线通气支持。
- 2例膈肌起搏器使用者在妊娠晚期或剖宫产后因不适而停用起搏器。
- 1例因停用起搏器且未识别替代通气需求导致呼吸骤停需紧急复苏。
- 10例妊娠中9例足月成功分娩,5例婴儿诊断为CCHS。
关键数值与推荐
- 所有被提供产前CCHS检测的患者均选择接受检测。
临床怎么用
- 妊娠早期应讨论通气需求变化的预见性指导和应急计划。
- 应提供产前CCHS检测以指导分娩决策和新生儿高级护理准备。
局限性
- 样本量小(仅10例响应),为匿名横断面调查,可能存在回忆偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Congenital central hypoventilation syndrome is a rare genetic disorder of autonomic regulation of breathing resulting from mutations in the paired-like homeobox gene. Individuals with congenital central hypoventilation syndrome demonstrate an absent or diminished physiological response to hypercapnia and hypoxia that is most severe during sleep and depend on mechanical ventilation to maintain normal gas exchange. Increased disease awareness and availability of paired-like homeobox gene testing has improved congenital central hypoventilation syndrome morbidity and mortality, and patients are now living into adulthood. During pregnancy, delivery, and the postpartum period, women with congenital central hypoventilation syndrome are vulnerable to developing respiratory insufficiency. Currently, there is no standardized approach to monitoring ventilatory status and anticipating the need for changes to existing ventilatory support for women with congenital central hypoventilation syndrome during pregnancy, labor, and delivery. OBJECTIVE: This study aimed to characterize current practices for monitoring ventilatory status and managing ventilatory needs in women with congenital central hypoventilation syndrome during pregnancy; identify specific circumstances through which ventilation may be compromised during pregnancy, delivery, and postpartum; evaluate utilization of prenatal congenital central hypoventilation syndrome testing; and report any adverse pregnancy outcomes. STUDY DESIGN: We conducted an anonymous cross-sectional survey of women with congenital central hypoventilation syndrome with current or prior pregnancy. The 26-item electronic questionnaire included questions on congenital central hypoventilation syndrome genotype; number and outcome of pregnancies; use of mechanical ventilation; and issues with or adjustments made to ventilation during pregnancy, delivery, and the postpartum period. RESULTS: We received 10 responses. Three patients were not diagnosed with congenital central hypoventilation syndrome until after pregnancy and delivery. The 7 patients with a preexisting congenital central hypoventilation syndrome diagnosis reported information on 10 total pregnancies. At baseline, patients relied on various types of ventilatory support including positive pressure ventilation via tracheostomy, bilevel noninvasive positive pressure ventilation, and diaphragm pacing by phrenic nerve stimulation. Polysomnography for objective assessment of nocturnal ventilation was not consistently utilized. Changes to baseline ventilatory support were required during 3 out of 10 pregnancies. In addition, 2 patients using diaphragm pacing reported discomfort with pacing during the third trimester or after cesarean delivery, prompting discontinuation of diaphragm pacing. In 1 instance, discontinuation of diaphragm pacing and lack of recognition of need for an alternative support method led to respiratory arrest and need for emergent resuscitation. All patients who were offered prenatal congenital central hypoventilation syndrome testing chose to undergo testing. Of note, 9 out of 10 pregnancies were carried successfully to term and 5 infants were diagnosed with congenital central hypoventilation syndrome. CONCLUSION: Women with congenital central hypoventilation syndrome may experience issues maintaining adequate ventilation during pregnancy, necessitating an adjustment of ventilator settings or use of an alternative type of ventilation. Objective assessment of nocturnal ventilation by means of polysomnography is an important part of congenital central hypoventilation syndrome pregnancy care to optimize maintenance of adequate gas exchange. Patients who rely on diaphragm pacing may experience discomfort with pacing during the later stages of pregnancy and after cesarean delivery. Anticipatory guidance and contingency planning for changing ventilatory needs should be discussed early in pregnancy. Prenatal congenital central hypoventilation syndrome testing should be offered to pregnant patients with congenital central hypoventilation syndrome to inform delivery decisions and prepare for the provision of advanced neonatal care.
引用
- Maloney MA, Keens TG, Vanderlaan MB, et al. Pregnancy in congenital central hypoventilation syndrome. Am J Obstet Gynecol MFM. 2020. PMID: 33345936. doi:10.1016/j.ajogmf.2020.100237
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。