文献速递妇科

子宫内膜癌前哨淋巴结检测的解剖不对称性

Anatomic Asymmetry in Sentinel Lymph Node Detection in Endometrial Cancer.
PubMed 文献 · J Minim Invasive Gynecol · 2020-12-26

该回顾性队列研究纳入111例子宫内膜癌患者,比较Tc99m-FSC、ICG单用或联用的前哨淋巴结检出率及双侧解剖对称性。结果显示联用可能获得最佳双侧检出率,但双侧检出者中仅43.8%存在对称解剖一致,单侧失败时不能依据对侧淋巴结位置取材。

要点

  • 联用放射性同位素与ICG可能获得最佳双侧前哨淋巴结检出率。
  • ICG单用双侧检出率高于Tc99m-FSC(75% vs 63.4%)。
  • 双侧检出者中仅43.8%存在盆腔解剖对称一致,单侧失败时不可依赖对侧位置。

核心结论

  • 术前放射性同位素注射联合术中ICG给药可能获得最佳双侧前哨淋巴结检出率。
  • 单侧映射失败时不能依赖已检出同侧前哨淋巴结的解剖位置来采集互补淋巴结,因对称一致性差。

研究设计与样本

  • 回顾性队列研究,纳入2014至2019年以色列Holon三级学术医疗中心111例子宫内膜癌患者。
  • 101例(91.9%)使用Tc99m-FSC行前哨淋巴结映射,64例(57.6%)注射ICG,其中55例(49.5%)同时使用两种方法。

主要发现

  • 单侧前哨淋巴结总检出率为96.4%;ICG为96.9%,γ探头为93.1%,两者联用为98.2%。
  • 总双侧检出率为72.1%,ICG单用高于Tc99m-FSC(75% vs 63.4%)。
  • 55例同时使用两种示踪剂者,双侧检出率显著高于单用Tc99m-FSC。
  • 80例实现双侧前哨淋巴结检出者中,仅35例(43.8%)存在盆腔解剖对称一致。

临床怎么用

  • 可考虑术前放射性同位素联合术中ICG以提高双侧前哨淋巴结检出率。
  • 单侧映射失败时,不应依据对侧已检出前哨淋巴结的解剖位置来指导互补淋巴结取材。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY OBJECTIVE: To determine whether the concomitant use of indocyanine green (ICG) with technetium-99m-filtered sulfur colloid (Tc99m-FSC) improves bilateral sentinel lymph node (SLN) detection rate in endometrial cancer and whether anatomic concordance of pelvic lymph nodes exists and can be used to predict SLN location in cases of unilateral mapping failure. DESIGN: Retrospective cohort study. SETTING: Tertiary academic medical center in Holon, Israel. PATIENTS: Patients diagnosed with endometrial cancer, who underwent SLN mapping with Tc99m-FSC, ICG, or both, at our center between 2014 and 2019. INTERVENTIONS: A total of 111 patients were included in the study. SLN mapping using Tc99m-FSC was performed in 101 (91.9%) patients, and ICG injection was given to 64 (57.6%) patients of whom 55 (49.5%) received both. We compared SLN detection rates (unilateral and bilateral) and anatomic symmetry for each method alone and for a combination of the 2. MEASUREMENTS AND MAIN RESULTS: The overall detection rate for unilateral SLNs was 96.4%; 96.9% with ICG, 93.1% with gamma-probe, and 98.2% by combining both methods. The total bilateral detection rate was 72.1%, with ICG performing better as a single tracer than Tc99m-FSC (75% vs 63.4%, respectively). In 55 women in whom both tracers were used, the bilateral detection rate was significantly higher compared with Tc99m-FSC alone. Symmetric pelvic anatomic concordance of SLN was found in only 35 of 80 patients with bilateral SLN detection (43.8%). CONCLUSION: The combination of preoperative radioisotope injection and intraoperative ICG administration may yield the best bilateral SLN detection rate. In cases of unilateral mapping failure, one cannot rely on the anatomic location of the ipsilateral SLN detected to harvest the complementary node because the symmetric concordance is poor.