经阴道宫颈环扎缝线粗细与妊娠结局的关联
这项回顾性队列研究纳入203例单胎非畸形妊娠、行经阴道宫颈环扎的孕妇,比较粗缝线(5mm编织聚酯纤维Mersilene带)与细缝线(Ethibond或Prolene)的妊娠结局。调整混杂因素后,粗缝线在超声指征和体格检查指征环扎者中与更长的妊娠时长相关,并与更低的34周前早产、绒毛膜羊膜炎和新生儿重症监护室入住几率相关。
要点
- 粗缝线与超声指征(aHR 0.61,95%CI 0.41-0.91)和体格检查指征(aHR 0.30,95%CI 0.15-0.58)环扎者妊娠时长延长相关。
- 粗缝线与更低的34周前早产、绒毛膜羊膜炎和新生儿重症监护室入住几率相关。
- 粗缝线在病史指征环扎者中与妊娠时长无显著关联(aHR 1.27,95%CI 0.83-1.94)。
核心结论
- 粗缝线相比细缝线在超声指征和体格检查指征经阴道宫颈环扎者中与更长的妊娠时长相关,并与更低的绒毛膜羊膜炎和新生儿重症监护室入住几率相关,无论环扎指征如何。
研究设计与样本
- 回顾性队列研究,纳入2013-2016年单中心203例单胎非畸形妊娠行经阴道宫颈环扎的孕妇,其中粗缝线120例(59%)、细缝线83例(41%)。
主要发现
- 调整混杂因素后,粗缝线与超声指征环扎者更长妊娠时长相关(aHR 0.61,95%CI 0.41-0.91),与体格检查指征环扎者更长妊娠时长相关(aHR 0.30,95%CI 0.15-0.58)。
- 粗缝线与病史指征环扎者妊娠时长无显著关联(aHR 1.27,95%CI 0.83-1.94)。
- 粗缝线与更低的34周前早产、绒毛膜羊膜炎和新生儿重症监护室入住几率相关。
临床怎么用
- 对于超声指征或体格检查指征的经阴道宫颈环扎,可考虑选用5mm编织聚酯纤维粗缝线以延长妊娠时长并降低相关新生儿并发症。
局限性
- 回顾性队列设计、单中心、样本量有限,缝线类型由术者自主选择,可能存在选择偏倚和混杂。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Cervical cerclage placement has been shown to benefit women who have cervical insufficiency, however, the best type of suture to use for transvaginal cerclage placement is unknown. OBJECTIVE: To evaluate the association between transvaginal cerclage suture thickness and pregnancy outcomes. STUDY DESIGN: Retrospective cohort study of women with a singleton, non-anomalous gestation who underwent history-, ultrasound- or physical exam-indicated transvaginal cerclage at a single tertiary care center (2013-2016). The primary outcome was gestational age at delivery. Secondary outcomes included preterm birth less than 34 weeks, chorioamnionitis, neonatal intensive care unit admission and composite neonatal morbidity. Baseline characteristics and outcomes were compared by thickness of suture material: thick 5mm braided polyester fiber (Mersilene® tape) versus thin polyester braided thread (Ethibond®) or polypropylene non-braided monofilament (Prolene®) with selection of suture type at the discretion of the provider. The association between thick suture and gestational age at delivery was estimated using Cox proportional hazard regression. Multivariable logistic regression was used to estimate the association between thick suture and the secondary outcomes. Effect modification of cerclage indication was also assessed. RESULTS: A total of 203 women met inclusion criteria: 120 (59%) with thick suture and 83 (41%) with thin suture. Of these, 130 women had history-indicated, 35 had ultrasound-indicated, and 38 had exam-indicated cerclages. Compared to women who had thin suture, women with thick suture were more likely to have had a history- or ultrasound-indicated cerclage, rather than exam-indicated cerclage, and more likely to have had a Shirodkar or cervico-isthmic approach, rather than McDonald. Women with thick suture were also more likely to have received progesterone and had placement at earlier gestational age, but there were no differences in cervical exam at placement. After adjusting for confounding factors, thick suture was associated with longer pregnancy duration among women with ultrasound-indicated cerclage (aHR 0.61, 95%CI 0.41-0.91) and exam-indicated cerclage (aHR 0.30, 95%CI 0.15-0.58), but not with history-indicated cerclage (aHR 1.27, 95%CI 0.83-1.94). Thick suture was also associated with lower odds of preterm birth < 34 weeks, chorioamnionitis and neonatal intensive care unit admission, compared to thin suture. CONCLUSION: Thick, compared to thin suture, for transvaginal cervical cerclage was associated with longer duration of pregnancy among women with ultrasound- and exam-indicated cerclages and lower odds of chorioamnionitis and neonatal intensive care unit admission among all women regardless of cerclage indication.
引用
- Battarbee AN, Pfister A, Manuck TA, et al. Suture thickness and transvaginal cervical cerclage outcomes. Am J Obstet Gynecol MFM. 2019. PMID: 33179009. doi:10.1016/j.ajogmf.2019.100056
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。