文献速递产科母胎医学

出生体重对35-37周胎儿心脏指数的影响

Influence of birth weight on fetal cardiac indices at 35-37 weeks' gestation.
PubMed 文献 · Ultrasound Obstet Gynecol · 2020-12-31

这项前瞻性研究纳入1498例单胎妊娠,在35+0至36+6周行超声检查,发现出生体重Z评分与右心室球形指数、左右心室收缩功能及E/A比值呈线性相关,而与子宫动脉搏动指数和脑胎盘比无显著关联,提示小胎儿的心脏差异可能是对体型变化的正常生理反应。

要点

  • 出生体重是胎儿心脏形态和功能的决定因素,但子宫动脉搏动指数和脑胎盘比不是。
  • 小于胎龄儿和胎儿生长受限胎儿右心室更呈球形,左右心室收缩功能减低,E/A比值增高。
  • 胎儿心脏指数差异可能反映对胎儿体型变化的正常生理反应,而非胎盘灌注异常的病理适应。

核心结论

  • 出生体重是胎儿心脏形态和功能的决定因素,而子宫动脉搏动指数和脑胎盘比作为胎盘灌注和胎儿氧合的间接指标则不是。

研究设计与样本

  • 前瞻性研究纳入1498例单胎妊娠妇女,在35+0至36+6周妊娠行常规超声检查,排除孕前或妊娠期糖尿病、慢性高血压、妊娠期高血压或子痫前期。

主要发现

  • 研究人群包括146例(9.7%)小于胎龄儿(出生体重<第10百分位)和68例(4.5%)胎儿生长受限。
  • 与对应非小于胎龄儿和非胎儿生长受限胎儿相比,小于胎龄儿和胎儿生长受限胎儿右心室更呈球形、左右心室收缩功能减低,左心室舒张功能指标E/A比值增高。
  • 右心室球形指数、左右心室收缩功能指标及E/A比值与出生体重Z评分呈线性关联。
  • 心脏形态和功能指标与子宫动脉搏动指数Z评分或脑胎盘比Z评分无显著关联。

临床怎么用

  • 临床解读小胎儿心脏指数差异时,应考虑其可能是对胎儿体型变化的正常生理反应,而非胎盘灌注异常的病理适应。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Echocardiographic studies have reported that fetuses with low birth weight, compared to those with normal birth weight, have globular hearts and reduced cardiac function. Dichotomizing continuous variables, such as birth weight, may be helpful in describing pathology in small studies but can prevent us from identifying physiological responses in relation to change in size. The aim of this study was to explore associations between fetal cardiac morphology and function and birth weight, as a continuous variable, as well as uterine artery (UtA) pulsatility index (PI), as an indirect measure of placental perfusion, and the cerebroplacental ratio (CPR), as an indirect measure of fetal oxygenation. METHODS: This was a prospective study of 1498 women with singleton pregnancy undergoing routine ultrasound examination at 35 + 0 to 36 + 6 weeks' gestation. Pregnancies complicated by pregestational or gestational diabetes mellitus, chronic hypertension, pregnancy-induced hypertension or pre-eclampsia were excluded from the analysis. Conventional and more advanced echocardiographic modalities, such as speckle tracking, were used to assess fetal cardiac function in the right and left ventricles. The morphology of the fetal heart was assessed by calculating the right and left sphericity indices. In addition, the PI of the UtA, umbilical artery (UA) and fetal middle cerebral artery (MCA) was determined and the CPR was calculated by dividing MCA-PI by UA-PI. Multiple linear regression models were used to assess determinants of fetal echocardiographic parameters. RESULTS: The study population included 146 (9.7%) small-for-gestational-age (SGA) fetuses with birth weight < 10th percentile and 68 (4.5%) with fetal growth restriction (FGR). In the SGA and FGR groups, compared to the non-SGA and non-FGR fetuses, respectively, there was a more globular right ventricle and reduced left and right ventricular systolic function, and, from the left ventricular diastolic functional indices, the E/A ratio was increased. There was a linear association of right ventricular sphericity index, indices of left and right ventricular systolic function and E/A ratio with birth-weight Z-score. There were no significant associations between cardiac morphological and functional indices and UtA-PI Z-score or CPR Z-score. CONCLUSIONS: This screening study at 35-37 weeks' gestation has demonstrated that birth weight is a determinant of fetal cardiac morphology and function but UtA-PI and CPR, as indirect measures of placental perfusion and fetal oxygenation, are not. This suggests that the differences in fetal cardiac indices between small and appropriately grown fetuses may be part of a normal physiological response to change in fetal size rather than part of a pathological adaptation to abnormal placental perfusion and fetal oxygenation. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Semmler J, Abdel-Azim S, Anzoategui S, et al. Influence of birth weight on fetal cardiac indices at 35-37 weeks' gestation. Ultrasound Obstet Gynecol. 2020. PMID: 33094501. doi:10.1002/uog.23522

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。