文献速递妇科产科

微创根治性子宫切除术中新型举宫方法的开发

The Development of a New Uterine Manipulation Method during Minimally Invasive Radical Hysterectomy.
PubMed 文献 · J Minim Invasive Gynecol · 2020-09-24

本研究为回顾性研究,在2家医院对8例早期宫颈癌患者行腹腔镜或机器人根治性子宫切除术时,使用新型U-traction装置(65-mm半弯切割针与2.5-mm聚酯带,长45 cm)进行举宫。举宫均成功且安全,无并发症,应用时间少于5分钟,所有病例均避免了阴道举宫器、额外穿刺孔及助手举宫。

要点

  • U-traction装置由65-mm半弯切割针和2.5-mm聚酯带(长45 cm)组成,用于微创根治性子宫切除术中举宫。
  • 8例宫颈癌患者行腹腔镜或机器人根治性子宫切除术中,使用U-traction举宫均成功且安全,无并发症。
  • 应用时间少于5分钟,所有病例均避免了阴道举宫器、额外穿刺孔及助手举宫。

核心结论

  • 新型U-traction装置可在微创根治性子宫切除术中实现简便且可重复的举宫。
  • 使用该装置可避免阴道举宫器,且无需助手举宫即可安全完成微创根治性子宫切除术。

研究设计与样本

  • 回顾性研究,在1家大学医院和1家三级护理医院开展。
  • 研究对象为接受微创根治性子宫切除术的早期宫颈癌患者,共8例。

主要发现

  • 在8例宫颈癌患者的腹腔镜或机器人根治性子宫切除术中,使用U-traction装置举宫均成功且安全,无任何并发症。
  • U-traction的应用时间少于5分钟。
  • 所有病例均避免了使用阴道举宫器、为额外穿刺孔增加切口以及需要助手医师举宫。

关键数值与推荐

  • U-traction装置由65-mm半弯切割针和2.5-mm聚酯带(长45 cm)组成。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY OBJECTIVE: The use of a vaginal uterine manipulator may compromise the oncological outcomes of patients with cervical cancer undergoing minimally invasive radical hysterectomy (MIS-RH). We aimed to describe the safety and efficacy of a novel uterine manipulation device during MIS-RH. DESIGN: Retrospective study. SETTING: A university hospital and a tertiary care hospital. PATIENTS: Patients with early-stage cervical cancer who were treated with MIS-RH. INTERVENTIONS: We developed the U-traction, a new device that consists of a 65-mm half-curved cutting needle with a 2.5-mm polyester tape (45-cm long), and investigated its utility to manipulate the uterus during MIS-RH. MEASUREMENTS AND MAIN RESULTS: This study describes the utility and safety of the U-traction for uterine manipulation during laparoscopic or robotic RH in 8 patients with cervical cancer. Uterine manipulation was successfully and safely performed using the U-traction during laparoscopic or robotic RH in patients with cervical cancer without any complications. The application time was less than 5 minutes. In all cases, the use of a vaginal manipulator, an additional incision for an extra port, or the need for assistant surgeons for uterine manipulation was avoided. CONCLUSION: The novel U-traction device allows for easy and reproducible uterine manipulation during MIS-RH. With this device, the use of a vaginal uterine manipulator can be avoided, and MIS-RH can be safely performed without the need for an assistant surgeon for uterine manipulation.

来源:J Minim Invasive Gynecol,查看原文。版权归原作者所有。

引用

  1. Mabuchi S, Niiro E, Nagayasu M, et al. The Development of a New Uterine Manipulation Method during Minimally Invasive Radical Hysterectomy. J Minim Invasive Gynecol. 2020. PMID: 32979532. doi:10.1016/j.jmig.2020.09.015