脉冲波多普勒测量胎儿心脏充盈时间分数与射血时间分数:参考范围及潜在临床应用
本研究纳入602例低风险单胎妊娠与54例高风险胎儿(严重双胎输血综合征、主动脉瓣狭窄或主动脉缩窄),评估脉冲波多普勒测量胎儿充盈时间分数(FTF)与射血时间分数(ETF)的可行性及可重复性,建立参考范围,并分析其与心率、孕龄及估计胎儿体重的关系及在高风险胎儿中的Z值变化。
要点
- 低风险胎儿中95%可获得满意FTF和ETF多普勒波形,观察者内ICC 0.831-0.905,观察者间ICC 0.801-0.837。
- 低风险胎儿中FTF仅与心率相关,ETF与心率及孕龄相关;FTF随心率的降低而升高,ETF则随心率的降低而降低。
- 多数严重TTTS受血儿FTF降低而ETF保留;主动脉瓣狭窄左室FTF降低、ETF升高;多数主动脉缩窄胎儿双室FTF和ETF在正常范围。
核心结论
- 脉冲波多普勒测量胎儿FTF和ETF可行且可重复,所建立的参考范围考虑了FTF与心率及ETF与心率、孕龄的关联,这些时间分数可能有助于严重TTTS、主动脉瓣狭窄及其他心脏负荷过重胎儿情况的临床监测。
研究设计与样本
- 前瞻性低风险单胎妊娠队列及高风险胎儿人群(严重TTTS、主动脉瓣狭窄或主动脉缩窄),孕18至41周,共纳入602例低风险单胎妊娠和54例高风险胎儿(9对单绒毛膜双胎严重TTTS、16例主动脉瓣狭窄、20例主动脉缩窄)。
主要发现
- 低风险胎儿中95%可获得满足FTF和ETF分析的多普勒波形;观察者内ICC 0.831-0.905,观察者间ICC 0.801-0.837。
- 低风险胎儿多因素分析显示心率是FTF的唯一预测变量,ETF取决于心率与孕龄;FTF随心率的降低而升高,ETF随心率的降低而降低。
- 多数严重TTTS受血儿表现为FTF降低而ETF保留。
- 主动脉瓣狭窄与左室FTF降低及ETF升高相关,单心室与双心室出生后结局似乎呈现不同模式。
- 多数主动脉缩窄胎儿双室FTF和ETF均在正常范围。
关键数值与推荐
- FTF计算公式为(充盈时间/周期时间)×100,ETF计算公式为(射血时间/周期时间)×100,以瓣膜点击点为标志。
- 低风险胎儿中FTF仅与心率相关,ETF与心率及孕龄相关。
临床怎么用
- 作者认为,脉冲波多普勒测量的FTF和ETF可能有助于严重TTTS、主动脉瓣狭窄及其他心脏负荷过重胎儿情况的临床监测。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Fetal cardiac function can be evaluated using a variety of parameters. Among these, cardiac cycle time-related parameters, such as filling time fraction (FTF) and ejection time fraction (ETF), are promising but rarely studied. We aimed to report the feasibility and reproducibility of fetal FTF and ETF measurements using pulsed-wave Doppler, to provide reference ranges for fetal FTF and ETF, after evaluating their relationship with heart rate (HR), gestational age (GA) and estimated fetal weight (EFW), and to evaluate their potential clinical utility in selected fetal conditions. METHODS: This study included a low-risk prospective cohort of singleton pregnancies and a high-risk population of fetuses with severe twin-twin transfusion syndrome (TTTS), aortic stenosis (AoS) or aortic coarctation (CoA), from 18 to 41 weeks' gestation. Left ventricular (LV) and right ventricular inflow and outflow pulsed-wave Doppler signals were analyzed, using valve clicks as landmarks. FTF was calculated as: (filling time/cycle time) × 100. ETF was calculated as: (ejection time/cycle time) × 100. Intraclass correlation coefficients (ICC) were used to evaluate the intra- and interobserver reproducibility of FTF and ETF measurements in low-risk fetuses. The relationships of FTF and ETF with HR, GA and EFW were evaluated using multivariate regression analysis. Reference ranges for FTF and ETF were then constructed using the low-risk population. Z-scores of FTF and ETF in the high-risk fetuses were calculated and analyzed. RESULTS: In total, 602 low-risk singleton pregnancies and 54 high-risk fetuses (nine pairs of monochorionic twins with severe TTTS, 16 fetuses with AoS and 20 fetuses with CoA) were included. Adequate Doppler traces for FTF and ETF could be obtained in 95% of low-risk cases. Intraobserver reproducibility was good to excellent (ICC, 0.831-0.905) and interobserver reproducibility was good (ICC, 0.801-0.837) for measurements of all timing parameters analyzed. Multivariate analysis of FTF and ETF in relation to HR, GA and EFW in low-risk fetuses identified HR as the only variable predictive of FTF, while ETF was dependent on both HR and GA. FTF increased with decreasing HR in low-risk fetuses, while ETF showed the opposite behavior, decreasing with decreasing HR. Most recipient twins with severe TTTS showed reduced FTF and preserved ETF. AoS was associated with decreased FTF and increased ETF in the LV, with seemingly different patterns associated with univentricular vs biventricular postnatal outcome. The majority of fetuses with CoA had FTF and ETF within the normal range in both ventricles. CONCLUSIONS: Measurement of FTF and ETF using pulsed-wave Doppler is feasible and reproducible in the fetus. The presented reference ranges account for associations of FTF with HR and of ETF with HR and GA. These time fractions are potentially useful for clinical monitoring of cardiac function in severe TTTS, AoS and other fetal conditions overloading the heart. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Soveral I, Crispi F, Guirado L, et al. Fetal cardiac filling and ejection time fractions by pulsed-wave Doppler: reference ranges and potential clinical application. Ultrasound Obstet Gynecol. 2021. PMID: 32672395. doi:10.1002/uog.22152
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。