文献速递产科母胎医学

死后微聚焦计算机断层扫描用于无创尸检:超过250例人类胎儿的经验

Postmortem microfocus computed tomography for noninvasive autopsies: experience in >250 human fetuses.
PubMed 文献 · Am J Obstet Gynecol · 2020-07-16

本研究为单中心前瞻性观察性病例系列,纳入2016至2019年转诊行微聚焦CT的268例胎儿(体重2-350克,孕11-24周),评估微聚焦CT检测胎儿异常的范围及避免有创尸检率。微聚焦CT与产前超声完全一致219/266例(81.9%),心脏异常敏感度66.7%、特异度91.7%,避免有创尸检率192/221(86.9%)。

要点

  • 微聚焦CT可检出胎儿脑、胸、腹部异常,与产前超声完全一致率81.9%。
  • 心脏异常敏感度66.7%、特异度91.7%,部分病例微聚焦CT额外发现超声未显示的心脏、软组织或泌尿生殖异常。
  • 在有创尸检知情同意的221例中,仅29例(13.1%)实际接受尸检,避免率86.9%。

核心结论

  • 胎儿微聚焦CT成像是早期妊娠胎儿成像的可行且有价值工具,可避免有创尸检的需要。
  • 多数病例可确认产前诊断,并可能检出额外异常。

研究设计与样本

  • 单中心前瞻性观察性病例系列,纳入2016至2019年3年间所有转诊行微聚焦CT成像的胎儿。
  • 共纳入268例胎儿,体重2-350克,孕11-24周。
  • 由2名儿科放射科医师在尸检前报告影像,是否进行有创尸检由专科围产期病理学家判断并获父母知情同意。

主要发现

  • 268例中122例(45.5%)明确死因,其中64例(52.5%)存在胎儿异常。
  • 221例(82.5%)获有创尸检知情同意,但仅29例(13.1%)实际接受尸检,避免有创尸检率192/221(86.9%)。
  • 脑、胸部及腹部病变完全一致;心脏异常敏感度66.7%、特异度91.7%。
  • 微聚焦CT与产前超声完全一致219/266例(81.9%),部分一致21/266例(7.9%),不一致26/266例(10.5%),不一致多因微聚焦CT额外发现超声未显示的心脏、软组织或泌尿生殖异常。

临床怎么用

  • 胎儿微聚焦CT成像可作为早期妊娠胎儿无创尸检的可行工具,避免有创尸检。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Noninvasive imaging autopsy alternatives for fetuses weighing <500 grams are limited. Microfocus computed tomography has been reported as a viable option in small case series with the potential to avoid an invasive autopsy. Implementation of postmortem microfocus computed tomography in a large cohort as part of routine clinical service has yet been unreported, and realistic "autopsy prevention rates" are unknown. OBJECTIVE: This study aimed to describe the range of abnormalities detectable on fetal microfocus computed tomography in a clinical setting and additional findings identified on the antenatal ultrasound and to estimate the invasive autopsy avoidance rate (ie, cases in which imaging was sufficient to deem autopsy unnecessary). STUDY DESIGN: A prospective observational case series of all fetuses referred for microfocus computed tomography imaging at a single institution was conducted for 3 years (2016-2019). Imaging was reported by 2 pediatric radiologists before autopsy, with "decision to proceed" based on the specialist perinatal pathologists' judgment and parental consent. Agreement rates between microfocus computed tomography and antenatal ultrasound were evaluated, and where feasible, diagnostic accuracy for microfocus computed tomography was calculated using autopsy as a reference standard. RESULTS: A total of 268 fetuses were included (2-350 grams body weight; 11-24 weeks' gestation), with cause for demise in 122 of 268 (45.5%). Of the 122 fetuses, 64 (52.5%) exhibited fetal anomalies. Although 221 of 268 (82.5%) fetuses had consent for invasive autopsy, only 29 of the 221 (13.1%) underwent this procedure, which implied an autopsy avoidance rate of 192 of 221 (86.9%). Complete agreement was present for all brain, thoracic, and abdominal pathologies, whereas sensitivity and specificity for cardiac anomalies were 66.7% and 91.7%, respectively. Microfocus computed tomography and antenatal ultrasound agreement was found in 219 of 266 cases (81.9%), with partial agreement in 21 of 266 (7.9%) and disagreement in 26 of 266 (10.5%), mostly because of additional cardiac, soft tissue, or genitourinary findings by microfocus computed tomography, which were not seen on the ultrasound. CONCLUSION: Fetal microfocus computed tomography imaging is a viable and useful tool for imaging early gestational fetuses and can avoid the need for invasive autopsy. Confirmation of antenatal diagnoses is achieved in most cases, and additional anomalies may also be detected.

来源:Am J Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Shelmerdine SC, Simcock IC, Hutchinson JC, et al. Postmortem microfocus computed tomography for noninvasive autopsies: experience in >250 human fetuses. Am J Obstet Gynecol. 2020. PMID: 32682860. doi:10.1016/j.ajog.2020.07.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。