早发型胎儿生长受限中胎盘灌注与氧饱和度的磁共振成像测量
在伦敦开展病例对照研究,12例无并发症妊娠与12例早发型胎儿生长受限(FGR)孕妇接受多室MRI检查,量化胎儿与母体血容量及胎儿-胎盘血氧饱和度。FGR组胎儿-胎盘氧饱和度低于对照组(56±16.2% vs 75±9.6%,P=0.02,95%CI 7.8-30.3%),异常程度与超声多普勒提示的疾病严重程度相关,正常妊娠中氧饱和度随扫描时孕龄变化。
要点
- 早发型FGR胎儿-胎盘氧饱和度低于无并发症妊娠(56±16.2% vs 75±9.6%,P=0.02)。
- 氧饱和度异常程度与超声多普勒定义的疾病严重程度相关。
- 正常妊娠中胎儿-胎盘氧饱和度估计与扫描时孕龄强相关(r=-0.83)。
核心结论
- 采用新型多模态MRI方案发现,合并早发型FGR的妊娠胎儿-胎盘血氧饱和度降低,异常程度与超声多普勒定义的疾病严重程度相关,正常妊娠亦存在氧饱和度的孕龄依赖性变化。
研究设计与样本
- 病例对照研究,在伦敦开展,纳入无并发症妊娠12例(估计胎儿体重[EFW]>第10百分位且母胎多普勒超声正常)与早发型FGR 12例(EFW<第3百分位,伴或不伴多普勒超声异常,<32周孕龄)。
- 所有孕妇接受MRI检查,采用多室MRI技术量化胎儿与母体血容量及胎儿-胎盘血氧饱和度。
主要发现
- FGR组平均孕龄27+5周(范围24+2至33+6周),对照组平均孕龄29+1周,FGR组EFW较对照组低705 g(95%CI -353至-1057 g)。
- MRI衍生的胎儿-胎盘氧饱和度对照组高于FGR组(75±9.6% vs 56±16.2%,P=0.02,95%CI 7.8-30.3%)。
- 对照组中胎儿-胎盘氧饱和度估计与扫描时孕龄强相关(r=-0.83)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: We hypothesised that a multi-compartment magnetic resonance imaging (MRI) technique that is sensitive to fetal blood oxygenation would identify changes in placental blood volume and fetal blood oxygenation in pregnancies complicated by early-onset fetal growth restriction (FGR). DESIGN: Case-control study. SETTING: London, UK. POPULATION: Women with uncomplicated pregnancies (estimated fetal weight [EFW] >10th centile for gestational age [GA] and normal maternal and fetal Doppler ultrasound, n = 12) or early-onset FGR (EFW <3rd centile with or without abnormal Doppler ultrasound <32 weeks GA, n = 12) were studied. METHODS: All women underwent MRI examination. Using a multi-compartment MRI technique, we quantified fetal and maternal blood volume and feto-placental blood oxygenation. MAIN OUTCOME MEASURES: Disease severity was stratified according to Doppler pulsatility index and the relationship to the MRI parameters was investigated, including the influence of GA at scan. RESULTS: The FGR group (mean GA 27+5 weeks, range 24+2 to 33+6 weeks) had a significantly lower EFW compared with the control group (mean GA 29+1 weeks; -705 g, 95% CI -353 to -1057 g). MRI-derived feto-placental oxygen saturation was higher in controls compared with FGR (75 ± 9.6% versus 56 ± 16.2%, P = 0.02, 95% CI 7.8-30.3%). Feto-placental oxygen saturation estimation correlated strongly with GA at scan in controls (r = -0.83). CONCLUSION: Using a novel multimodal MRI protocol we demonstrated reduced feto-placental blood oxygen saturation in pregnancies complicated by early-onset FGR. The degree of abnormality correlated with disease severity defined by ultrasound Doppler findings. Gestational age-dependent changes in oxygen saturation were also present in normal pregnancies. TWEETABLE ABSTRACT: MRI reveals differences in feto-placental oxygen saturation between normal and FGR pregnancy that is associated with disease severity.
引用
- Aughwane R, Mufti N, Flouri D, et al. Magnetic resonance imaging measurement of placental perfusion and oxygen saturation in early-onset fetal growth restriction. BJOG. 2020. PMID: 32603546. doi:10.1111/1471-0528.16387
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。