这项前瞻性队列研究纳入114例妊娠期高血压合并小于胎龄儿(HDP+SGA)、202例单纯妊娠期高血压(HDP-only)和401例对照孕妇,在孕26-41周用无创超声心输出量监测仪测量母体血流动力学。结果显示HDP+SGA组心率、心输出量更低而全身血管阻力更高,即使单纯HDP也存在血流动力学受损,提示母体心血管系统参与妊娠期高血压病理生理。

要点

  • HDP+SGA孕妇心率、心输出量低于单纯HDP和对照,全身血管阻力更高。
  • 单纯HDP孕妇血流动力学指标也较正常妊娠受损。
  • 两组HDP平均动脉压无显著差异,但血流动力学损害程度不同。

核心结论

  • 妊娠期高血压合并小于胎龄儿时母体血流动力学功能障碍比单纯妊娠期高血压更严重。
  • 即使单纯妊娠期高血压也存在血流动力学指标受损,支持母体心血管系统在妊娠期高血压中的作用。

研究设计与样本

  • 前瞻性队列研究,在英国三级医院开展。
  • 纳入114例HDP+SGA、202例单纯HDP和401例对照孕妇,孕周26-41周。
  • 使用无创超声心输出量监测仪(USCOM-1A®)测量母体血流动力学指标,并按设备参考范围校正孕周和母体特征。

主要发现

  • HDP+SGA组中位心率76 bpm,低于单纯HDP组85 bpm和对照组83 bpm。
  • HDP+SGA组心输出量0.85 MoM,低于单纯HDP组0.98 MoM和对照组0.97 MoM。
  • HDP+SGA组全身血管阻力1.4 MoM,高于单纯HDP组1.0 MoM和对照组1.2 MoM(以上均P<0.05)。
  • 两组HDP就诊时平均动脉压无显著差异(110 vs 107 mmHg,P=0.445)。

临床怎么用

  • 对妊娠期高血压孕妇应关注胎儿生长情况,合并SGA时提示更严重的母体血流动力学障碍。
  • 无创血流动力学监测可能有助于识别妊娠期高血压孕妇的心血管功能受损。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To describe maternal haemodynamic differences in gestational hypertension with small-for-gestational-age babies (HDP + SGA), gestational hypertension with appropriate-for-gestational-age babies (HDP-only) and control pregnancies. DESIGN: Prospective cohort study. SETTING: Tertiary Hospital, UK. POPULATION: Women with gestational hypertension and healthy pregnant women. METHODS: Maternal haemodynamic indices were measured using a non-invasive Ultrasound Cardiac Output Monitor (USCOM-1A® ) and corrected for gestational age and maternal characteristics using device-specific reference ranges. MAIN OUTCOME MEASURES: Maternal cardiac output, stroke volume, systemic vascular resistance. RESULTS: We included 114 HDP + SGA, 202 HDP-only and 401 control pregnancies at 26-41 weeks of gestation. There was no significant difference in the mean arterial blood pressure (110 versus 107 mmHg, P = 0.445) between the two HDP groups at presentation. Pregnancies complicated by HDP + SGA had significantly lower median heart rate (76 versus 85 bpm versus 83 bpm), lower cardiac output (0.85 versus 0.98 versus 0.97 MoM) and higher systemic vascular resistance (1.4 versus 1.0 versus 1.2 MoM) compared with control and HDP-only pregnancies, respectively (all P < 0.05). CONCLUSION: Women with HDP + SGA present with more severe haemodynamic dysfunction than HDP-only. Even HDP-only pregnancies exhibit impaired haemodynamic indices compared with normal pregnancies, supporting a role of the maternal cardiovascular system in gestational hypertension irrespective of fetal size. Central haemodynamic changes may play a role in the pathogenesis of pre-eclampsia and should be considered alongside placental aetiology. TWEETABLE ABSTRACT: Hypertensive disorders of pregnancy are associated with worse maternal haemodynamic function when associated with small-for-gestational-age birth.

来源:BJOG,查看原文。版权归原作者所有。