超声影像组学用于妊娠期糖尿病和/或子痫前期胎儿肺纹理分析
回顾性研究提取548例孕妇的548张胎儿肺超声图像中430个特征,构建机器学习模型区分妊娠期糖尿病(GDM)和/或子痫前期(PE)与正常妊娠的胎儿肺纹理,模型AUC达0.95-0.99,验证集敏感度78.8-97.1%、特异度79.8-94.3%。
要点
- 基于超声影像组学的胎儿肺纹理模型可区分GDM和/或PE与正常妊娠。
- 模型区分GDM/PE的AUC为0.95-0.99,验证集准确率81.0-95.3%。
- 该非侵入性技术有望用于预测GDM/PE孕妇新生儿呼吸并发症。
核心结论
- 基于超声影像组学技术,可区分GDM和/或PE妊娠与正常妊娠的胎儿肺纹理,也可区分不同孕周的胎儿肺。
- 研究支持进一步探索该非侵入性技术用于预测PE、GDM或其合并孕妇的新生儿呼吸并发症。
研究设计与样本
- 回顾性研究,纳入2018年7月至2019年8月在复旦大学附属妇产科医院分娩的548例孕妇的548张胎儿肺超声图像(四腔心切面,孕28-41周采集)。
- 每张图像提取430个高通量特征,数据随机分为训练集(80%图像)和独立测试集(20%图像),训练集中20%图像作为验证集。
- 使用标准机器学习模型基于胎儿肺纹理特征构建,并用回归模型评估肺纹理特征与GDM和/或PE及孕周的关系。
主要发现
- 548例中,单纯GDM 108例,单纯PE 71例,GDM合并PE 25例,正常344例。
- GDM和PE预测模型总体性能优于孕周预测模型,AUC为0.95-0.99。
- 验证集敏感度78.8-97.1%、特异度79.8-94.3%、准确率81.0-95.3%;独立测试集敏感度74.5-91.3%、特异度75.7-88.4%、准确率80.6-86.4%。
临床怎么用
- 该技术为无创手段,未来或可辅助识别GDM和/或PE孕妇胎儿肺纹理异常,以预警新生儿呼吸并发症风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To analyze and compare, using ultrasound-based radiomics technology, fetal-lung texture in pregnancies affected by gestational diabetes mellitus (GDM) and/or pre-eclampsia (PE) and in normal pregnancies, overall and at different gestational ages. METHODS: In this retrospective study, 430 high-throughput features per fetal-lung image were extracted from 548 fetal-lung ultrasound images (obtained at the level of the four-chamber view of the heart) in 548 pregnant women who delivered between July 2018 and August 2019 at the Obstetrics and Gynecology Hospital of Fudan University. Images had been obtained during ultrasound examinations between 28 and 41 weeks of gestation. The data were divided randomly into training set (80% of fetal-lung images) and independent test set (20% of images), and 20% of the images in the training set were then selected as the validation set. A standard machine-learning model based on ultrasound-based radiomics technology was created using features of fetal-lung texture extracted from the images, and a regression model was used to evaluate the relationship between lung-texture features, GDM and/or PE and gestational age. RESULTS: Of the 548 pregnancies included, 108 were affected by GDM alone, 71 by PE alone and 25 by both GDM and PE, and 344 were normal. The overall performance of the GDM and PE prediction model was superior to that of the gestational-age prediction model, with an area under the receiver-operating-characteristics curve of 0.95-0.99, sensitivity of 78.8-97.1% in the validation set and 74.5-91.3% in the independent test set, specificity of 79.8-94.3% in the validation set and 75.7-88.4% in the independent test set and accuracy of 81.0-95.3% in the validation set and 80.6-86.4% in the independent test set. CONCLUSIONS: Using ultrasound-based radiomics technology, fetal lungs from pregnancies grouped according to whether they were affected by GDM and/or PE could be distinguished from each other and from fetal lungs of normal pregnancies, and lungs from pregnancies at different gestational ages could be distinguished. These findings support further research to explore the use of this non-invasive technology to predict neonatal respiratory complications in women with PE, GDM or their combination. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Du Y, Fang Z, Jiao J, et al. Application of ultrasound-based radiomics technology in fetal-lung-texture analysis in pregnancies complicated by gestational diabetes and/or pre-eclampsia. Ultrasound Obstet Gynecol. 2021. PMID: 32250510. doi:10.1002/uog.22037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。