文献速递生殖医学妇科

虚拟超声宫腔镜与传统宫腔镜在不孕症评估中的比较

Comparison of Virtual Ultrasonographic Hysteroscopy with Conventional Hysteroscopy in the Workup of Patients Who Are Infertile.
PubMed 文献 · J Minim Invasive Gynecol · 2020-03-19

本研究为单中心回顾性队列研究,纳入120例不孕症女性,比较虚拟超声宫腔镜(VUH)与传统诊断性宫腔镜的耐受性和诊断准确性。结果显示VUH对子宫内膜病变的敏感性和特异性均为100%,对宫腔病变和子宫畸形的敏感性分别为80%和100%,特异性均为100%,且大多数患者耐受良好。

要点

  • VUH对子宫内膜病变诊断的敏感性和特异性均达100%。
  • VUH对子宫畸形诊断敏感性100%,对宫腔病变敏感性80%。
  • 67%患者认为检查比预期疼痛轻,无严重并发症。

核心结论

  • VUH耐受良好,与传统宫腔镜相比在宫腔评估中显示出高准确率(100%)。

研究设计与样本

  • 单中心回顾性队列研究,纳入120例连续不孕症女性,均接受子宫输卵管超声造影及后续VUH和传统宫腔镜。

主要发现

  • VUH诊断子宫内膜病变的敏感性和特异性均为100%(95%CI分别为84.6%-100%和96.3%-100%)。
  • VUH诊断宫腔病变的敏感性为80%(95%CI 28.4%-99.5%),特异性为100%(95%CI 96.8%-100%)。
  • VUH诊断子宫畸形的敏感性和特异性均为100%(95%CI分别为75.3%-100%和96.6%-100%)。
  • 子宫内膜病变、宫腔改变和子宫畸形的阳性预测值分别为100%(95%CI 84.6%-100%)、100%(95%CI 39.8%-100%)和100%(95%CI 75.3%-100%)。
  • ROC曲线下面积分别为100%、90%(95%CI 70%-100%)和100%。

关键数值与推荐

  • 纳入标准为不孕至少1年,评估在月经周期早至中期卵泡期进行。
  • VUH findings与随后一个月内进行的传统宫腔镜结果进行比较。

临床怎么用

  • VUH可作为不孕症患者宫腔评估的耐受性良好且准确的方法。

局限性

  • 回顾性设计,单中心,样本量有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY OBJECTIVE: To compare the tolerability and diagnostic accuracy of virtual ultrasonographic hysteroscopy (VUH) with that of conventional diagnostic outpatient hysteroscopy in the workup of patients who are infertile. DESIGN: A single-center, retrospective cohort study. SETTING: Department of Obstetrics and Gynecology, Gynecologic Oncology, and Minimally Invasive Pelvic Surgery Unit of Sacred Heart Hospital Don Calabria in Negrar, Italy. PATIENTS: A total of 120 consecutive women who underwent hysterosalpingosonography and subsequent VUH and conventional hysteroscopy for infertility evaluation were included. The inclusion criterion was infertility for at least 1 year, with evaluation in the early or intermediate follicular phase of the menstrual cycle. INTERVENTIONS: After the placement of an intracervical catheter, a Ringer Lactate solution was injected into the uterine cavity and fallopian tubes, and a 3D volume was obtained. The ultrasound volume acquired was successively elaborated offline, and a VUH was performed. Subsequently, a variable amount of air was introduced into the uterine cavity, and the patency of the salpinges was evaluated. MEASUREMENTS AND MAIN RESULTS: The VUH findings were compared with those of conventional hysteroscopy performed in the subsequent month. For the detection of endometrial pathology in the overall pool, the sensitivity and specificity of VUH in comparison with conventional hysteroscopy were 100% (95% confidence interval [CI], 84.6%-100%) and 100% (95% CI, 96.3%-100%), respectively. For the detection of uterine cavity pathology and uterine malformations in the overall pool, the sensitivities of VUH were 80% (95% CI, 28.4%-99.5%) and 100% (95% CI, 75.3%-100%), respectively, with specificities of 100% (95% CI, 96.8%-100%) and 100% (95% CI, 96.6%-100%), respectively, when compared with conventional hysteroscopy. The positive predictive values for endometrial pathology, uterine cavity alterations, and uterine malformations were 100% (95% CI, 84.6%-100%), 100% (95% CI, 39.8%-100%), and 100% (95% CI, 75.3%-100%), respectively, with a receiver operating characteristic area of 100%, 90% (95% CI, 70%-100%), and 100%, respectively. There were no cases of severe vasovagal reactions or other complications. Most patients (67%, 81 of 120 women) described the examination as "less painful than expected," 25% (30 of 120 women) "just as expected," and only 7% (9 of 120 women) as "more painful than expected." CONCLUSION: VUH was well tolerated and showed a high accuracy (100%) in the study of the uterine cavity when compared with conventional hysteroscopy.

来源:J Minim Invasive Gynecol,查看原文。版权归原作者所有。

引用

  1. Stepniewska AK, Verrazzo P, Savelli L, et al. Comparison of Virtual Ultrasonographic Hysteroscopy with Conventional Hysteroscopy in the Workup of Patients Who Are Infertile. J Minim Invasive Gynecol. 2020. PMID: 32197993. doi:10.1016/j.jmig.2020.03.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。