文献速递母胎医学产科

斑点追踪分析胎儿心脏可提高产前主动脉缩窄检出率

Improved detection of coarctation of the aorta using speckle-tracking analysis of fetal heart on last examination prior to delivery.
PubMed 文献 · Ultrasound Obstet Gynecol · 2021-01-01

本研究回顾性分析108例产前疑诊主动脉缩窄(CoA)胎儿末次超声四腔心切面,采用斑点追踪测量心外膜及左右心室大小、形态与收缩功能,并以200例正常胎儿计算Z值。产后确诊54例真性CoA与54例假阳性,逻辑回归筛选的28个变量可正确识别96%(52/54)真性CoA,假阳性率4%、假阴性率4%,ROC曲线下面积0.98(SE 0.023;95%CI 0.84-1)。

要点

  • 传统标准疑诊CoA的假阳性率超50%,真性检出率不足50%。
  • 斑点追踪多参数模型识别真性CoA的灵敏度达96%,假阳性率仅4%。
  • 真性CoA组合并心脏畸形比例(93%)显著高于假阳性组(61%)。

核心结论

  • 对产前疑诊CoA胎儿,基于斑点追踪的多项心室测量有助于优化诊断、降低假阳性。

研究设计与样本

  • 回顾性分析108例产前经儿科心脏病医生按传统标准疑诊CoA胎儿的末次产前四腔心DICOM图像。
  • 产后区分真性CoA(需手术)与假阳性CoA,并以200例正常胎儿计算各测量Z值。
  • 采用逻辑回归筛选区分真性CoA与假阳性CoA的变量。

主要发现

  • 108例中54例产后确诊真性CoA,54例为假阳性CoA。
  • 右/左面积失调>90百分位在真性CoA组占80%(43例),假阳性组占76%(41例)。
  • 真性CoA组合并心脏畸形93%(50例)高于假阳性组61%(33例),P<0.001。
  • 常见合并畸形:二叶主动脉瓣真性CoA 46%(25例)vs假阳性22%(12例),P<0.01;主动脉弓发育不良31%(17例)vs 11%(6例),P<0.01;室间隔缺损33%(18例)vs 11%(6例),P<0.05;二尖瓣异常30%(16例)vs 4%(2例),P<0.01。
  • 逻辑回归28个变量正确识别96%(52/54)真性CoA,假阳性率4%(2/54),假阴性率4%(2/54),ROC曲线下面积0.98(SE 0.023;95%CI 0.84-1)。

关键数值与推荐

  • 右/左面积失调>90百分位在两组间无显著差异。
  • 区分变量包括四腔心心外膜大小、左右心室大小与形态、左右心室收缩功能异常。

临床怎么用

  • 对产前疑诊CoA胎儿,可在末次产前超声中加用斑点追踪测量心外膜及左右心室多参数。
  • 结合合并心脏畸形(如二叶主动脉瓣、主动脉弓发育不良、室间隔缺损、二尖瓣异常)提高真性CoA辨识。

局限性

  • 回顾性设计,样本来自单一系列,结论需前瞻性验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The false-positive rate for prenatal diagnosis of coarctation of the aorta (FP-CoA) commonly exceeds 50%, with an accurate detection rate of < 50%. This study was conducted to determine if the sensitivity for prenatal detection of true CoA and the FP-CoA rate could be improved by evaluating the fetal epicardial size and shape in the four-chamber view (4CV) and the endocardial right (RV) and left (LV) ventricular size, shape and contractility. METHODS: We analyzed retrospectively Digital Imaging and Communications in Medicine (DICOM) clips of the 4CV from the last examination prior to delivery in a series of 108 fetuses with CoA suspected prenatally by pediatric cardiologists using traditional diagnostic criteria. Postnatal evaluation distinguished those fetuses which subsequently required CoA surgery (true positives; true CoA) from those that were FP-CoA. Postnatal cardiac abnormalities were identified for each group. For the prenatal evaluation, we measured the 4CV end-diastolic epicardial area, circumference, length, width and global sphericity index. Speckle-tracking analysis was used to compute the endocardial RV and LV end-diastolic area, length, 24-segment sphericity index, 24-segment transverse width and the following functional parameters: fractional area change; global longitudinal, free-wall and septal-wall strain; basal-apical-length, basal free-wall and basal septal-wall fractional shortening; septal-wall annular plane systolic excursion; 24-segment transverse-width fractional shortening; and LV end-diastolic and end-systolic volumes, stroke volume, cardiac output and ejection fraction. In addition, the RV/LV end-diastolic area ratio was computed. Using a control group of 200 normal fetuses, the mean and SD for each of the above cardiac measurements was used to compute the Z-scores for each measurement in each of the 108 study fetuses. Logistic regression analysis was then performed on the Z-score values to identify variables that separated the true CoA group from the FP-CoA group. RESULTS: Of the 108 study fetuses, 54 were confirmed postnatally to have true CoA and 54 were FP-CoA. Right/left area disproportion > 90th centile was present in 80% (n = 43) of the true-CoA fetuses and 76% (n = 41) of the FP-CoA fetuses. Fetuses with true CoA had a significantly greater number of associated cardiac abnormalities (93%, n = 50) compared with the FP-CoA fetuses (61%, n = 33) (P < 0.001). The most common associated malformations were bicuspid aortic valve (true CoA, 46% (n = 25) vs FP-CoA, 22% (n = 12); P < 0.01), aortic arch hypoplasia (true CoA, 31% (n = 17) vs FP-CoA, 11% (n = 6); P < 0.01), ventricular septal defect (true CoA, 33% (n = 18) vs FP-CoA, 11% (n = 6); P < 0.05) and mitral valve abnormality (true CoA, 30% (n = 16) vs FP-CoA, 4% (n = 2); P < 0.01). Logistic regression analysis identified 28 variables that correctly identified 96% (52/54) of the fetuses with true CoA, with a false-positive rate of 4% (2/54) and a false-negative rate of 4% (2/54). These variables included the epicardial size in the 4CV, size and shape of RV and LV, and abnormal contractility of RV and LV. The area under the receiver-operating-characteristics curve was 0.98 (SE, 0.023; 95% CI, 0.84-1). There was no significant difference in the percent of fetuses with RV/LV area disproportion between those with CoA and those that were FP-CoA. CONCLUSIONS: Speckle-tracking analysis of multiple ventricular measurements may be helpful to refine the diagnosis in fetuses that are suspected to have CoA prenatally. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. DeVore GR, Haxel C, Satou G, et al. Improved detection of coarctation of the aorta using speckle-tracking analysis of fetal heart on last examination prior to delivery. Ultrasound Obstet Gynecol. 2021. PMID: 32022339. doi:10.1002/uog.21989

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。