文献速递妇科

经阴道超声准确测量直肠乙状结肠深部子宫内膜异位症病灶至肛缘距离

Transvaginal sonography accurately measures lesion-to-anal-verge distance in women with deep endometriosis of the rectosigmoid.
PubMed 文献 · Ultrasound Obstet Gynecol · 2020-01-01

这项前瞻性多中心观察性研究纳入147例有症状的直肠乙状结肠深部子宫内膜异位症女性,比较经阴道超声(TVS)与术中测量(IOM)病灶至肛缘距离(LAVD)的一致性。结果显示TVS与IOM测量值无显著差异,ICC为0.81,提示TVS可用于术前评估吻合口高度。

要点

  • TVS测量LAVD与术中测量高度一致,ICC为0.81。
  • TVS与吻合口高度的一致性中等,ICC为0.78。
  • TVS有助于预估全层切除后的吻合口高度,优化术前咨询。

核心结论

  • TVS测量的LAVD与术中测量在直肠乙状结肠深部子宫内膜异位症女性中具有良好一致性。

研究设计与样本

  • 前瞻性观察性多中心研究,纳入2017年4月至2019年9月期间计划手术的有症状直肠乙状结肠深部子宫内膜异位症女性,最终分析147例中的部分患者。

主要发现

  • TVS平均LAVD为114.8±36.5 mm,术中测量平均值为116.9±42.3 mm,平均差异-2.12 mm(95%CI -6.33至2.05 mm),P=0.32。
  • Bland-Altman分析显示两种方法一致性良好,ICC为0.81(95%CI 0.74-0.86),Spearman相关系数为0.68(95%CI 0.56-0.77)。
  • TVS测量的LAVD与吻合口高度的平均差异为10.25 mm(95%CI 5.94-14.32 mm),P=0.0005,ICC为0.78(95%CI 0.66-0.85)。

临床怎么用

  • TVS可用于术前评估直肠乙状结肠深部子宫内膜异位症病灶至肛缘距离,辅助预估吻合口高度。
  • 该信息有助于降低并发症和临时造口风险,并改善患者咨询。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: First, to investigate the accuracy of transvaginal sonography (TVS) for presurgical evaluation of the distance between the most caudal part of the endometriotic lesion and the anal verge (lesion-to-anal-verge distance (LAVD)) in women with rectosigmoid deep endometriosis (DE), compared with intraoperative measurement (IOM). Second, to assess the agreement between anastomosis height and LAVD measured using TVS. METHODS: This was a prospective observational multicenter study of symptomatic women who were scheduled for surgical treatment of rectosigmoid DE, by either discoid or segmental resection, between April 2017 and September 2019. Presurgical TVS was performed to evaluate the LAVD in two ways, depending on the level of the lesion. Method 1: for lesions at the level of the rectovaginal septum (RVS), the caudal part of the lesion was identified on TVS and an index finger was placed on the TVS probe at the level of the anal verge. The probe was withdrawn and the distance from the tip of the TVS probe down to the index finger was measured using a ruler, representing the LAVD. Method 2: for lesions above the RVS, the distance between the caudal part of the lesion and the lower lip of the posterior cervix was measured in a frozen image (LAVD-1), and the distance between the lower lip of the posterior cervix and the anal verge (LAVD-2) was measured using Method 1. These two measurements (LAVD-1 and LAVD-2) were added together and the result represented the total LAVD. During surgery, a rectal probe was used to perform IOM of LAVD, which was considered as the gold standard test. Agreement between LAVD measured using TVS and the IOM was assessed using Bland-Altman analysis. The intraclass correlation coefficient (ICC) for absolute agreement and Spearman's correlation coefficient were also calculated. Systematic and proportional bias were tested for significance using the paired t-test. Similar analysis was performed to assess agreement between LAVD measured using TVS and anastomosis height. RESULTS: A total of 147 consecutive women were considered eligible for inclusion. Fourteen women were excluded initially. Thirty-four discoid resections and 102 segmental resections were performed; both procedures were performed in three women. Two more women were excluded from the final analysis because the measurements represented extreme outliers. The mean LAVD measured using TVS was 114.8 ± 36.5 mm and the mean IOM was 116.9 ± 42.3 mm. There was no statistically significant difference between LAVD measured using TVS and IOM (mean difference, -2.12 mm (95% CI, -6.33 to 2.05 mm); P = 0.32). Bland-Altman analysis showed that there was good agreement between the two methods. The ICC was 0.81 (95% CI, 0.74-0.86) and Spearman's correlation coefficient was 0.68 (95% CI, 0.56-0.77). The mean difference between LAVD measured using TVS and anastomosis height was statistically, but not clinically, significant (mean difference, 10.25 mm (95% CI, 5.94-14.32 mm); P = 0.0005), and the ICC was 0.78 (95% CI, 0.66-0.85). CONCLUSIONS: There is good agreement between the LAVD measured using TVS and the IOM in women with rectosigmoid DE. As a consequence, TVS could be useful for estimation of the height of the final surgical anastomosis in women undergoing full-thickness resection for rectosigmoid DE. This is of pivotal importance in reducing the risk of complications and need for a temporary stoma, and could improve patient counseling. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Aas-Eng MK, Dauser B, Lieng M, et al. Transvaginal sonography accurately measures lesion-to-anal-verge distance in women with deep endometriosis of the rectosigmoid. Ultrasound Obstet Gynecol. 2020. PMID: 32068921. doi:10.1002/uog.21995

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。