绝经后出血妇女子宫内膜癌的超声检测:系统综述与荟萃分析
该系统综述与荟萃分析纳入44项队列研究、17,339例绝经后出血妇女(其中子宫内膜癌1341例,占7.7%),评估子宫内膜厚度(ET)截断值及子宫内膜体积(EV)、血流指数等超声指标对子宫内膜癌的检测效能;结果显示ET≥5 mm在保持较高敏感性的同时改善特异性,可减少17%的侵入性检查。
要点
- 绝经后出血妇女子宫内膜癌患病率为7.7%(1341/17339)。
- 合并子宫内膜癌者平均ET为16.4 mm(95%CI 14.8-18.1),无癌者为4.1 mm。
- ET≥5 mm较≥3或4 mm敏感性相近(96.2%,95%CI 92.3-98.1)且特异性更优(51.5%,95%CI 42.3-60.7)。
核心结论
- 绝经后出血妇女中,子宫内膜癌患者平均ET显著高于无癌者。
- ET≥5 mm在诊断子宫内膜癌时在敏感性与特异性之间呈现可接受的权衡。
研究设计与样本
- 系统综述与荟萃分析,检索Clinicaltrials.gov及MEDLINE(PubMed)1990年1月至2016年3月发表的文献。
- 纳入44项同行评议的原始队列研究,共17,339例绝经后出血妇女,其中子宫内膜癌1341例(7.7%)。
主要发现
- 合并子宫内膜癌的绝经后出血妇女(n=417)汇总平均ET为16.4 mm(95%CI 14.8-18.1 mm)。
- 无子宫内膜癌的绝经后出血妇女汇总平均ET为4.1 mm。
- 31项研究报告了3至20 mm不同ET截断值的结局。
- 与≥3或4 mm相比,ET≥5 mm敏感性相近(96.2%,95%CI 92.3-98.1),特异性更优(51.5%,95%CI 42.3-60.7),可使侵入性检查率降低17%。
- EV、VI、VFI和FI与子宫内膜癌显著相关,但因数据有限未分析特定截断值的效能。
关键数值与推荐
- ET≥5 mm诊断子宫内膜癌的敏感性为96.2%(95%CI 92.3-98.1),特异性为51.5%(95%CI 42.3-60.7)。
- 采用ET≥5 mm较≥3或4 mm可减少17%的侵入性检查。
临床怎么用
- 对绝经后出血妇女,可考虑以ET≥5 mm作为提示子宫内膜癌的超声截断值。
- 该截断值有助于在保持高敏感性的同时减少不必要的侵入性检查。
局限性
- EV、VI、VFI和FI因数据有限未能分析特定截断值的诊断效能。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To assess the performance of endometrial thickness (ET) cut-offs for detecting endometrial cancer (EC) in women with postmenopausal bleeding (PMB) and evaluate the clinical utility of additional ultrasound measures such as endometrial volume (EV), vascular flow index (VFI), vascularization index (VI), and uterine artery flow index (FI). METHODS: Clinicaltrials.gov and MEDLINE database via PubMed were queried for studies published between 1/1990 and 3/2016 using specific MeSH terms. Original, peer-reviewed cohort studies reporting EC outcomes and specific ultrasound findings by PMB status were included. RESULTS: Study design, country, clinical setting inclusion/exclusion criteria, aggregate study-level demographic and clinical data were extracted from 44 studies including 17,339 women with PMB and 1341 cases of EC (7.7%). In women with PMB and EC (n = 417), pooled mean ET was 16.4 mm (95% CI, 14.8-18.1 mm). In women with PMB without EC, pooled mean ET was 4.1 mm. 31 studies reported outcomes using different ET cut-off values ranging from 3 to 20 mm. Compared to ≥3 or 4 mm, a cutoff of ≥5 mm had similar sensitivity (96.2, 95%CI 92.3, 98.1) with improved specificity for EC (51.5, 95%CI 42.3-60.7), allowing to reduce the rate of invasive workup for PMB by 17%. EV, VI, VFI, and FI were significantly correlated with EC, but performance of specific cut-offs was not analyzed due to limited data. CONCLUSION: Among women with PMB mean ET is substantially higher in women with EC compared to those without EC. An ET cutoff of ≥5 mm shows an acceptable tradeoff between sensitivity and specificity for diagnosis of EC.
引用
- Long B, Clarke MA, Morillo ADM, et al. Ultrasound detection of endometrial cancer in women with postmenopausal bleeding: Systematic review and meta-analysis. Gynecol Oncol. 2020. PMID: 32008795. doi:10.1016/j.ygyno.2020.01.032
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。