产前前瞻性测量流出道对主动脉缩窄预测的影响
本研究评估产前疑似主动脉缩窄(CoA)胎儿前瞻性获取的流出道测量指标。149例中51.7%出生后确诊CoA,确诊者远端横主动脉弓(DTAA)直径Z评分及孕中期DTAA/动脉导管(AD)比值Z评分均小于假阳性病例。DTAA和AD直径Z评分是出生后CoA的唯一显著预测因子,假阳性病例中二叶式主动脉瓣发生率为30%。
要点
- 产前疑似CoA胎儿中,出生后确诊者DTAA直径Z评分低于假阳性者(-2.8 vs -1.9,P=0.039)。
- 孕中期DTAA/AD比值Z评分在确诊者中也低于假阳性者(-3.13 vs -2.61,P=0.005)。
- DTAA和AD直径Z评分是出生后CoA的唯一显著预测因子(P=0.001)。
核心结论
- 在选择的产前疑似CoA队列中,DTAA和AD直径Z评分可用于评估出生后CoA风险。
- 假阳性病例中二叶式主动脉瓣高发,其病因及长期意义需进一步研究。
研究设计与样本
- 研究期间对疑似CoA胎儿常规测量主动脉瓣、肺动脉瓣、DTAA和AD直径。
- Z评分基于本单位超过7000例胎儿已发表的参考范围计算。
主要发现
- 149例产前疑似CoA中,77例(51.7%)出生后6个月内确诊CoA。
- 确诊CoA胎儿DTAA直径Z评分小于假阳性病例(-2.8 vs -1.9,P=0.039)。
- 确诊CoA胎儿孕中期DTAA/AD直径比值Z评分小于假阳性病例(-3.13 vs -2.61,P=0.005)。
- 多因素回归分析显示DTAA和AD直径Z评分是出生后CoA的唯一显著预测因子(P=0.001)。
- 假阳性病例中二叶式主动脉瓣发生率为30%。
临床怎么用
- 对产前疑似CoA胎儿,可前瞻性测量DTAA和AD直径并计算Z评分以辅助风险分层。
- 假阳性病例中二叶式主动脉瓣发生率高,提示出生后需关注主动脉瓣形态。
局限性
- 研究为单中心回顾性队列,样本来自特定三级中心,结果外推需谨慎。
- 仅纳入出生后随访至少6个月的病例,可能存在选择偏倚。
- 原文未报告前瞻性测量与回顾性测量的直接比较数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Prenatal diagnosis of coarctation of the aorta (CoA) is associated with reduced mortality and morbidity, however, accurate prenatal prediction remains challenging. To date, studies have used retrospective measurements of the outflow tracts to evaluate their potential to predict CoA. Our primary objective was to evaluate prospectively acquired measurements of the outflow tracts in fetuses with prenatally suspected CoA. A secondary aim was to report the postnatal prevalence of bicuspid aortic valve in this cohort. METHODS: Pregnancies with suspicion of isolated CoA and with a minimum of 6 months' postnatal follow-up available were identified from the cardiac database of a tertiary fetal cardiology center in the UK, between January 2002 and December 2017. Measurement of the aortic valve, pulmonary valve, distal transverse aortic arch (DTAA) and arterial duct (AD) diameters were undertaken routinely in fetuses with suspected CoA during the study period. Z-scores were computed using published reference ranges based on > 7000 fetuses from our own unit. RESULTS: Of 149 pregnancies with prenatally suspected CoA included in the study, CoA was confirmed within 6 months after birth in 77/149 (51.7%) cases. DTAA diameter Z-score and the Z-score of second-trimester DTAA/AD diameter ratio were smaller in fetuses with postnatally confirmed CoA than those in false-positive cases (-2.8 vs -1.9; P = 0.039 and -3.13 vs -2.61; P = 0.005, respectively). Multiple regression analysis demonstrated that the Z-scores of DTAA and AD diameters were the only significant predictors of postnatal CoA (P = 0.001). Bicuspid aortic valve was identified in 30% of the false-positive cases. CONCLUSIONS: Measurement of DTAA and AD diameter Z-scores can be used to ascertain risk for postnatal CoA in a selected cohort. The high incidence of bicuspid aortic valve in false-positive cases merits further study with respect to both etiology and longer-term significance. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
引用
- Vigneswaran TV, Zidere V, Chivers S, et al. Impact of prospective measurement of outflow tracts in prediction of coarctation of the aorta. Ultrasound Obstet Gynecol. 2020. PMID: 31875324. doi:10.1002/uog.21957
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。