电阻测量实时确认小鼠和人卵母细胞穿透与存活
本研究探讨电阻增加能否确认卵母细胞穿透与存活。实验用小鼠及人卵母细胞,测量ICSI针推进前后电阻变化。结果示穿透或卵膜完整者电阻显著增加,提示电阻测量可作为不依赖光学可视化的客观确认工具。
要点
- 卵膜穿透伴随电阻显著增加,可用于客观确认穿透。
- 卵膜完整卵母细胞的电阻增加显著高于碎片化卵母细胞。
- 该技术经进一步验证和安全评估后可能整合入手动和机器人ICSI系统。
核心结论
- 电阻增加可作为确认卵母细胞穿透和存活的可靠工具,不依赖光学可视化。
研究设计与样本
- 实验研究,在学术中心研究实验室进行,使用6至12周龄雌鼠卵母细胞及女性取卵获得的未成熟卵母细胞。
主要发现
- 步骤1:穿透的小鼠卵母细胞电阻变化中位数7.79 MΩ(范围2.57-106.00),未穿透者0.10 MΩ(范围-0.06-0.69),差异有统计学意义。
- 步骤2:卵膜视觉完整的小鼠卵母细胞电阻变化中位数6.5 MΩ(范围0.1-191.7),碎片化者0.1 MΩ(范围-0.3-2.2),差异有统计学意义。
- 步骤3:卵膜视觉完整的人卵母细胞电阻变化中位数1.92 MΩ(范围-0.05-6.70),碎片化者0.11 MΩ(范围0.00-0.30),差异有统计学意义。
临床怎么用
- 该电阻测量方法经进一步验证和安全评估后,可能整合入手动和机器人ICSI系统以确认卵母细胞穿透和存活。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate if oocyte penetration and viability can be confirmed by an electrical resistance increase. Automated (robotic) intracytoplasmic sperm injection (ICSI) requires confirmation of oolemma penetration before sperm injection. Visual assessment using image processing algorithms have been developed but remain unreliable. We hypothesized that an increase in electrical resistance upon oolemma piercing during ICSI can serve as an objective tool to confirm oocyte penetration and viability. DESIGN: Experimental study. SETTING: Research laboratory in an academic center. PATIENTS/ANIMALS: Oocytes from female mice and women undergoing oocyte retrieval procedure. INTERVENTION: Oolemma piercing attempts with the ICSI pipette were performed by advancing the pipette towards mature (metaphase II) oocytes collected from 6 to 12-week-old mice and immature (germinal vesicle stage and metaphase I) oocytes donated by women who underwent oocyte retrieval. Electrical resistance was measured using a conventional electrophysiological setup that includes an electrical resistance meter and two electrical wires located in the lumina of the holding and ICSI pipettes. MAIN OUTCOME MEASURE(S): The measure of interest was the change in electrical resistance (ΔR) before and after advancing the ICSI pipette in an attempt to penetrate an oocyte. The experiments of resistance measurements were done in 3 steps: Step 1 (proof of concept), penetrated vs. non-penetrated mouse oocytes. Step 2, mouse oocytes with visually intact oolemma vs. fragmented mouse oocytes. Step 3, human oocytes with visually intact oolemma vs. fragmented human oocytes. For each group, median and range (in parenthesis) of ΔR were determined in MΩ. Mann-Whitney test was performed to compare the two groups in each step. RESULTS: In Step 1, the penetrated mouse oocytes showed a statistically significant resistance increase compared to the non-penetrated ones (n = 20, median ΔR = 7.79 [2.57 - 106.00] vs. n = 15, median ΔR = 0.10 [-0.06 - 0.69], respectively. In Step 2, the mouse oocytes with visually intact oolemma showed a statistically significant resistance increase compared to the fragmented ones (n = 45, median ΔR = 6.5 [0.1 - 191.7] vs. n = 13, median ΔR = 0.1 [-0.3 - 2.2], respectively. In Step 3, the human oocytes with visually intact oolemma showed a statistically significant resistance increase compared to the fragmented ones (n = 96, median ΔR = 1.92 [-0.05 - 6.70] vs. n = 17, median ΔR = 0.11 [0.00 - 0.30], respectively. CONCLUSIONS: An electrical resistance increase can serve as a reliable tool to confirm oocyte penetration and viability, independent of optical visualization. Following further validation and safety assessment, this technology can potentially be integrated into manual and robotic ICSI systems.
引用
- Mor A, Zhang M, Esencan E, et al. A step towards the automation of intracytoplasmic sperm injection: real time confirmation of mouse and human oocyte penetration and viability by electrical resistance measurement. Fertil Steril. 2019. PMID: 31883732. doi:10.1016/j.fertnstert.2019.09.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。