机器人辅助结肠造口还纳术在腹壁疝与粘连患者中的应用
本文报道一例64岁子宫内膜癌患者,既往因憩室炎行乙状结肠切除及降结肠造口,现要求还纳。患者合并大型腹壁疝与造口旁疝,行机器人辅助结肠造口还纳及降结肠-直肠端侧吻合,术中因直肠穿孔牺牲部分直肠并加做保护性回肠造口,术后恢复顺利,3个月造影无吻合口漏或狭窄。
要点
- 机器人辅助结肠造口还纳在妇科肿瘤患者中可行,前提是无复发证据。
- 术中需广泛肠粘连松解和脾曲游离以保证吻合口无张力。
- 低位结直肠吻合需考虑保护性回肠造口。
核心结论
- 机器人辅助结肠造口还纳及降结肠-直肠吻合成功完成。
- 微创技术对于无复发的妇科肿瘤造口患者是开腹手术的可行替代方案。
研究设计与样本
- 病例报告及机器人辅助结肠造口还纳与端侧吻合的逐步视频演示。
- 地点为康涅狄格州纽黑文的三级转诊中心,患者为64岁女性。
主要发现
- 肠粘连松解耗时约2小时,需游离脾曲以提供足够近端肠段。
- 28-mm EEA尺寸测量器在狭窄远端 caudal 的直肠处穿孔,被迫牺牲较长远端直肠,以3-0倒刺线双层缝合后剩余约6-8 cm远端直肠。
- 行降结肠-远端直肠端侧吻合,气泡试验确认吻合完整性,因吻合口较低行保护性袢式回肠造口。
- 术后病程平稳,还纳后3个月泛影葡胺灌肠未见吻合口漏或狭窄,回肠造口还纳无并发症。
临床怎么用
- 对于无复发的妇科肿瘤造口患者,可考虑机器人辅助微创造口还纳术。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY OBJECTIVE: To demonstrate a surgical video wherein a robot-assisted colostomy takedown was performed with anastomosis of the descending colon to the rectum after reduction of ventral hernias and extensive lysis of adhesions. DESIGN: Case report and a step-by-step video demonstration of a robot-assisted colostomy takedown and end-to-side anastomosis. SETTING: Tertiary referral center in New Haven, Connecticut. A 64-year-old female was diagnosed with stage IIIA endometrioid endometrial adenocarcinoma in 2015 when she underwent an optimal cytoreductive surgery. In addition, she required resection of the sigmoid colon and a descending end colostomy with Hartmann's pouch, mainly secondary to extensive diverticulitis. After adjuvant chemoradiation, she remained disease free and desired colostomy reversal. Body mass index at the time was 32 kg/m2. Computed tomography of her abdomen and pelvis did not show any evidence of recurrence but was notable for a large ventral hernia and a parastomal hernia. She then underwent a colonoscopy, which was negative for any pathologic condition, except for some narrowing of the distal rectum above the level of the levator ani. INTERVENTIONS: Enterolysis was extensive and took approximately 2 hours. The splenic flexure of the colon had to be mobilized to provide an adequate proximal limb to the anastomosis site. An anvil was then introduced into the distal descending colon through the colostomy site. A robotic stapler was used to seal the colostomy site and detach it from the anterior abdominal wall. Unfortunately, the 28-mm EEA sizer (Covidien, Dublin, Ireland) perforated through the distal rectum, caudal to the stricture site. A substantial length of the distal rectum had to be sacrificed secondary to the perforation, which mandated further mobilization of the splenic flexure. The rectum was then reapproximated with a 3-0 barbed suture in 2 layers. This provided us with approximately 6- to 8-cm distal rectum. An end-to-side anastomosis of the descending colon to the distal rectum was performed. Anastomotic integrity was confirmed using the bubble test. Because of the lower colorectal anastomosis, a protective diverting loop ileostomy was performed. The patient had an uneventful postoperative course. A hypaque enema performed 3 months after the colostomy takedown showed no evidence of anastomotic leak or stricture. The ileostomy was then reversed without any complications. CONCLUSION: Robot-assisted colostomy takedown and anastomosis of the descending colon to rectum were successfully performed. Although there is a paucity of literature examining this technique within gynecologic surgery, the literature on general surgery has supported laparoscopic Hartmann's reversal and has demonstrated improved rates of postoperative complications and incisional hernia and reduced duration of hospitalization [1]. Minimally invasive technique is a feasible alternative to laparotomy for gynecologic oncology patients who undergo colostomy, as long as the patients are recurrence free.
引用
- Mutlu L, Kim S, Altwerger G, et al. Robotic Colostomy Takedown in a Patient with Extensive Ventral Hernias and Adhesive Disease. J Minim Invasive Gynecol. 2019. PMID: 31838277. doi:10.1016/j.jmig.2019.12.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。