文献速递产科母胎医学

胎儿生物测量误差对小于胎龄儿和大于胎龄儿识别的影响

Impact of biometric measurement error on identification of small- and large-for-gestational-age fetuses.
PubMed 文献 · Ultrasound Obstet Gynecol · 2020-01-08

该研究基于既往标准化测量方案获得的胎儿腹围、头围和股骨长测量误差标准差,通过蒙特卡洛模拟分析测量误差对超声估计胎儿体重分类的影响。结果显示测量误差可导致估计胎儿体重显著偏差,造成小于胎龄儿和大于胎龄儿的误分类;使用第10和第90百分位筛查时检出率为78.0%、假阳性率4.7%,放宽至第30和第70百分位时检出率升至98.2%、假阳性率升至24.2%。

要点

  • 胎儿腹围、头围和股骨长的测量误差标准差分别为6.93 mm、5.15 mm和1.38 mm。
  • 使用第10和第90百分位筛查小于和大于胎龄儿时,检出率78.0%,假阳性率4.7%。
  • 放宽 cut-off 至第30和第70百分位,检出率升至98.2%,假阳性率升至24.2%。

核心结论

  • 胎儿生物测量误差导致估计胎儿体重产生显著误差,造成小于胎龄儿和大于胎龄儿的误分类。
  • 通过有效质量保证能在多大程度上改善仍有待观察,但从业者理解生物测量误差如何影响小于和大于胎龄儿的预测是重要的第一步。

研究设计与样本

  • 测量误差标准差取自既往采用标准化测量方案并结合定性和定量质量控制监测的大型胎儿生物测量研究。
  • 确定使估计胎儿体重位于第10和第90百分位的腹围、头围和股骨长典型组合。
  • 采用蒙特卡洛模拟研究检验测量误差对胎儿估计胎儿体重高于或低于第10和第90百分位分类的影响。

主要发现

  • 误差假设服从高斯分布,均值为0 mm,腹围标准差6.93 mm、头围5.15 mm、股骨长1.38 mm。
  • 按此误差分布,使用第10和第90百分位筛查小于和大于胎龄儿时,检出率为78.0%,假阳性率4.7%。
  • 将 cut-off 放宽至第30和第70百分位,检出率升至98.2%,假阳性率升至24.2%。
  • 假设误差分布宽度减半,使用第10和第90百分位筛查时,检出率为86.6%,假阳性率2.3%。
  • 将 cut-off 放宽至第15和第85百分位,检出率升至97.0%,假阳性率升至6.3%。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: First, to obtain measurement-error models for biometric measurements of fetal abdominal circumference (AC), head circumference (HC) and femur length (FL), and, second, to examine the impact of biometric measurement error on sonographic estimated fetal weight (EFW) and its effect on the prediction of small- (SGA) and large- (LGA) for-gestational-age fetuses with EFW < 10th and > 90th percentile, respectively. METHODS: Measurement error standard deviations for fetal AC, HC and FL were obtained from a previous large study on fetal biometry utilizing a standardized measurement protocol and both qualitative and quantitative quality-control monitoring. Typical combinations of AC, HC and FL that gave EFW on the 10th and 90th percentiles were determined. A Monte-Carlo simulation study was carried out to examine the effect of measurement error on the classification of fetuses as having EFW above or below the 10th and 90th percentiles. RESULTS: Errors were assumed to follow a Gaussian distribution with a mean of 0 mm and SDs, obtained from a previous well-conducted study, of 6.93 mm for AC, 5.15 mm for HC and 1.38 mm for FL. Assuming errors according to such distributions, when the 10th and 90th percentiles are used to screen for SGA and LGA fetuses, respectively, the detection rates would be 78.0% at false-positive rates of 4.7%. If the cut-offs were relaxed to the 30th and 70th percentiles, the detection rates would increase to 98.2%, but at false-positive rates of 24.2%. Assuming half of the spread in the error distribution, using the 10th and 90th percentiles to screen for SGA and LGA fetuses, respectively, the detection rates would be 86.6% at false-positive rates of 2.3%. If the cut-offs were relaxed to the 15th and 85th percentiles, respectively, the detection rates would increase to 97.0% and the false-positive rates would increase to 6.3%. CONCLUSIONS: Measurement error in fetal biometry causes substantial error in EFW, resulting in misclassification of SGA and LGA fetuses. The extent to which improvement can be achieved through effective quality assurance remains to be seen but, as a first step, it is important for practitioners to understand how biometric measurement error impacts the prediction of SGA and LGA fetuses. © 2019 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Wright D, Wright A, Smith E, et al. Impact of biometric measurement error on identification of small- and large-for-gestational-age fetuses. Ultrasound Obstet Gynecol. 2020. PMID: 31682299. doi:10.1002/uog.21909

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。