文献速递产科

产程中进展角测量方法的比较及其对分娩结局的预测

Comparison of different methods of measuring angle of progression in prediction of labor outcome.
PubMed 文献 · Ultrasound Obstet Gynecol · 2020-01-01

前瞻性观察512例单胎引产孕妇,比较手动矢状面、旁矢状面及自动旁矢状面测量进展角(AoP)的可靠性。手动旁矢状面组内和组间ICC分别为0.97和0.96,可靠性最佳;自动旁矢状面19%无法捕获图像。联合母体因素与超声指标可解释54%阴道分娩时间变异,预测第一产程因产程进展失败(FTP)剖宫产模型AUC 0.80 vs 0.76。

要点

  • 手动旁矢状面测量AoP可靠性最佳,组内ICC 0.97,组间ICC 0.96。
  • 自动旁矢状面法在19%的病例中无法捕获图像。
  • 联合模型可解释54%阴道分娩时间变异,预测FTP剖宫产AUC 0.80。

核心结论

  • 手动旁矢状面技术是测量AoP可靠性最高的方法,未来研究应聚焦于此技术。
  • 结合母体因素、妊娠特征和超声发现的模型可解释超过一半的阴道分娩时间变异。
  • AoP对第一产程因FTP剖宫产的临床有用预测能力有限。

研究设计与样本

  • 前瞻性观察性研究,纳入512例单胎妊娠引产孕妇。
  • 随机选取50例存储图像评估手动矢状面、旁矢状面及自动旁矢状面测量AoP的组内和组间可靠性。
  • 阴道分娩者采用单因素线性、多因素线性及分位数回归分析预测分娩时间。
  • 采用单因素及多因素二项逻辑回归分析预测第一产程因FTP的剖宫产。

主要发现

  • 手动旁矢状面单观察者ICC为0.97(95%CI 0.95-0.98),两观察者ICC为0.96(95%CI 0.93-0.98),可靠性好。
  • 矢状面单观察者ICC为0.93(95%CI 0.88-0.96),两观察者ICC为0.74(95%CI 0.58-0.84),单观察者可靠性中等,两观察者间可靠性差。
  • Bland-Altman分析显示手动旁矢状面较矢状面在单观察者和两观察者中一致性界限均更窄。
  • 自动旁矢状面法在19%的病例中无法捕获图像。
  • 矢状面与手动旁矢状面AoP测量平均差值为11°。

关键数值与推荐

  • 手动旁矢状面单观察者ICC 0.97(95%CI 0.95-0.98),两观察者ICC 0.96(95%CI 0.93-0.98)。
  • 矢状面单观察者ICC 0.93(95%CI 0.88-0.96),两观察者ICC 0.74(95%CI 0.58-0.84)。
  • 自动旁矢状面法19%的病例无法捕获图像。
  • 矢状面与手动旁矢状面AoP测量平均差值为11°。
  • 预测第一产程因FTP剖宫产模型AUC 0.80 vs 0.76。

临床怎么用

  • 手动旁矢状面技术是测量AoP可靠性最高的方法,未来研究应聚焦于此技术。
  • AoP对第一产程因FTP剖宫产的临床有用预测能力有限。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: First, to compare the manual sagittal and parasagittal and automated parasagittal methods of measuring the angle of progression (AoP) by transperineal ultrasound during labor, and, second, to develop models for the prediction of time to delivery and need for Cesarean section (CS) for failure to progress (FTP) in a population of patients undergoing induction of labor. METHODS: This was a prospective observational study of transperineal ultrasound in a cohort of 512 women with a singleton pregnancy undergoing induction of labor. A random selection of 50 stored images was assessed for inter- and intraobserver reliability of AoP measurements using the manual sagittal and parasagittal and automated parasagittal methods. In cases of vaginal delivery, univariate linear, multiple linear and quantile regression analyses were performed to predict time to delivery. Univariate and multivariate binomial logistic regression analyses were performed to predict CS for FTP in the first stage of labor. RESULTS: The intraclass correlation coefficient (ICC) for the manual parasagittal method for a single observer was 0.97 (95% CI, 0.95-0.98) and for two observers it was 0.96 (95% CI, 0.93-0.98), indicating good reliability. The ICC for the sagittal method for a single observer was 0.93 (95% CI, 0.88-0.96) and for two observers it was 0.74 (95% CI, 0.58-0.84), indicating moderate reliability for a single observer and poor reliability between two observers. Bland-Altman analysis demonstrated narrower limits of agreement for the manual parasagittal approach than for the sagittal approach for both a single and two observers. The automated parasagittal method failed to capture an image in 19% of cases. The mean difference in AoP measurements between the sagittal and manual parasagittal methods was 11°. In pregnancies resulting in vaginal delivery, 54% of the variation in time to delivery was explained in a model combining parity, epidural and syntocinon use during labor and the sonographic findings of fetal head position and AoP. In the prediction of CS for FTP in the first stage of labor, a model which combined maternal factors with the sonographic measurements of AoP and estimated fetal weight was superior to one utilizing maternal factors alone (area under the receiver-operating-characteristics curve, 0.80 vs 0.76). CONCLUSIONS: First, the method of measuring AoP with the greatest reliability is the manual parasagittal technique and future research should focus on this technique. Second, over half of the variation in time to vaginal delivery can be explained by a model that combines maternal factors, pregnancy characteristics and ultrasound findings. Third, the ability of AoP to provide clinically useful prediction of CS for FTP in the first stage of labor is limited. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Frick A, Kostiv V, Vojtassakova D, et al. Comparison of different methods of measuring angle of progression in prediction of labor outcome. Ultrasound Obstet Gynecol. 2020. PMID: 31692170. doi:10.1002/uog.21913

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。