文献速递产科母胎医学

中孕期前置与低置胎盘的前瞻性队列随访超声研究

Follow-up ultrasound in second-trimester low-positioned anterior and posterior placentae: prospective cohort study.
PubMed 文献 · Ultrasound Obstet Gynecol · 2020-10-13

该前瞻性队列纳入958例孕18–24周胎盘低置(胎盘与宫颈内口距离IOD<20 mm)孕妇,评估中孕期IOD预测晚孕期胎盘低置的准确性。晚孕期48/958(5.0%)胎盘仍低置;中孕期前置胎盘者晚孕期低置风险显著高于低置胎盘者(RR 17.9)。作者建议将前壁低置胎盘随访IOD界值从20 mm降至5 mm。

要点

  • 中孕期前置胎盘者晚孕期低置风险显著高于低置胎盘者(RR 17.9,95%CI 8.9–36.0)。
  • 后壁胎盘晚孕期低置风险高于前壁(RR 2.4,95%CI 1.2–4.9)。
  • 有剖宫产史者晚孕期低置风险高于无剖宫产史者(RR 3.7,95%CI 1.9–7.2)。

核心结论

  • 在中孕期前壁低置胎盘病例中,将随访IOD界值从20 mm降至5 mm并确保所有前置胎盘孕妇接受随访超声,可减少不必要的随访超声而不遗漏高危孕妇。

研究设计与样本

  • 前瞻性队列研究,纳入孕18–24周经阴道超声检查发现胎盘低置(IOD<20 mm)的958例孕妇,所有孕妇均在晚孕期重新评估。

主要发现

  • 晚孕期48/958(5.0%)胎盘仍为低置。
  • 中孕期前置胎盘者晚孕期低置发生率37/181(20.4%),高于中孕期低置胎盘者的11/777(1.4%);RR 17.9(95%CI 8.9–36.0)。
  • 后壁胎盘者晚孕期低置发生率38/594(6.4%),高于前壁胎盘者的10/364(2.7%);RR 2.4(95%CI 1.2–4.9)。
  • 有剖宫产史者晚孕期低置发生率14/105(13.3%),高于无剖宫产史者的34/853(4.0%);RR 3.7(95%CI 1.9–7.2)。
  • 中孕期IOD识别晚孕期胎盘位置异常的界值:后壁胎盘为15.5 mm,前壁胎盘为-4.5 mm(即胎盘边缘覆盖宫颈内口4.5 mm)。

关键数值与推荐

  • 推荐将前壁低置胎盘随访的IOD界值从20 mm降至5 mm(作者建议,含5 mm安全边际)。

临床怎么用

  • 作者建议在中孕期前壁低置胎盘病例中采用5 mm作为随访IOD界值,并确保所有前置胎盘孕妇均接受随访超声。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The majority of cases of placenta previa or a low-lying placenta in the second trimester will have a normal placental position in the third trimester. The aim of this study was to assess the accuracy of the distance between the placenta and the internal os of the cervix (IOD) in the second trimester for the prediction of third-trimester low-positioned placenta, and to define a cut-off value at which all cases of third-trimester low-positioned placenta are identified. METHODS: This was a prospective cohort study including women undergoing a transvaginal ultrasound examination between 18 and 24 weeks' gestation who had a low-positioned placenta, defined as an IOD of < 20 mm. Low-positioned placenta included placenta previa, defined as a placenta covering the internal os of the cervix, and a low-lying placenta, defined as a placenta lying near to (within 20 mm) but not overlying the internal os. All women were re-evaluated in the third trimester. Relative risks for a low-positioned placenta in the third trimester were calculated for women with placenta previa vs a low-lying placenta, posterior vs anterior placenta and positive vs negative history of Cesarean section. Multilevel likelihood ratios for ranges of IOD in the prediction of a low-positioned placenta in the third trimester were calculated separately for anteriorly and posteriorly located placentae. Corresponding receiver-operating-characteristics curves were constructed. RESULTS: In total, 958 women were included in the study. In the second trimester, placentae were more frequently located on the posterior side (62.0%) than on the anterior side (38.0%). In the third trimester, 48/958 (5.0%) placentae persisted as a low-positioned placenta. Women with placenta previa in the second trimester had a higher risk of a low-positioned placenta in the third trimester than did those with a low-lying placenta in the second trimester (37/181 (20.4%) vs 11/777 (1.4%); relative risk (RR), 17.9 (95% CI, 8.9-36.0)). Women with a posterior placenta had a higher risk of a low-positioned placenta in the third trimester than did those with an anterior placenta (38/594 (6.4%) vs 10/364 (2.7%); RR, 2.4 (95% CI, 1.2-4.9)), as did women with a history of Cesarean section compared with those without such a history (14/105 (13.3%) vs 34/853 (4.0%); RR, 3.7 (95% CI, 1.9-7.2)). The cut-off value of IOD in the second trimester to identify all cases of an abnormally located placenta in the third trimester was 15.5 mm for posteriorly located placentae, while for anteriorly located placentae the IOD cut-off was lower, namely -4.5 mm, representing a 4.5-mm overlap of the placental edge over the internal os of the cervix. CONCLUSIONS: With incorporation of a safety margin of 5 mm and ensuring that all women with placenta previa undergo a follow-up scan, we recommend lowering the IOD cut-off value for follow-up in cases of an anterior low-positioned placenta from 20 to 5 mm, which would decrease the number of unnecessary follow-up ultrasound examinations without missing any high-risk women. © 2019 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Jansen CHJR, Kleinrouweler CE, Kastelein AW, et al. Follow-up ultrasound in second-trimester low-positioned anterior and posterior placentae: prospective cohort study. Ultrasound Obstet Gynecol. 2020. PMID: 31671480. doi:10.1002/uog.21903

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。